A general kinetic model for quantitative perfusion imaging with arterial spin labeling

被引:949
作者
Buxton, RB
Frank, LR
Wong, EC
Siewert, B
Warach, S
Edelman, RR
机构
[1] Univ Calif San Diego, Med Ctr, Dept Radiol, San Diego, CA 92103 USA
[2] Univ Calif San Diego, Dept Psychiat, San Diego, CA 92103 USA
[3] Beth Israel Hosp, Dept Radiol, Boston, MA 02215 USA
关键词
MRI; arterial spin labeling; perfusion; cerebral blood flow;
D O I
10.1002/mrm.1910400308
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Recently, several implementations of arterial spin labeling (ASL) techniques have been developed for producing MRI images sensitive to local tissue perfusion. For quantitation of perfusion, both pulsed and continuous labeling methods potentially suffer from a number of systematic errors. In this study, a general kinetic model for the ASL signal is described that can be used to assess these errors. With appropriate assumptions, the general model reduces to models that have been used previously to analyze ASL data, but the general model also provides a way to analyze the errors that result if these assumptions are not accurate. The model was used for an initial assessment of systematic errors due to the effects of variable transit delays from the tagging band to the imaging voxel, the effects of capillary/tissue exchange of water on the relaxation of the tag, and the effects of incomplete water extraction. In preliminary experiments with a human subject, the model provided a good description of pulsed ASL data during a simple sensorimotor activation task.
引用
收藏
页码:383 / 396
页数:14
相关论文
共 50 条
  • [11] Placental perfusion imaging using velocity-selective arterial spin labeling
    Zun, Zungho
    Limperopoulos, Catherine
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (03) : 1036 - 1047
  • [12] Comparative analysis of arterial spin labeling and dynamic susceptibility contrast perfusion imaging for quantitative perfusion measurements of brain tumors
    Jiang, Jingjing
    Zhao, Lingyun
    Zhang, Yan
    Zhang, Shun
    Yao, Yihao
    Qin, Yuanyuan
    Wang, Cong-Yi
    Zhu, Wenzhen
    INTERNATIONAL JOURNAL OF CLINICAL AND EXPERIMENTAL PATHOLOGY, 2014, 7 (06): : 2790 - 2799
  • [13] Quantitative non-contrast perfusion MRI in the body using arterial spin labeling
    Alvarez, Maria Guadalupe Mora
    Madhuranthakam, Ananth J.
    Udayakumar, Durga
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2024, 37 (04): : 681 - 695
  • [14] Quantitative analysis of arterial spin labeling FMRI data using a general linear model
    Hernandez-Garcia, Luis
    Jahanian, Hesamoddin
    Rowe, Daniel B.
    MAGNETIC RESONANCE IMAGING, 2010, 28 (07) : 919 - 927
  • [15] Brain perfusion magnetic resonance imaging using pseudocontinuous arterial spin labeling in 314 dogs and cats
    Hoffmann, Anne-Cecile
    Ruel, Yannick
    Gnirs, Kirsten
    Papageorgiou, Stella
    Zilberstein, Luca
    Nahmani, Sarah
    Boddaert, Nathalie
    Gaillot, Hugues
    JOURNAL OF VETERINARY INTERNAL MEDICINE, 2021, 35 (05) : 2327 - 2341
  • [16] Implementation of quantitative perfusion imaging techniques for functional brain mapping using pulsed arterial spin labeling
    Wong, EC
    Buxton, RB
    Frank, LR
    NMR IN BIOMEDICINE, 1997, 10 (4-5) : 237 - 249
  • [17] Implementation of Quantitative Perfusion Imaging Using Pulsed Arterial Spin Labeling at Ultra-High Field
    Gardener, A. G.
    Gowland, P. A.
    Francis, S. T.
    MAGNETIC RESONANCE IN MEDICINE, 2009, 61 (04) : 874 - 882
  • [18] Comparison of arterial spin labeling perfusion with dynamic susceptibility contrast perfusion in Moyamoya disease
    Yadav, Nishtha
    Pendharkar, Hima
    Gupta, Arun kumar
    Prasad, Chandrajit
    Shukla, Dhaval
    Kandavel, Thennarasu
    Bansal, Sonia
    JOURNAL OF NEUROSCIENCES IN RURAL PRACTICE, 2023, 14 (02) : 286 - 292
  • [19] Arterial spin labeling magnetic resonance perfusion imaging in cerebral ischemia
    Hartkamp, Nolan S.
    van Osch, Matthias J. P.
    Kappelle, Jaap
    Bokkers, Reinoud P. H.
    CURRENT OPINION IN NEUROLOGY, 2014, 27 (01) : 42 - 53
  • [20] Physiological Modulations in Arterial Spin Labeling Perfusion Magnetic Resonance Imaging
    Wu, Wen-Chau
    Edlow, Brian L.
    Elliot, Mark A.
    Wang, Jiongjiong
    Detre, John A.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2009, 28 (05) : 703 - 709