A General Linear Relaxometry Model of R1 Using Imaging Data

被引:73
作者
Callaghan, Martina F. [1 ]
Helms, Gunther [2 ]
Lutti, Antoine [3 ]
Mohammadi, Siawoosh [1 ]
Weiskopf, Nikolaus [1 ]
机构
[1] UCL, Inst Neurol, Wellcome Trust Ctr Neuroimaging, London WC1N 3BG, England
[2] Univ Med Ctr, Dept Cognit Neurol, MR Res Neurol & Psychiat, Gottingen, Germany
[3] Univ Lausanne, CHUV, Dept Neurosci Clin, LREN, Lausanne, Switzerland
基金
英国惠康基金;
关键词
R-1; T-1; PD; PD*; MT; R-2*; T-2*; longitudinal relaxation; transverse relaxation; magnetization transfer; quantitative; 3T; water content; relaxometry; MAGNETIZATION-TRANSFER RATIO; HUMAN BRAIN; FIBER ORIENTATION; WATER-CONTENT; RELAXATION; FLASH; CONTRAST; IRON; SATURATION; RELAXIVITY;
D O I
10.1002/mrm.25210
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
PurposeThe longitudinal relaxation rate (R-1) measured in vivo depends on the local microstructural properties of the tissue, such as macromolecular, iron, and water content. Here, we use whole brain multiparametric in vivo data and a general linear relaxometry model to describe the dependence of R-1 on these components. We explore a) the validity of having a single fixed set of model coefficients for the whole brain and b) the stability of the model coefficients in a large cohort. MethodsMaps of magnetization transfer (MT) and effective transverse relaxation rate (R-2*) were used as surrogates for macromolecular and iron content, respectively. Spatial variations in these parameters reflected variations in underlying tissue microstructure. A linear model was applied to the whole brain, including gray/white matter and deep brain structures, to determine the global model coefficients. Synthetic R-1 values were then calculated using these coefficients and compared with the measured R-1 maps. ResultsThe model's validity was demonstrated by correspondence between the synthetic and measured R-1 values and by high stability of the model coefficients across a large cohort. ConclusionA single set of global coefficients can be used to relate R-1, MT, and R-2* across the whole brain. Our population study demonstrates the robustness and stability of the model. Magn Reson Med, 2014. (c) 2014 The Authors. Magnetic Resonance in Medicine published by Wiley Periodicals, Inc. Magn Reson Med 73:1309-1314, 2015. (c) 2014 Wiley Periodicals, Inc.
引用
收藏
页码:1309 / 1314
页数:6
相关论文
共 32 条
[1]   Unified segmentation [J].
Ashburner, J ;
Friston, KJ .
NEUROIMAGE, 2005, 26 (03) :839-851
[2]   The in vivo influence of white matter fiber orientation towards B0 on T2*in the human brain [J].
Bender, B. ;
Klose, U. .
NMR IN BIOMEDICINE, 2010, 23 (09) :1071-1076
[3]  
Connor JR, 1996, GLIA, V17, P83, DOI 10.1002/(SICI)1098-1136(199606)17:2<83::AID-GLIA1>3.0.CO
[4]  
2-7
[5]   In Vivo Functional and Myeloarchitectonic Mapping of Human Primary Auditory Areas [J].
Dick, Frederic ;
Tierney, Adam Taylor ;
Lutti, Antoine ;
Josephs, Oliver ;
Sereno, Martin I. ;
Weiskopf, Nikolaus .
JOURNAL OF NEUROSCIENCE, 2012, 32 (46) :16095-+
[6]   STUDIES OF GD-DTPA RELAXIVITY AND PROTON-EXCHANGE RATES IN TISSUE [J].
DONAHUE, KM ;
BURSTEIN, D ;
MANNING, WJ ;
GRAY, ML .
MAGNETIC RESONANCE IN MEDICINE, 1994, 32 (01) :66-76
[7]   Use of magnetic resonance imaging for in vivo measurements of water content in human brain: method and normal values [J].
Fatouros, PP ;
Marmarou, A .
JOURNAL OF NEUROSURGERY, 1999, 90 (01) :109-115
[8]   INVIVO BRAIN WATER DETERMINATION BY T1 MEASUREMENTS - EFFECT OF TOTAL WATER-CONTENT, HYDRATION FRACTION, AND FIELD-STRENGTH [J].
FATOUROS, PP ;
MARMAROU, A ;
KRAFT, KA ;
INAO, S ;
SCHWARZ, FP .
MAGNETIC RESONANCE IN MEDICINE, 1991, 17 (02) :402-413
[9]  
FULLERTON G D, 1982, Magnetic Resonance Imaging, V1, P209, DOI 10.1016/0730-725X(82)90172-2
[10]  
Gelman N, 2001, MAGNET RESON MED, V45, P71, DOI 10.1002/1522-2594(200101)45:1<71::AID-MRM1011>3.0.CO