A graphical user interface for calculation of 3D dose distribution using Monte Carlo simulations

被引:10
作者
Chow, James C. L. [1 ]
Leung, Michael K. K. [1 ]
机构
[1] Univ Toronto & Radiat Med Program, Princess Margaret Hosp, Dept Radiat Oncol, Toronto, ON M5G 2M9, Canada
来源
INTERNATIONAL WORKSHOP ON MONTE CARLO TECHNIQUES IN RADIOTHERAPY DELIVERY AND VERIFICATION - THIRD MCGILL INTERNATIONAL WORKSHOP | 2008年 / 102卷
关键词
D O I
10.1088/1742-6596/102/1/012003
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
A software graphical user interface (GUI) for calculation of 3D dose distribution using Monte Carlo (MC) simulation is developed using MATLAB. This GUI (DOSCTP) provides a user-friendly platform for DICOM CT-based dose calculation using EGSnrcMP-based DOSXYZnrc code. It offers numerous features not found in DOSXYZnrc, such as the ability to use multiple beams from different phase-space files, and has built-in dose analysis and visualization tools. DOSCTP is written completely in MATLAB, with integrated access to DOSXYZnrc and CTCREATE. The program function may be divided into four subgroups, namely, beam placement, MC simulation with DOSXYZnrc, dose visualization, and export. Each is controlled by separate routines. The verification of DOSCTP was carried out by comparing plans with different beam arrangements (multi-beam/photon arc) on an inhomogeneous phantom as well as patient CT between the GUI and Pinnacle(3). DOSCTP was developed and verified with the following features: (1) a built-in voxel editor to modify CT-based DOSXYZnrc phantoms for research purposes; (2) multi-beam placement is possible, which cannot be achieved using the current DOSXYZnrc code; (3) the treatment plan, including the dose distributions, contours and image set can be exported to a commercial treatment planning system such as Pinnacle3 or to CERR using RTOG format for plan evaluation and comparison; (4) a built-in RTOG-compatible dose reviewer for dose visualization and analysis such as finding the volume of hot/cold spots in the 3D dose distributions based on a user threshold. DOSCTP greatly simplifies the use of DOSXYZnrc and CTCREATE, and offers numerous features that not found in the original user-code. Moreover, since phase-space beams can be defined and generated by the user, it is a particularly useful tool to carry out plans using specifically designed irradiators/accelerators that cannot be found in the Linac library of commercial treatment planning systems.
引用
收藏
页数:6
相关论文
共 8 条
  • [1] BRIESMEISTER JF, 1993, LA1265 LOS AL NAT LA
  • [2] COX LJ, 1997, UCRLJC126731 LAWR LI
  • [3] CERR: A computational environment for radiotherapy research
    Deasy, JO
    Blanco, AI
    Clark, VH
    [J]. MEDICAL PHYSICS, 2003, 30 (05) : 979 - 985
  • [4] Ma C. M., 1995, PIRS0509B NRC
  • [5] Clinical implementation of a Monte Carlo treatment planning system
    Ma, CM
    Mok, E
    Kapur, A
    Pawlicki, T
    Findley, D
    Brain, S
    Forster, K
    Boyer, AL
    [J]. MEDICAL PHYSICS, 1999, 26 (10) : 2133 - 2143
  • [6] Nelson W.R., 1985, Tech. Rep. SLAC-265
  • [7] BEAM - A MONTE-CARLO CODE TO SIMULATE RADIOTHERAPY TREATMENT UNITS
    ROGERS, DWO
    FADDEGON, BA
    DING, GX
    MA, CM
    WE, J
    MACKIE, TR
    [J]. MEDICAL PHYSICS, 1995, 22 (05) : 503 - 524
  • [8] ROGERS DWO, 2001, 509B NRC