A quantitative comparison of the capabilities of in situ computed tomography and conventional computed tomography for damage analysis of composites

被引:51
作者
Boehm, R. [1 ]
Stiller, J. [1 ]
Behnisch, T. [1 ]
Zscheyge, M. [1 ]
Protz, R. [1 ]
Radloff, S. [1 ]
Gude, M. [1 ]
Hufenbach, W. [1 ]
机构
[1] Tech Univ Dresden, Inst Lightweight Engn & Polymer Technol, D-01307 Dresden, Germany
关键词
Textile composites; Fracture; Non-destructive testing; In situ computed tomography; ULTRASONIC EVALUATION; ANISOTROPIC DAMAGE; FATIGUE DAMAGE; FAILURE; BEHAVIOR;
D O I
10.1016/j.compscitech.2015.01.020
中图分类号
TB33 [复合材料];
学科分类号
摘要
The so called in situ computed tomography is a powerful non-destructive testing method to study the damage phenomenology while a material is loaded. However, the difference in the detected amount of damage compared to conventional CT scans after unloading of the specimen has not been reported so far and is therefore the focus of this study. Three different textile-reinforced composite materials have been experimentally investigated for that purpose. Carbon fibre reinforced epoxy composites with multi-layered flat bed weft-knitted fabrics and multi-axial non-crimp fabrics were uniaxially loaded in tension. In situ CT scans were taken at different load levels and conventional CT scans after unloading. The experiments have shown that the observed crack lengths and delaminated areas are significantly larger while the load is applied because of crack closure effects during unloading. Any damage diagnosis should therefore be performed under load. A ceramic C/C composite with woven reinforcement was taken as a third example. This composite was loaded by compression in thickness direction. It was found that the decrease of total porosity with increasing load can only be predicted by in situ CT measurements. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [41] Damage accumulation in a carbon/epoxy composite: Comparison between a multiscale model and computed tomography experimental results
    Scott, A. E.
    Sinclair, I.
    Spearing, S. M.
    Thionnet, A.
    Bunsell, A. R.
    COMPOSITES PART A-APPLIED SCIENCE AND MANUFACTURING, 2012, 43 (09) : 1514 - 1522
  • [42] Investigation of Targeted Process Control for Adjusting the Macrostructure of Freeze Foams Using In Situ Computed Tomography
    Maier, Johanna
    Geske, Vinzenz
    Werner, David
    Behnisch, Thomas
    Ahlhelm, Matthias
    Moritz, Tassilo
    Michaelis, Alexander
    Gude, Maik
    CERAMICS-SWITZERLAND, 2022, 5 (03): : 269 - 280
  • [43] Damage Characterization of Repeatedly Impacted Glass Fiber Reinforced Polyester-Armor Steel Composites With Cone Beam Computed Tomography Technique
    Fidan, Sinan
    Bora, Mustafa Ozgur
    Coban, Onur
    Tuna, Volkan
    POLYMER COMPOSITES, 2016, 37 (02) : 583 - 593
  • [44] Computed tomography in the evaluation of the equine head
    Kinns, J.
    Pease, A.
    EQUINE VETERINARY EDUCATION, 2009, 21 (06) : 291 - 294
  • [45] Neutron computed tomography of rat lungs
    Metzke, R. W.
    Runck, H.
    Stahl, C. A.
    Schillinger, B.
    Calzada, E.
    Muehlbauer, M.
    Schulz, M.
    Schneider, M.
    Priebe, H-J
    Wall, W. A.
    Guttmann, J.
    PHYSICS IN MEDICINE AND BIOLOGY, 2011, 56 (01) : N1 - N10
  • [46] Evaluation of the pore morphology formation of the Freeze Foaming process by in situ computed tomography
    Ahlhelm, Matthias
    Werner, David
    Maier, Johanna
    Abel, Johannes
    Behnisch, Thomas
    Moritz, Tassilo
    Michaelis, Alexander
    Gude, Maik
    JOURNAL OF THE EUROPEAN CERAMIC SOCIETY, 2018, 38 (09) : 3369 - 3378
  • [47] Comparison of cross-sectional anatomy and computed tomography of the tarsus in horses
    Raes, Els V.
    Bergman, Eric H. J.
    van der Veen, Henk
    Vanderperren, Katrien
    Van der Vekens, Elke
    Saunders, Jimmy H.
    AMERICAN JOURNAL OF VETERINARY RESEARCH, 2011, 72 (09) : 1209 - 1221
  • [48] Characterization of carbon fiber distribution in cement-based composites by Computed Tomography
    Gao, Jie
    Sha, Aimin
    Wang, Zhenjun
    Hu, Liqun
    Yun, Di
    Liu, Zhuangzhuang
    Huang, Yue
    CONSTRUCTION AND BUILDING MATERIALS, 2018, 177 : 134 - 147
  • [49] A comparative study on the use of ultra-low dose computed tomography scans with conventional computed tomography scans for the evaluation of proximal tibia intra-articular fractures
    Shetty, Harshit Bhaskar
    Joe, Varghese
    Mane, Prajwal
    Savur, Amarnath D.
    Mahesan, Harish
    Nazeer, Muhammed Ehsan
    JOURNAL OF ORTHOPAEDICS, 2023, 46 : 90 - 94
  • [50] Comparison of Radiography and Computed Tomography for Determining Tracheal Diameter and Length in Dogs
    Montgomery, James E.
    Mathews, Kyle G.
    Marcellin-Little, Denis J.
    Hendrick, Steve
    Brown, James C.