Intra-thoracic tumor motion estimation from CT imaging using 3D optical flow method

被引:0
作者
Guerrero, T [1 ]
Zhang, G [1 ]
Huang, TC [1 ]
Liao, ZX [1 ]
Lin, KP [1 ]
机构
[1] Univ Texas, MD Anderson Canc Ctr, Div Radiat Oncol, Houston, TX 77030 USA
来源
Proceedings of the Second IASTED International Conference on Biomedical Engineering | 2004年
关键词
tumor motion; 3D optical flow; computed tomography; motion estimation;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Purpose: To develop and validate an automated method for intra-thoracic tumor motion estimation from respiratory gated CT imaging using 3D optical flow method (OFM). Materials and Methods: A deformable image registration algorithm using 3D OFM is modified to track user delineated tumor surfaces and volumes. The location of a tumor delineated on a reference CT volume is estimated on the target CT volume from the 3D OFM calculated displacement vectors. A thoracic phantom CT image volume with generated 1.2 and 2.4 cm displacements is used for validation of motion estimates. One esophagus and one lung cancer cases with inspiration and expiration breath-hold CT image volumes are input to a 3D thin-plate spline (TPS) algorithm to generate a ficticious known displacement for validation. The 3D OFM is applied to the exhalation and inhalation CT image sets. The resulting displacement vectors are applied to the tumor surface and content providing an estimate of tumor surface and volume motion. The root mean square error (rms) is calculated for the known displacements. Results: The displacements of the phantom tumor were 1.20 and 2.40 cm with full-width at tenth maximum (FWTM) of 0.008 and 0.006 cm respectively. The maximum error of any single voxel's motion estimate is 1.1 mm or approximately one third of the z-dimension voxel size. Comparison of the 3D TPS generated and the 3D OFM calculated displacements revealed a rms error less than 0.25 mm. For the patient cases, the respiratory displacement of the esophageal tumors was non-uniform and up to 1.4 cm. The esophagus tumor motion was greatest inferiorly. A lung tumor displacement of 2.4 cm was found in the case evaluated. The lung tumor motion was not uniform and deformation was noted. Conclusion: 3D OFM was shown to provide an accurate estimation of intra-thoracic tumor motion, with estimated errors less than the voxel dimension. Surprisingly esophageal tumor motion was large.
引用
收藏
页码:174 / 179
页数:6
相关论文
共 16 条
[1]   3-DIMENSIONAL CONFORMAL RADIATION-THERAPY MAY IMPROVE THE THERAPEUTIC RATIO OF HIGH-DOSE RADIATION-THERAPY FOR LUNG-CANCER [J].
ARMSTRONG, JG ;
BURMAN, C ;
LEIBEL, S ;
FONTENLA, D ;
KUTCHER, G ;
ZELEFSKY, M ;
FUKS, Z .
INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1993, 26 (04) :685-689
[2]  
CHERRY CPD, 2000, MED PHYS, V27, P1400
[3]  
Collier Dawn C, 2003, J Appl Clin Med Phys, V4, P17, DOI 10.1120/1.1521271
[4]   Dosimetric consequences of tumor mobility in radiotherapy of stage I non-small cell lung cancer - an analysis of data generated using 'slow' CT scans [J].
de Koste, JRV ;
Lagerwaard, FJ ;
Schuchhard-Schipper, RH ;
Nijssen-Visser, MRJ ;
Voet, PWJ ;
Oei, SS ;
Senan, S .
RADIOTHERAPY AND ONCOLOGY, 2001, 61 (01) :93-99
[5]  
FORSTER KM, 2003, IN PRESS INT J RAD O
[6]  
Gorce J M, 1997, Med Image Anal, V1, P245, DOI 10.1016/S1361-8415(97)85013-X
[7]   DETERMINING OPTICAL-FLOW [J].
HORN, BKP ;
SCHUNCK, BG .
ARTIFICIAL INTELLIGENCE, 1981, 17 (1-3) :185-203
[8]  
ICUR, 1999, Report 62
[9]  
KEALL PJ, 2003, UNPUB PHYS MED BIOL
[10]   Fiducial-based targeting accuracy for external-beam radiotherapy [J].
Murphy, MJ .
MEDICAL PHYSICS, 2002, 29 (03) :334-344