Lung cancers missed on chest radiographs: Results obtained with a commercial computer-aided detection program

被引:47
作者
Li, Feng [1 ]
Engelmann, Roger [1 ]
Metz, Charles E. [1 ]
Doi, Kunio [1 ]
MacMahon, Heber [1 ]
机构
[1] Univ Chicago, Dept Radiol, Kurt Rossmann Labs Radiol Image Res, Chicago, IL 60637 USA
关键词
D O I
10.1148/radiol.2461061848
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To retrospectively determine the sensitivity of and number of false-positive marks made by a commercially available computer-aided detection (CAD) system for identifying lung cancers previously missed on chest radiographs by radiologists, with histopathologic results as the reference standard. Materials and Methods: Institutional review board approval was obtained for this HIPAA-compliant study; the requirement for informed patient consent was waived. A CAD nodule detection program was applied to 34 posteroanterior digital chest radiographs obtained in 34 patients (21 men, 13 women; mean age, 69 years). All 34 radiographs showed a nodular lung cancer that was apparent in retrospect but had not been mentioned in the report. Two radiologists identified these radiologist-missed cancers on the chest radiographs and graded them for visibility, location, subtlety (extremely subtle to extremely obvious on a 10-point scale), and actionability (actionable or not actionable according to whether the radiologists probably would have recommended follow-up if the nodule had been detected). The CAD results were analyzed to determine the numbers of cancers and false-positive nodules marked and to correlate the CAD results with the nodule grades for subtlety and actionability. The chi(2) test or Fisher exact test for independence was used to compare CAD sensitivity between the very subtle (grade 1-3) and relatively obvious (grade > 3) cancers and between the actionable and not actionable cancers. Results: The CAD program had an overall sensitivity of 35% (12 of 34 cancers), identifying seven (30%) of 23 very subtle and five (45%) of 11 relatively obvious radiologist-missed cancers (P = .21) and detecting two (25%) of eight missed not actionable and ten (38%) of 26 missed actionable cancers (P = .33). The CAD program made an average of 5.9 false-positive marks per radiograph. Conclusion: The described CAD system can mark a substantial proportion of visually subtle lung cancers that are likely to be missed by radiologists. (c) RSNA, 2008.
引用
收藏
页码:273 / 280
页数:8
相关论文
共 26 条
[1]  
[Anonymous], 1981, STAT METHODS RATES P
[2]   MISSED BRONCHOGENIC-CARCINOMA - RADIOGRAPHIC FINDINGS IN 27 PATIENTS WITH A POTENTIALLY RESECTABLE LESION EVIDENT IN RETROSPECT [J].
AUSTIN, JHM ;
ROMNEY, BM ;
GOLDSMITH, LS .
RADIOLOGY, 1992, 182 (01) :115-122
[3]   Digital chest radiography: Effect of temporal subtraction images on detection accuracy [J].
Difazio, MC ;
MacMahon, H ;
Xu, XW ;
Tsai, P ;
Shiraishi, J ;
Armato, SG ;
Doi, K .
RADIOLOGY, 1997, 202 (02) :447-452
[4]   CALCIFICATION IN PULMONARY NODULES - DETECTION WITH DUAL-ENERGY DIGITAL RADIOGRAPHY [J].
FRASER, RG ;
HICKEY, NM ;
NIKLASON, LT ;
SABBAGH, EA ;
LUNA, RF ;
ALEXANDER, CB ;
ROBINSON, CA ;
KATZENSTEIN, ALA ;
BARNES, GT .
RADIOLOGY, 1986, 160 (03) :595-601
[5]  
Freedman Matthew, 2004, Thorac Surg Clin, V14, P43, DOI 10.1016/S1547-4127(04)00036-2
[6]   Computer-aided detection performance in mammographic examination of masses: Assessment [J].
Gur, D ;
Stalder, JS ;
Hardesty, LA ;
Zheng, B ;
Sumkin, JH ;
Chough, DM ;
Shindel, BE ;
Rockette, HE .
RADIOLOGY, 2004, 233 (02) :418-423
[7]  
Hays W. L., 1988, STATISTICS, P410
[8]   NON-SMALL-CELL LUNG-CANCER - RESULTS OF THE NEW-YORK SCREENING-PROGRAM [J].
HEELAN, RT ;
FLEHINGER, BJ ;
MELAMED, MR ;
ZAMAN, MB ;
PERCHICK, WB ;
CARAVELLI, JF ;
MARTINI, N .
RADIOLOGY, 1984, 151 (02) :289-293
[9]   Computer-aided detection output on 172 subtle findings on normal mammograms previously obtained in women with breast cancer detected at follow-up screening mammography [J].
Ikeda, DM ;
Birdwell, RL ;
O'Shaughnessy, KF ;
Sickles, EA ;
Brenner, RJ .
RADIOLOGY, 2004, 230 (03) :811-819
[10]   ONE-SHOT DUAL-ENERGY SUBTRACTION CHEST IMAGING WITH COMPUTED RADIOGRAPHY - CLINICAL-EVALUATION OF FILM IMAGES [J].
ISHIGAKI, T ;
SAKUMA, S ;
IKEDA, M .
RADIOLOGY, 1988, 168 (01) :67-72