Microfluidic chip-based nanoelectrode array as miniaturized biochemical sensing platform for prostate-specific antigen detection

被引:48
作者
Triroj, Napat [1 ]
Jaroenapibal, Papot [2 ]
Shi, Haibin [3 ,4 ]
Yeh, Joanne I. [3 ,4 ]
Beresford, Roderic [1 ]
机构
[1] Brown Univ, Div Engn, Providence, RI 02912 USA
[2] Univ Penn, Dept Mat Sci & Engn, Philadelphia, PA 19104 USA
[3] Univ Pittsburgh, Sch Med, Dept Biol Struct, Pittsburgh, PA 15213 USA
[4] Univ Pittsburgh, Sch Med, Dept Bioengn, Pittsburgh, PA 15213 USA
基金
美国国家卫生研究院; 美国国家科学基金会;
关键词
Nanoelectrode arrays; Microfluidic chip; Focused ion beam (FIB); Prostate-specific antigen (PSA) biosensor; Competitive immunoassay; MULTIPLE MICROELECTRODE ARRAYS; NANOMETER-SIZED ELECTRODES; CRYSTAL-STRUCTURE; DOUBLE-LAYER; ELECTROCHEMISTRY; VOLTAMMETRY; CANCER; PNA;
D O I
10.1016/j.bios.2010.11.039
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A microfluidic biosensor chip with an embedded three-electrode configuration is developed for the study of the voltammetric response of a nanoelectrode array with controlled inter-electrode distance in a nanoliter-scale sample volume. The on-chip three-electrode cell consists of a 5 x 5 array of Au working nanoelectrodes with radii between 60 and 120 nm, a Cl-2-plasma-treated Ag/AgCl reference electrode, and a Au counter electrode. The nanoelectrode array is fabricated by creating high-aspect-ratio pores through an alumina insulating layer using an I-2 gas-assisted focused-ion-beam (FIB) milling, ion beam sculpting, and electrodeposition of Au. The glass substrate with the electrode pattern is assembled with a polydirriethylsiloxane (PDMS) microchannel slab giving a volume of 180 nL for each channel. Cyclic voltammetry calibration with a standard redox species exhibits a significant increase of current density by two orders of magnitude compared to that obtained from a microelectrode. On-chip functionalization of the nanoelectrodes with a prostate-specific antigen (PSA) biosensor complex and detection of PSA based on a competitive immunoassay method are performed. The detection limit is approximately 10 pg/mL (similar to 270 fM), which corresponds to roughly 30,000 copies of PSA in the microchannel test volume. (C) 2010 Elsevier B.V. All rights reserved.
引用
收藏
页码:2927 / 2933
页数:7
相关论文
共 27 条
[1]  
Achim C, 2009, Patent No. [US20090061451, 20090061451, 2009/0061451]
[2]   IS CYCLIC VOLTAMMETRY ABOVE A FEW HUNDRED KILOVOLTS PER SECOND STILL CYCLIC VOLTAMMETRY [J].
AMATORE, C ;
LEFROU, C .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 1990, 296 (02) :335-358
[3]   Recent developments in dynamic electrochemical studies of adsorbed enzymes and their active sites [J].
Armstrong, FA .
CURRENT OPINION IN CHEMICAL BIOLOGY, 2005, 9 (02) :110-117
[4]   Nanoelectrodes, nanoelectrode arrays and their applications [J].
Arrigan, DWM .
ANALYST, 2004, 129 (12) :1157-1165
[5]  
Bard A.J., 1980, LR Faulkner electrochemical methods. Fundamentais and Applications
[6]  
Blijenberg BG, 1996, EUR J CLIN CHEM CLIN, V34, P817
[7]   Overestimation of heterogeneous rate constants of hexacyanoferrate at nanometer-sized ultramicroelectrodes [J].
Chen, JY ;
Aoki, K .
ELECTROCHEMISTRY COMMUNICATIONS, 2002, 4 (01) :24-29
[8]   The voltammetric response of nanometer-sized carbon electrodes [J].
Chen, SL ;
Kucernak, A .
JOURNAL OF PHYSICAL CHEMISTRY B, 2002, 106 (36) :9396-9404
[9]   PROSTATE-SPECIFIC ANTIGEN IN SCREENING OF PROSTATE-CANCER [J].
CHU, TM .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 1994, 8 (05) :323-326
[10]   ALUMINUM-OXIDE FILMS MADE FROM EVAPORATED SAPPHIRE [J].
GOSNEY, WM ;
MULLER, RS .
THIN SOLID FILMS, 1972, 14 (02) :255-266