Comparison of air displacement plethysmography with dual-energy X-ray absorptiometry and 3 field methods for estimating body composition in middle-aged men

被引:111
作者
Sardinha, LB
Lohman, TG
Teixeira, PJ
Guedes, DP
Going, SB
机构
[1] Univ Arizona, Dept Physiol, Body Composit Res Lab, Tucson, AZ 85721 USA
[2] Univ Tecn Lisboa, Fac Human Movement, Exercise & Hlth Lab, P-1100 Lisbon, Portugal
关键词
bioelectrical impedance analysis; BIA; bioelectrical impedance spectroscopy; dual-energy X-ray absorptiometry; DXA; air displacement plethysmography; percentage body fat; predictive accuracy; reliability; Portugal; men;
D O I
10.1093/ajcn/68.4.786
中图分类号
R15 [营养卫生、食品卫生]; TS201 [基础科学];
学科分类号
100403 ;
摘要
This study was designed to compare air displacement plethysmography with dual-energy X-ray absorptiometry (DXA) and 3 other field methods for estimation of body composition. Subjects were 62 healthy, white men aged 37.6 +/- 2.9 y (weight: 81.8 +/- 11.3 kg; height: 171.5 +/- 4.9 cm). Body composition was also assessed by using body mass index, single-frequency bioelectrical impedance analysis, multifrequency bioelectrical impedance spectroscopy, and the skinfold-thickness equations of Jackson and Pollock and Durnin and Womersley. Percentage body fat (%BF) with the plethysmograph was 23.4 +/- 7.0 and with DXA was 26.0 +/- 7.4. The 2.6% mean difference was significant (P < 0.05). Total error was 3.7%BF As assessed by multiple regression analysis, %BF with the plethysmograph, age, weight, and height yielded a DXA-adjusted R-2 value of 89.5% fat and an SEE of 2.4% fat. All other models had higher SEEs and lower adjusted R-2 values: 4.3% and 66.5% for body mass index, 3.3% and 79.8% for bioelectrical impedance analysis, 3.6% and 76.2% for bioelectrical impedance spectroscopy, 3.7% and 74.55% for the equations of Jackson and Pollock, and 3.9% and 71.6% for the equations of Durnin and Womersley, respectively. The plethysmograph also predicted fat mass and fat-free mass more accurately than all other models, with a lower SEE and higher adjusted R-2 value. In conclusion, although %BF was systematically underestimated, body composition was closely estimated with air displacement plethysmography in middle-aged men.
引用
收藏
页码:786 / 793
页数:8
相关论文
共 50 条
  • [41] DETECTION OF SMALL CHANGES IN BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    GOING, SB
    MASSETT, MP
    HALL, MC
    BARE, LA
    ROOT, PA
    WILLIAMS, DP
    LOHMAN, TG
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (06) : 845 - 850
  • [42] Comparison of bioelectrical impedance analysis and dual-energy X-ray absorptiometry for the assessment of appendicular body composition in anorexic women
    Bedogni, G
    Marra, M
    Bianchi, L
    Malavolti, M
    Nicolai, E
    De Filippo, E
    Scalfi, L
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2003, 57 (09) : 1068 - 1072
  • [43] Assessment of body composition in Indian adults: comparison between dual-energy X-ray absorptiometry and isotope dilution technique
    Kulkarni, Bharati
    Kuper, Hannah
    Taylor, Amy
    Wells, Jonathan C.
    Radhakrishna, K. V.
    Kinra, Sanjay
    Ben-Shlomo, Yoav
    Smith, George Davey
    Ebrahim, Shah
    Kurpad, A. V.
    Byrne, Nuala M.
    Hills, Andrew P.
    BRITISH JOURNAL OF NUTRITION, 2014, 112 (07) : 1147 - 1153
  • [44] Evaluation of air-displacement plethysmography and bioelectrical impedance analysis vs dual-energy X-ray absorptiometry for the assessment of fat-free mass in elderly subjects
    Bertoli, S.
    Battezzatti, A.
    Testolin, G.
    Bedogni, G.
    EUROPEAN JOURNAL OF CLINICAL NUTRITION, 2008, 62 (11) : 1282 - 1286
  • [45] Evaluation of air-displacement plethysmography and bioelectrical impedance analysis vs dual-energy X-ray absorptiometry for the assessment of fat-free mass in elderly subjects
    S Bertoli
    A Battezzati
    G Testolin
    G Bedogni
    European Journal of Clinical Nutrition, 2008, 62 : 1282 - 1286
  • [46] Comparison of bioelectrical impedance analysis and dual-energy X-ray absorptiometry for the assessment of appendicular body composition in anorexic women
    G Bedogni
    M Marra
    L Bianchi
    M Malavolti
    E Nicolai
    E De Filippo
    L Scalfi
    European Journal of Clinical Nutrition, 2003, 57 : 1068 - 1072
  • [47] Body composition measured by dual-energy X-ray absorptiometry half-body scans in obese children
    Breithaupt, P.
    Colley, R. C.
    Adamo, K. B.
    ACTA PAEDIATRICA, 2011, 100 (12) : E260 - E266
  • [48] ACCURACY OF MEASUREMENTS OF BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY INVIVO
    SVENDSEN, OL
    HAARBO, J
    HASSAGER, C
    CHRISTIANSEN, C
    AMERICAN JOURNAL OF CLINICAL NUTRITION, 1993, 57 (05) : 605 - 608
  • [49] COMPARATIVE-STUDY OF BODY-COMPOSITION BY DUAL-ENERGY X-RAY ABSORPTIOMETRY
    ALOIA, JF
    VASWANI, A
    MA, RM
    FLASTER, E
    JOURNAL OF NUCLEAR MEDICINE, 1995, 36 (08) : 1392 - 1397
  • [50] Body composition by dual-energy X-ray absorptiometry in patients with Crohn's disease
    Tjellesen, L
    Nielsen, PK
    Staun, M
    SCANDINAVIAN JOURNAL OF GASTROENTEROLOGY, 1998, 33 (09) : 956 - 960