Conformable Row-Column Ultrasound Arrays for Abdominal Imaging

被引:0
|
作者
Lu, Jian-yu [1 ]
Jiang, Xiaoning [2 ]
机构
[1] Univ Toledo, Dept Bioengn, Ultrasound Lab, Toledo, OH 43606 USA
[2] North Carolina State Univ, MNEL, Raleigh, NC 27695 USA
关键词
2D arrays; row-column arrays; medical ultrasound imaging; artificial intelligence; camera positioning; minimal human interventions; ADDRESSED ARRAYS;
D O I
10.1109/ultsym.2019.8926153
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Fully-addressable two-dimensional (2D) array ultrasound transducers have issues such as a large number of elements, difficult to interconnect with an imaging system, high acoustic impedance of each array element which leads to a low signal-to-noise ratio (SNR), and high cost for medical ultrasound imaging systems, especially, for a 2D array of a size close to 300 mm by 300 mm with more than one million elements for imaging of a large area such as the abdomen of big patients and pregnant women. Despite the issues above, an array of a large size is necessary to reconstruct a large 3D volumetric image for artificial intelligent (AI) assisted medical diagnoses with minimal human interventions, which is especially desirable in countries or areas where there are few highly trained medical professionals to operate ultrasound imaging systems. To address the issues associated with large fully-addressable 2D array transducers, row-column (RC) arrays have been proposed to reduce the number of elements of the 2D arrays and reduce the acoustic impedance of each array element to increase SNR. Although a RC array can address some issues of the fully-addressable 2D arrays and simplify the imaging system greatly, the array must be rigid to avoid introducing phase aberrations due to deformation of the array. To solve the problem, in this paper, 36 sub-arrays of 25.6 mm by 25.6 mm each are proposed to form a large conformable RC array of a size of about 281.6 mm by 281.6 mm. To simplify the imaging system by further reducing the number of elements, a 25.6-mm gap filled with flexible materials between the sub-arrays is introduced. To cover the space between the sub-arrays in imaging, a 2D acoustic lens of 30 degrees divergence is applied to each sub-array. To determine the position of each sub-array in the space for image reconstruction, 3 markers are placed on each sub-array to allow a position-reading camera to determine the position of the sub-array. Computer simulation with limited-diffraction array beam method was performed to calculate the ultrasound fields produced by a sub-array and the results show that the beam width of each sub-array of 2.5-MHz center frequency is about 2.6 mm at a depth of 70 mm and 0 degrees steering angle. Thus, the pulse-echo beam dimension is about 2.6 mm by 2.6 mm in the plane that is perpendicular to the ultrasound wave propagation. This demonstrates that the proposed RC array is capable of 3D imaging of a large volume for AI-assisted medical diagnoses with minimal human intervention. Although, as compared to the fully-addressable 2D arrays, the RC arrays can only focus in one dimension in both transmission and reception, leading to lower image resolution and higher sidelobe (reduced image contrast), the proposed RC array is a good compromise and make it feasible for intelligent imaging of a large area such as the abdomen of big patients or pregnant women.
引用
收藏
页码:1753 / 1756
页数:4
相关论文
共 50 条
  • [1] Imaging Performance for Two Row-Column Arrays
    Bouzari, Hamed
    Engholm, Mathias
    Nikolov, Svetoslav Ivanov
    Stuart, Matthias Bo
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (07) : 1209 - 1221
  • [2] Anatomic and Functional Imaging Using Row-Column Arrays
    Jensen, Jorgen Arendt
    Schou, Mikkel
    Jorgensen, Lasse Thurmann
    Tomov, Borislav G.
    Stuart, Matthias Bo
    Traberg, Marie Sand
    Taghavi, Iman
    Oygaard, Sigrid Huesebo
    Ommen, Martin Lind
    Steenberg, Kitty
    Thomsen, Erik Vilain
    Panduro, Nathalie Sarup
    Nielsen, Michael Bachmann
    Sorensen, Charlotte Mehlin
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2022, 69 (10) : 2722 - 2738
  • [3] Acoustical cross-talk in row-column addressed 2-D transducer arrays for ultrasound imaging
    Christiansen, Thomas Lehrmann
    Jensen, Jorgen Arendt
    Thomsen, Erik Vilain
    ULTRASONICS, 2015, 63 : 174 - 178
  • [4] Beamformer for a Lensed Row-Column Array in 3-D Ultrasound Imaging
    Salari, Ali
    Audoin, Melanie
    Tomov, Borislav Gueorguiev
    Yiu, Billy Y. S.
    Thomsen, Erik Vilain
    Arendt Jensen, Jorgen
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2025, 72 (02) : 238 - 250
  • [5] Row-Column Addressed Arrays for Nondestructive Evaluation Applications
    Kirkpatrick, James P.
    Wilcox, Paul D.
    Smith, Robert A.
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2019, 66 (06) : 1119 - 1128
  • [6] ROW-COLUMN DISCRETE PHASING OF ANTENNA-ARRAYS
    ANTIPIN, AG
    ANTOSHKOVA, IM
    PUZANKOV, AF
    TELECOMMUNICATIONS AND RADIO ENGINEERING, 1986, 40-1 (12) : 117 - 119
  • [7] Volumetric Ultrasound Imaging with Row-Column Addressed 2-D Arrays Using Spatial Matched Filter Beamforming
    Bouzari, Hamed
    Engholm, Mathias
    Christiansen, Thomas Lehrmann
    Stuart, Matthias Bo
    Nikolov, Svetoslav Ivanov
    Thomsen, Erik Vilain
    Jensen, Jorgen Arendt
    2015 IEEE INTERNATIONAL ULTRASONICS SYMPOSIUM (IUS), 2015,
  • [8] ROW-COLUMN BEAMFORMER FOR FAST VOLUMETRIC IMAGING
    Jorgensen, Lasse Thurmann
    Praesius, Sebastian Kazmarek
    Panduro, Nathalie Sarup
    Andersen, Sofie Bech
    Sorensen, Charlotte Mehlin
    Jensen, Jorgen Arendt
    2023 IEEE INTERNATIONAL CONFERENCE ON ACOUSTICS, SPEECH, AND SIGNAL PROCESSING WORKSHOPS, ICASSPW, 2023,
  • [9] Row-Column Beamformer for Fast Volumetric Imaging
    Jorgensen, Lasse Thurmann
    Proesius, Sebastian Kazmarek
    Stuart, Matthias Bo
    Jensen, Jorgen Arendt
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2023, 70 (07) : 668 - 680
  • [10] Compensated Row-Column Ultrasound Imaging System Using Three Dimensional Random Fields
    Ben Daya, Ibrahim
    Chen, Albert I. H.
    Shafiee, Mohammad Javad
    Wong, Alexander
    Yeow, John T. W.
    IMAGE ANALYSIS AND RECOGNITION, ICIAR 2017, 2017, 10317 : 107 - 116