RESULTS OF THE MODERNIZATION OF THE ELECTROSTATIC PRECIPITATOR AT UNIT B1 OF THE THERMAL POWER PLANT KOSTOLAC B

被引:4
作者
Eric, Milic D. [1 ]
Stefanovic, Predrag L. J. [1 ]
Markovic, Zoran J. [1 ]
Jovanovic, Rastko D. [1 ]
Lazovic, Ivan M. [1 ]
Zivkovic, Nikola V. [1 ]
Ilic, Zeljko S. [2 ]
机构
[1] Univ Belgrade, Vinca Inst Nucl Sci, Belgrade, Serbia
[2] Publ Enterprise Elect Power Ind Serbia, Thermal Power Plant Kostolac B, Kostolac, Serbia
来源
THERMAL SCIENCE | 2018年 / 22卷
关键词
emission; electrostatic precipitator; particulate matter; modernization; EFFICIENCY;
D O I
10.2298/TSCI18S5623E
中图分类号
O414.1 [热力学];
学科分类号
摘要
The electrostatic precipitator system of the lignite fired 350 MWe unit BI of Thermal Power Plant Kostolac B has been modernized during 2014. The results of complex in site measurements, performed in the frame of performance control test at the beginning of the exploitation period of the upgraded electrostatic precipitator proved that, under normal and guarantee working conditions of the boiler and precipitator, the emission of particulate matter do not exceed limiting value. After the period of precipitator further adjustments, five series of measurements in the frame of acceptance test were performed in accordance with relevant standards. This paper presents results of the investigation of particulate matter concentration, laboratory analysis of the lignite, fly and bottom ash samples, working parameters of the unit and upgraded electrostatic precipitator as well as results of the calculations. The averaged mean particulate concentration at the exit of upgraded electrostatic precipitator of the unit BI during Acceptance test was below guaranteed value. It is confirmed that adjustments of electrostatic precipitator electrical parameters have improved electrostatic precipitator efficiency, as well that electrostatic precipitatorcould work highly efficiently in energy save mode with lower power consumption.
引用
收藏
页码:S1623 / S1634
页数:12
相关论文
共 22 条
[1]  
Back A., 2013, P INT S ICESP
[2]  
Deutsch W., 1992, ANN PHYS, V373, P335
[3]  
Eric M., 2015, P 17 S THERM SCI ENG, P569
[4]  
Eric M, 2011, P 15 S THERM SCI ENG, P568
[5]  
Erie M., 2013, P 16 S THERM SCI ENG, P750
[6]  
Gavric M., 2009, The Green Book of the Electric Power Industry of Serbia
[7]   Influence of the inlet velocity profiles on the prediction of velocity distribution inside an electrostatic precipitator [J].
Haque, Shah M. E. ;
Rasul, M. G. ;
Khan, M. M. K. ;
Deev, A. V. ;
Subaschandar, N. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2009, 33 (02) :322-328
[8]  
Jedrusik Maria, 2017, Przeglad Elektrotechniczny, V93, P228, DOI 10.15199/48.2017.02.50
[9]   Experimental study of electrostatic precipitator performance and comparison with existing theoretical prediction models [J].
Kim, SH ;
Lee, KW .
JOURNAL OF ELECTROSTATICS, 1999, 48 (01) :3-25
[10]  
LAGARIAS J S, 1963, J Air Pollut Control Assoc, V13, P595