A quantitative comparison of the capabilities of in situ computed tomography and conventional computed tomography for damage analysis of composites

被引:51
作者
Boehm, R. [1 ]
Stiller, J. [1 ]
Behnisch, T. [1 ]
Zscheyge, M. [1 ]
Protz, R. [1 ]
Radloff, S. [1 ]
Gude, M. [1 ]
Hufenbach, W. [1 ]
机构
[1] Tech Univ Dresden, Inst Lightweight Engn & Polymer Technol, D-01307 Dresden, Germany
关键词
Textile composites; Fracture; Non-destructive testing; In situ computed tomography; ULTRASONIC EVALUATION; ANISOTROPIC DAMAGE; FATIGUE DAMAGE; FAILURE; BEHAVIOR;
D O I
10.1016/j.compscitech.2015.01.020
中图分类号
TB33 [复合材料];
学科分类号
摘要
The so called in situ computed tomography is a powerful non-destructive testing method to study the damage phenomenology while a material is loaded. However, the difference in the detected amount of damage compared to conventional CT scans after unloading of the specimen has not been reported so far and is therefore the focus of this study. Three different textile-reinforced composite materials have been experimentally investigated for that purpose. Carbon fibre reinforced epoxy composites with multi-layered flat bed weft-knitted fabrics and multi-axial non-crimp fabrics were uniaxially loaded in tension. In situ CT scans were taken at different load levels and conventional CT scans after unloading. The experiments have shown that the observed crack lengths and delaminated areas are significantly larger while the load is applied because of crack closure effects during unloading. Any damage diagnosis should therefore be performed under load. A ceramic C/C composite with woven reinforcement was taken as a third example. This composite was loaded by compression in thickness direction. It was found that the decrease of total porosity with increasing load can only be predicted by in situ CT measurements. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:62 / 68
页数:7
相关论文
共 50 条
  • [31] Analysis of sintered polymer scaffolds using concomitant synchrotron computed tomography and in situ mechanical testing
    Dhillon, A.
    Schneider, P.
    Kuhn, G.
    Reinwald, Y.
    White, L. J.
    Levchuk, A.
    Rose, F. R. A. J.
    Mueller, R.
    Shakesheff, K. M.
    Rahman, C. V.
    JOURNAL OF MATERIALS SCIENCE-MATERIALS IN MEDICINE, 2011, 22 (12) : 2599 - 2605
  • [32] Cryogenic damage mechanisms of CFRP laminates based on in-situ X-ray computed tomography characterization
    Li, Yuanchen
    Meng, Jinxin
    Niu, Guohao
    Yang, Heng
    Wang, Panding
    Lei, Hongshuai
    Fang, Daining
    COMPOSITES SCIENCE AND TECHNOLOGY, 2024, 247
  • [33] Microstructural analysis using X-ray computed tomography (CT) in flax/epoxy composites
    Kersani, M.
    Lomov, S. V.
    Van Vuure, A. W.
    Bouabdallah, A.
    Verpoest, I.
    37th Riso International Symposium on Materials Science, 2016, 139
  • [34] Diagnostic performance of mobile cone beam computed tomography versus conventional multi-detector computed tomography in orbital floor fractures: a study on human specimens
    Lacagne, A. S.
    Brumpt, E.
    Barrabe, A.
    Pomero, E.
    Chatelain, B.
    Grillet, F.
    Weber, E.
    Malakhia, A.
    Pons, M.
    Aubry, S.
    Meyer, C.
    Sigaux, N.
    Louvrier, A.
    INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2021, 50 (02) : 205 - 211
  • [35] Quantitative 3-Dimensional Computed Tomography Measurements of Coronoid Fractures
    Mellema, Jos J.
    Janssen, Stein J.
    Guitton, Thierry G.
    Ring, David
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (03): : 526 - 533
  • [36] IN VIVO MEASUREMENTS OF CORTICAL THICKNESS AND POROSITY AT THE PROXIMAL THIRD OF THE TIBIA USING GUIDED WAVES: COMPARISON WITH SITE-MATCHED PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY AND DISTAL HIGH-RESOLUTION PERIPHERAL QUANTITATIVE COMPUTED TOMOGRAPHY
    Schneider, Johannes
    Ramiandrisoa, Donatien
    Armbrecht, Gabriele
    Ritter, Zully
    Felsenberg, Dieter
    Raum, Kay
    Minonzio, Jean-Gabriel
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2019, 45 (05) : 1234 - 1242
  • [37] Diagnostic accuracy of cone beam computed tomography and conventional multislice spiral tomography in sheep mandibular condyle fractures
    Sirin, Y.
    Guven, K.
    Horasan, S.
    Sencan, S.
    DENTOMAXILLOFACIAL RADIOLOGY, 2010, 39 (06) : 336 - 342
  • [38] Classification of women with and without hip fracture based on quantitative computed tomography and finite element analysis
    K. K. Nishiyama
    M. Ito
    A. Harada
    S. K. Boyd
    Osteoporosis International, 2014, 25 : 619 - 626
  • [39] Localized Damage Analysis of Cement Mortar Using X-ray Computed Tomography In Situ Compressive Loading and Digital Volume Correlation
    Li, Na
    Zhao, Yanru
    Xing, Yongming
    He, Xiaoyan
    APPLIED SCIENCES-BASEL, 2023, 13 (06):
  • [40] Classification of women with and without hip fracture based on quantitative computed tomography and finite element analysis
    Nishiyama, K. K.
    Ito, M.
    Harada, A.
    Boyd, S. K.
    OSTEOPOROSIS INTERNATIONAL, 2014, 25 (02) : 619 - 626