Tailored Target Ablation Index Guided Pulmonary Vein Isolation in Treating Paroxysmal Atrial Fibrillation: A Single Center Randomized Study in Asian Population (AI-Asian-I)

被引:3
|
作者
Xiong, Qingsong [1 ]
Liao, Jia [1 ]
Chen, Weijie [1 ]
Xiao, Peilin [1 ]
Du, Huaan [1 ]
He, Qushuai [1 ]
Yin, Yuehui [1 ]
Ling, Zhiyu [1 ]
Chen, Shaojie [1 ,2 ]
机构
[1] Chongqing Med Univ, Dept Cardiol, Affiliated Hosp 2, Chongqing, Peoples R China
[2] Cardioangiol Centrum Bethanien CCB, Frankfurt, Germany
来源
FRONTIERS IN CARDIOVASCULAR MEDICINE | 2022年 / 9卷
关键词
atrial fibrillation; ablation index; pulmonary vein isolation; randomized; recurrence; CATHETER ABLATION;
D O I
10.3389/fcvm.2022.937913
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To evaluate the efficacy and safety of lower ablation indexes (AI) guided pulmonary vein isolation (PVI) in treating paroxysmal atrial fibrillation (AF). Methods: Ninety patients with paroxysmal AF scheduled for radiofrequency ablation were randomly divided into three groups. The AI targets for PVI were as follows: In group A/B/C, 550/500/450 for roof and anterior wall, and 400/350/300 for posterior/inferior wall. The first-pass PVI rate, ablation time, complications and recurrence of atrial tachyarrhythmia (ATa) were compared. Results: The mean age was 62.5 years (male: 63.0%), mean body mass index (BMI): 24.35 & PLUSMN; 3.66 kg/m(2). The baseline characteristics were comparable. There was no significant difference in the first-pass PVI rate among the three groups (left-sided-PV: 66.7% vs. 80% vs. 73.3%, P = 0.51; right-sided-PV: 70% vs. 83.3% vs. 73.3%, P = 0.64), also with similar gap rate during the procedural waiting time. At 1-year follow-up there was no significant difference in the recurrence rate of ATa among the three groups (10% vs. 13.3% vs. 13.3%, P = 1.00). The ablation time in the Group C was significantly less than that in the other two groups (47.8 min. vs. 47.0 min. vs. 36.6 min, P < 0.001). Higher AI seemed to link a non-significant trend toward higher rate of pericardial effusion (group A + B vs. group C:6.7% vs. 0%, P = 0.30), although the rate of overall complications was not different among the three groups. Conclusion: This randomized study shows that, a relatively lower target AI guided ablation may be similarly effective to achieve PVI with significantly reduced ablation time and obtain similar clinical outcome in treating paroxysmal AF in Asian population.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] Efficacy of ablation index-guided pulmonary vein isolation in patients with paroxysmal atrial fibrillation
    Jiang, Ruhong
    Chen, Minglong
    Fan, Jie
    Yi, Fu
    Tang, Anli
    Liu, Xingpeng
    Zhu, Wenqing
    Liu, Shaowen
    Huang, Xiaobo
    Liu, Qiang
    Ju, Weizhu
    Zhang, Xi
    Li, Jie
    He, Jiangui
    Shi, Liang
    Zhou, Genqing
    Wang, Yuegang
    Fu, Guosheng
    Jiang, Chenyang
    PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2022, 45 (10): : 1186 - 1193
  • [2] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Kobayashi, Shuhei
    Fukaya, Hidehira
    Oikawa, Jun
    Saito, Daiki
    Sato, Tetsuro
    Matsuura, Gen
    Arakawa, Yuki
    Shirakawa, Yuki
    Nishinarita, Ryo
    Horiguchi, Ai
    Ishizue, Naruya
    Kishihara, Jun
    Niwano, Shinichi
    Ako, Junya
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 62 (01) : 123 - 131
  • [3] Adenosine-Guided Pulmonary Vein Antral Isolation for Paroxysmal Atrial Fibrillation: A Randomized Study
    Efremidis, Michael
    Letsas, Konstantinos P.
    Lioni, Louiza
    Vlachos, Konstantinos
    Georgopoulos, Stamatis
    Saplaouras, Athanasios
    Geladari, Eleni
    Giannopoulos, George
    Liu, Tong
    Deftereos, Spyridon
    Sideris, Antonios
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2016, 27 (11) : 1288 - 1292
  • [4] Pulmonary vein isolation guided by moderate ablation index targets combined with strict procedural endpoints for patients with paroxysmal atrial fibrillation
    Wang, Yan-Jiang
    Tian, Ying
    Shi, Liang
    Zeng, Li-Jun
    Xie, Bo-qia
    Li, Xue-xun
    Yang, Xin-Chun
    Liu, Xing-Peng
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2021, 32 (07) : 1842 - 1848
  • [5] Outcome of Circumferential Pulmonary Vein Isolation for Ablation of Atrial Fibrillation: A Single Center Experience
    Chen, Jien-Jiun
    Chiu, Fu-Chun
    Chua, Su-Kiat
    Yu, Chieh-Cheh
    Lin, Lian-Yu
    Tsai, Chia-Ti
    Lai, Ling-Ping
    Lin, Jiunn-Lee
    ACTA CARDIOLOGICA SINICA, 2013, 29 (05) : 457 - 461
  • [6] Rationale and study design for ablation of paroxysmal atrial fibrillation guided by ablation index: a multi-center, prospective randomized trial (PAF-AI trial)
    Jiang, Ruhong
    Chen, Minglong
    Fan, Jie
    Yi, Fu
    Tang, Anli
    Liu, Xingpeng
    Zhu, Wenqing
    Liu, Shaowen
    Huang, Xiaobo
    Ju, Weizhu
    Zhang, Xi
    Li, Jie
    He, Jiangui
    Shi, Liang
    Zhou, Genqing
    Wang, Yuegang
    Jiang, Chenyang
    JOURNAL OF INTERVENTIONAL CARDIAC ELECTROPHYSIOLOGY, 2021, 60 (03) : 439 - 444
  • [7] Extensive Posterior Wall Isolation on Top of Pulmonary Vein Isolation Guided by Ablation Index in Persistent Atrial Fibrillation Ablation
    Sabatino, Francesco
    Oriente, Domenico
    Fortunato, Fabrizio
    Cascino, Antonio
    Ferrara, Giuliano
    Sgarito, Giuseppe
    Conti, Sergio
    LIFE-BASEL, 2023, 13 (03):
  • [8] Rationale and study design for ablation of paroxysmal atrial fibrillation guided by ablation index: a multi-center, prospective randomized trial (PAF-AI trial)
    Ruhong Jiang
    Minglong Chen
    Jie Fan
    Fu Yi
    Anli Tang
    Xingpeng Liu
    Wenqing Zhu
    Shaowen Liu
    Xiaobo Huang
    Weizhu Ju
    Xi Zhang
    Jie Li
    Jiangui He
    Liang Shi
    Genqing Zhou
    Yuegang Wang
    Chenyang Jiang
    Journal of Interventional Cardiac Electrophysiology, 2021, 60 : 439 - 444
  • [9] Optimal interlesion distance in ablation index-guided pulmonary vein isolation for atrial fibrillation
    Shuhei Kobayashi
    Hidehira Fukaya
    Jun Oikawa
    Daiki Saito
    Tetsuro Sato
    Gen Matsuura
    Yuki Arakawa
    Yuki Shirakawa
    Ryo Nishinarita
    Ai Horiguchi
    Naruya Ishizue
    Jun Kishihara
    Shinichi Niwano
    Junya Ako
    Journal of Interventional Cardiac Electrophysiology, 2021, 62 : 123 - 131
  • [10] Does Electrogram Guided Substrate Ablation Add to the Success of Pulmonary Vein Isolation in Patients with Paroxysmal Atrial Fibrillation? A Prospective, Randomized Study
    Deisenhofer, Isabel
    Estner, Heidi
    Reents, Tilko
    Fichtner, Stephanie
    Bauer, Axel
    Wu, Jinjin
    Kolb, Christof
    Zrenner, Bernhard
    Schmitt, Claus
    Hessling, Gabriele
    JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2009, 20 (05) : 514 - 521