The detection of interturn short circuits in the stator windings of operating motors

被引:0
作者
Joksimovic, G [1 ]
Penman, J [1 ]
机构
[1] Univ Aberdeen, Dept Engn, Aberdeen AB24 3UE, Scotland
来源
IECON '98 - PROCEEDINGS OF THE 24TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, VOLS 1-4 | 1998年
关键词
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
The detection of shorted turns in stator winding is possible in a variety of ways. The analysis of the motor current to perform this function is particularly attractive however, since current sensors are usually installed together with the motor for control and protection purposes. A winding function based method for modelling polyphase cage induction motors with this type of asymmetry will developed in this submission, and it is shown that the stator winding itself can be used as a sensor for detection of this type of fault. An experimental setup comprising a 3kW delta connected motor loaded by a generator was used to validate this approach. The experimental results obtained clearly validated the theory.
引用
收藏
页码:1974 / 1979
页数:6
相关论文
共 50 条
[31]   Mechanical Response Before and After Rotor Interturn Short-circuit Fault on Stator Windings in Synchronous Generator [J].
Meng, Qingfa ;
He, Yuling .
2018 1ST IEEE STUDENT CONFERENCE ON ELECTRIC MACHINES AND SYSTEMS (IEEE SCEMS), 2018,
[32]   Detection of stator short circuits in VSI-fed brushless DC motors using wavelet transform [J].
Awadallah, MA ;
Morcos, MM ;
Gopalakrishnan, S ;
Nehl, TW .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2006, 21 (01) :1-8
[33]   An Analysis of the Impact of Rotor Winding Interturn Short Circuits on Turbine Generator Operating Variables [J].
Wu Yucai ;
Li Yonggang ;
Li Heming ;
Zhang Wenjing .
ELECTRIC POWER COMPONENTS AND SYSTEMS, 2015, 43 (06) :674-684
[34]   THE INFLUENCE OF COIL AND SURGE PARAMETERS ON TRANSIENT INTERTURN VOLTAGE DISTRIBUTION IN STATOR WINDINGS [J].
WRIGHT, MT ;
YANG, SJ ;
MCLEAY, K .
IEE PROCEEDINGS-B ELECTRIC POWER APPLICATIONS, 1983, 130 (04) :257-264
[35]   Detection of Stator Interturn Short-Circuit Faults in Inverter-Fed Induction Motors by Online Common-Mode Impedance Monitoring [J].
Zhao, Zhenyu ;
Fan, Fei ;
Wang, Wensong ;
Liu, Yong ;
See, Kye Yak .
IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2021, 70
[36]   Diagnosis of stator short circuits in brushless DC motors by monitoring phase voltages [J].
Awadallah, MA ;
Morcos, MM .
IEEE TRANSACTIONS ON ENERGY CONVERSION, 2005, 20 (01) :246-247
[37]   A novel method for induction motors stator interturn short circuit. fault diagnosis by wavelet packet analysis [J].
Tong, L ;
Jin, H .
ICEMS 2005: Proceedings of the Eighth International Conference on Electrical Machines and Systems, Vols 1-3, 2005, :2254-2258
[38]   On-line protection of electrical machines stator windings against interturn insulation failures [J].
Oraee, H .
EIGHTH INTERNATIONAL CONFERENCE ON ELECTRICAL MACHINES AND DRIVES, 1997, (444) :289-293
[39]   Detection of Interturn Short-Circuits of E-Bike BLDC motor [J].
Frank, Zdenek ;
Laksar, Jan .
IECON 2021 - 47TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2021,
[40]   Stator Winding InterTurn Short-Circuit Fault Detection in WRIM Using Rise and Fall Times of Stator Currents [J].
Bilal, Habachi ;
Dyagileva, Svetlana ;
Heraud, Nicolas ;
Sambatra, Eric Jean Roy ;
Ravelo, Blaise .
Progress In Electromagnetics Research C, 2024, 147 :109-116