Arthroplasty of the proximal interphalangeal joint with the TACTYS® prosthesis: Preliminary results after a minimum follow-up of 2 years

被引:24
作者
Athlani, L. [1 ]
Gaisne, E. [1 ]
Bellemere, P. [1 ]
机构
[1] Inst Main Nantes Atlantique, 21 Rue Martyrs, F-44100 Nantes, France
关键词
Arthritis; Arthroplasty; Proximal interphalangeal joint; Hand surgery; Prosthesis; PYROLYTIC CARBON ARTHROPLASTY; SURFACE REPLACEMENT ARTHROPLASTY; FLEXIBLE IMPLANT ARTHROPLASTY; SILICONE ARTHROPLASTY; RESURFACING ARTHROPLASTY; POSTTRAUMATIC STIFFNESS; PYROCARBON IMPLANTS; SWANSON IMPLANT; FINGER JOINTS; OUTCOMES;
D O I
10.1016/j.hansur.2015.12.013
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The TACTYS (R) implant is a new anatomic gliding articular and modular prosthesis for the proximal interphalangeal (PIP) joint. We report preliminary results with a minimum follow-up of 2 years. Twenty-two patients with a mean age of 63 years were operated on at a single center by two senior hand surgeons. Indications were painful and stiff PIP joints. The joint damage was caused by osteoarthritis (18 cases), post-traumatic arthritis (3) and rheumatoid arthritis (1). All prostheses were implanted through a dorsal mid-line transtendinous approach. Postoperative active and passive range of motion in flexion and extension was performed immediately with a protective splint for 2 weeks. All patients were evaluated (pain, range of motion, strength, function, X-rays) with a mean follow-up of 34 months (range 24-50). Pain decreased from 6.5 preoperatively to 1.9 postoperatively on a VAS scale. Flexion-extension range of motion increased from 39 degrees preoperatively to 58 degrees postoperatively. Grip strength was 21 kg preoperatively and 25 kg postoperatively. Pinch strength was 3 kg preoperatively and 5 kg postoperatively. Functional QuickDASH and PRWE scores were significantly improved at the last follow-up. Four patients were reoperated on: dorsal tenoarthrolysis in 3 cases and volar osteophyte removal in 1 case. All implants were still in place at the last follow-up. On X-rays, there were no signs of implant migration or loosening. The modularity of the prosthesis seems to be this implant's greatest advantage. The TACTYS (R) prosthesis is a reliable alternative to other conventional PIP implants. (C) 2016 SFCM. Published by Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:168 / 178
页数:11
相关论文
共 48 条
[21]   LONG-TERM RESULTS OF PROXIMAL INTERPHALANGEAL JOINT RESECTION ARTHROPLASTIES WITH A SILICONE IMPLANT [J].
ISELIN, F ;
CONTI, E .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (03) :S95-S97
[22]   Surface Replacement Arthroplasty of the Proximal Interphalangeal Joint Using the PIP-SRA Implant: Results, Complications, and Revisions [J].
Jennings, Charles D. ;
Livingstone, Douglas P. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2008, 33A (09) :1565-1572
[23]   Surface Replacement Arthroplasty of the Proximal Interphalangeal Joint Using the SR PIP Implant: Long-Term Results [J].
Jennings, Charles D. ;
Livingstone, Douglas P. .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2015, 40 (03) :469-473
[24]   PROXIMAL INTERPHALANGEAL JOINT SILICONE REPLACEMENT ARTHROPLASTY - CLINICAL-RESULTS USING AN ANTERIOR APPROACH [J].
LIN, HH ;
WYRICK, JD ;
STERN, PJ .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1995, 20A (01) :123-132
[25]   Implant arthroplasty of the hand: Retrospective and prospective considerations [J].
Linscheid, RL .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2000, 25A (05) :796-816
[26]   Development of a surface replacement arthroplasty for proximal interphalangeal joints [J].
Linscheid, RL ;
Murray, PM ;
Vidal, MA ;
Beckenbaugh, RD .
JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 1997, 22A (02) :286-298
[27]   Patient rating of wrist pain and disability: A reliable and valid measurement tool [J].
MacDermid, JC ;
Turgeon, T ;
Richards, RS ;
Beadle, M ;
Roth, JH .
JOURNAL OF ORTHOPAEDIC TRAUMA, 1998, 12 (08) :577-586
[28]   Pyrolytic carbon arthroplasty for the proximal interphalangeal joint: results after minimum 3 years of follow-up [J].
Mashhadi, S. A. ;
Chandrasekharan, L. ;
Pickford, M. A. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (06) :501-505
[29]   Pyrocarbon proximal interphalangeal joint arthroplasty: outcomes of a cohort study [J].
McGuire, D. T. ;
White, C. D. ;
Carter, S. L. ;
Solomons, M. W. .
JOURNAL OF HAND SURGERY-EUROPEAN VOLUME, 2012, 37E (06) :490-496
[30]   Der Fingermittelgelenkersatz mit PyrocarbonprothesenProximal Interphalangeal Joint Replacement with Pyrolytic Carbon Prostheses [J].
Reinhard Meier ;
Matthias Schulz ;
Hermann Krimmer ;
Nikolas Stütz ;
Ulrich Lanz .
Operative Orthopädie und Traumatologie, 2007, 19 (1)