Tailored Target Ablation Index Guided Pulmonary Vein Isolation in Treating Paroxysmal Atrial Fibrillation: A Single Center Randomized Study in Asian Population (AI-Asian-I)

被引:3
|
作者
Xiong, Qingsong [1 ]
Liao, Jia [1 ]
Chen, Weijie [1 ]
Xiao, Peilin [1 ]
Du, Huaan [1 ]
He, Qushuai [1 ]
Yin, Yuehui [1 ]
Ling, Zhiyu [1 ]
Chen, Shaojie [1 ,2 ]
机构
[1] Chongqing Med Univ, Dept Cardiol, Affiliated Hosp 2, Chongqing, Peoples R China
[2] Cardioangiol Centrum Bethanien CCB, Frankfurt, Germany
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2022年 / 9卷
关键词
atrial fibrillation; ablation index; pulmonary vein isolation; randomized; recurrence; CATHETER ABLATION;
D O I
10.3389/fcvm.2022.937913
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the efficacy and safety of lower ablation indexes (AI) guided pulmonary vein isolation (PVI) in treating paroxysmal atrial fibrillation (AF). Methods: Ninety patients with paroxysmal AF scheduled for radiofrequency ablation were randomly divided into three groups. The AI targets for PVI were as follows: In group A/B/C, 550/500/450 for roof and anterior wall, and 400/350/300 for posterior/inferior wall. The first-pass PVI rate, ablation time, complications and recurrence of atrial tachyarrhythmia (ATa) were compared. Results: The mean age was 62.5 years (male: 63.0%), mean body mass index (BMI): 24.35 & PLUSMN; 3.66 kg/m(2). The baseline characteristics were comparable. There was no significant difference in the first-pass PVI rate among the three groups (left-sided-PV: 66.7% vs. 80% vs. 73.3%, P = 0.51; right-sided-PV: 70% vs. 83.3% vs. 73.3%, P = 0.64), also with similar gap rate during the procedural waiting time. At 1-year follow-up there was no significant difference in the recurrence rate of ATa among the three groups (10% vs. 13.3% vs. 13.3%, P = 1.00). The ablation time in the Group C was significantly less than that in the other two groups (47.8 min. vs. 47.0 min. vs. 36.6 min, P < 0.001). Higher AI seemed to link a non-significant trend toward higher rate of pericardial effusion (group A + B vs. group C:6.7% vs. 0%, P = 0.30), although the rate of overall complications was not different among the three groups. Conclusion: This randomized study shows that, a relatively lower target AI guided ablation may be similarly effective to achieve PVI with significantly reduced ablation time and obtain similar clinical outcome in treating paroxysmal AF in Asian population.
引用
收藏
页数:9
相关论文
共 50 条
  • [21] Randomized Comparison Between Pulmonary Vein Antral Isolation versus Complex Fractionated Electrogram Ablation for Paroxysmal Atrial Fibrillation
    Chen, Minglong
    Yang, Bing
    Chen, Hongwu
    Ju, Weizhu
    Zhang, Fengxiang
    Tse, Hung-Fat
    Cao, Kejiang
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2011, 22 (09) : 973 - 981
  • [22] Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation-Paroxysmal Atrial Fibrillation: Is There Any Mystery in Pulmonary Vein Isolation?
    Ernst, Sabine
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (04)
  • [23] Ablation index-guided 50 W ablation for pulmonary vein isolation in patients with atrial fibrillation: Procedural data, lesion analysis, and initial results from the FAFA AI High Power Study
    Chen, Shaojie
    Schmidt, Boris
    Bordignon, Stefano
    Urbanek, Lukas
    Tohoku, Shota
    Bologna, Fabrizio
    Angelkov, Lazar
    Garvanski, Iskren
    Tsianakas, Nikolaos
    Konstantinou, Athanasios
    Trolese, Luca
    Weise, Felix
    Perrotta, Laura
    Chun, K. R. Julian
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2019, 30 (12) : 2724 - 2731
  • [24] Comparison of advanced generation cryoballoon ablation and ablation index-guided pulmonary vein isolation with non-pulmonary vein trigger induction test and additional ablation in paroxysmal atrial fibrillation
    Yasuyuki Egami
    Masami Nishino
    Hiroaki Nohara
    Shodai Kawanami
    Hiroki Sugae
    Kohei Ukita
    Akito Kawamura
    Hitoshi Nakamura
    Koji Yasumoto
    Masaki Tsuda
    Naotaka Okamoto
    Yasuharu Matsunaga-Lee
    Masamichi Yano
    Jun Tanouchi
    Journal of Interventional Cardiac Electrophysiology, 2023, 66 : 1571 - 1580
  • [25] Pulmonary vein isolation combined with superior vena cava isolation for atrial fibrillation ablation: a prospective randomized study
    Wang, Xin-Hua
    Liu, Xu
    Sun, Yu-Min
    Shi, Hai-Feng
    Zhou, Li
    Gu, Jia-Ning
    EUROPACE, 2008, 10 (05): : 600 - 605
  • [26] Radiofrequency Versus Cryoballoon Catheter Ablation for Paroxysmal Atrial Fibrillation: Durability of Pulmonary Vein Isolation and Effect on Atrial Fibrillation Burden The RACE-AF Randomized Controlled Trial
    Sorensen, Samuel K.
    Johannessen, Arne
    Worck, Rene
    Hansen, Morten L.
    Hansen, Jim
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2021, 14 (05) : 523 - 532
  • [27] Impact of Systematic Isolation of Superior Vena Cava in Addition to Pulmonary Vein Antrum Isolation on the Outcome of Paroxysmal, Persistent, and Permanent Atrial Fibrillation Ablation: Results from a Randomized Study
    Corrado, Andrea
    Bonso, Aldo
    Madalosso, Michela
    Rossillo, Antonio
    Themistoclakis, Sakis
    Di Biase, Luigi
    Natale, Andrea
    Raviele, Antonio
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2010, 21 (01) : 1 - 5
  • [28] A minimal or maximal ablation strategy to achieve pulmonary vein isolation for paroxysmal atrial fibrillation: a prospective multi-centre randomized controlled trial (the Minimax study)
    McLellan, Alex J. A.
    Ling, Liang-Han
    Azzopardi, Sonia
    Lee, Geraldine A.
    Lee, Geoffrey
    Kumar, Saurabh
    Wong, Michael C. G.
    Walters, Tomos E.
    Lee, Justin M.
    Looi, Khang-Li
    Halloran, Karen
    Stiles, Martin K.
    Lever, Nigel A.
    Fynn, Simon P.
    Heck, Patrick M.
    Sanders, Prashanthan
    Morton, Joseph B.
    Kalman, Jonathan M.
    Kistler, Peter M.
    EUROPEAN HEART JOURNAL, 2015, 36 (28) : 1812 - 1821
  • [29] Efficacy of the optimal ablation index–targeted strategy for pulmonary vein isolation in patients with atrial fibrillation: the OPTIMUM study results
    So-Ryoung Lee
    Eue-Keun Choi
    Eui-Jae Lee
    Won-Seok Choe
    Myung-Jin Cha
    Seil Oh
    Journal of Interventional Cardiac Electrophysiology, 2019, 55 : 171 - 181
  • [30] Multielectrode Pulmonary Vein Isolation Versus Single Tip Wide Area Catheter Ablation for Paroxysmal Atrial Fibrillation: A Multinational Multicenter Randomized Clinical Trial
    Boersma, Lucas V.
    van der Voort, Pepijn
    Debruyne, Pilippe
    Dekker, Lukas
    Simmers, Tim
    Rossenbacker, Tom
    Balt, Jippe
    Wijffels, Maurits
    Degreef, Yves
    CIRCULATION-ARRHYTHMIA AND ELECTROPHYSIOLOGY, 2016, 9 (04)