Drift of Electrons and Performance of BF3 Filled Neutron Proportional Counters

被引:2
|
作者
Desai, Shraddha S. [1 ]
Rao, Mala N. [1 ]
机构
[1] Bhabha Atom Res Ctr, Solid State Phys Div, Bombay 400085, Maharashtra, India
来源
关键词
neutron scattering; neutron proportional counters; electron attachment coefficient; neutron detection efficiency;
D O I
10.1063/1.4980419
中图分类号
O469 [凝聚态物理学];
学科分类号
070205 ;
摘要
(BF3)-B-10 gas has regained interest among neutron detector developing laboratories as a promising alternative to globally scarce He-3. BF3 is an only direct replacement for use in proportional counter with coaxial geometry. Lower absorption cross section of B-10 and constraint on fill pressure limits the efficiency of these detectors. Electronegative nature of gas and impurities, affects the pulse shape at high fill gas pressure due to loss of electrons in drift region. Effect of electron attachment and position of primary charge cloud determines the gas gain and pulse broadening. Detailed study of gas behavior is essential to facilitate its efficient use in neutron detectors. Our in-house facility for generation-distillation of BF3 gas and development of neutron detectors has enabled us to carry out the detailed characterization of BF3 filled neutron detectors. Detectors are filled with the gas of best possible purity level by processing with repeated triple point distillations. Further detector is subjected to localized fine neutron beam tests. Position of neutron beam within the drift region is varied to investigate the pulse shape. Optimization of the detector design using these parameters, results in improvement of detection efficiency.
引用
收藏
页数:3
相关论文
共 50 条
  • [21] DETECTION EFFICIENCY OF BARE AND MODERATED BF3-GAS-FILLED PROPORTIONAL COUNTERS FOR ISOTROPIC NEUTRON FLUXES
    YAMASHITA, M
    STEPHENS, LD
    SMITH, AR
    PATTERSON, HW
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1966, 3 (08): : 343 - +
  • [22] DEEP UNDERGROUND NEUTRON-FLUX MEASUREMENT WITH LARGE BF3 COUNTERS
    BELLI, P
    BERNABEI, R
    DANGELO, S
    DEPASCALE, MP
    PAOLUZI, L
    SANTONICO, R
    TABORGNA, N
    IUCCI, N
    VILLORESI, G
    NUOVO CIMENTO DELLA SOCIETA ITALIANA DI FISICA A-NUCLEI PARTICLES AND FIELDS, 1989, 101 (06): : 959 - 966
  • [23] BF3 COUNTERS FOR USE IN FIELD INSTRUMENTATION
    PETERS, CW
    SNYDER, AL
    GALLIA, AS
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1966, NS13 (01) : 636 - &
  • [24] MEASUREMENT OF THE TIME JITTER IN BF3 COUNTERS
    SIMPSON, OD
    PHYSICAL REVIEW, 1954, 95 (02): : 600 - 600
  • [25] ON THE CONSTRUCTION AND LONG-TERM PERFORMANCE OF MEDIUM PRESSURE BF3 PROPORTIONAL COUNTERS USED FOR COSMIC-RAY RECORDING
    STOKER, PH
    NUCLEAR INSTRUMENTS & METHODS, 1960, 8 (01): : 23 - 26
  • [26] INVESTIGATIONS ABOUT THE CRITICAL RADIUS OF THE BF3 COUNTERS
    CSIKAI, J
    MOLNAR, E
    SCHLENK, B
    NUCLEAR INSTRUMENTS & METHODS, 1961, 10 (02): : 121 - 124
  • [27] DEVELOPMENT OF LONG-LIFE BF3 COUNTERS
    TOMODA, T
    FUKAKUSA, S
    YAMASHITA, S
    AKITA, K
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1985, 22 (02) : 120 - 128
  • [28] DEVELOPMENT OF LONG-LIFE BF3 COUNTERS
    TOMODA, T
    FUKAKUSA, S
    YAMASHITA, S
    AKITA, K
    TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1984, 46 : 767 - 768
  • [29] A Sensitive Neutron Counter with a High-Pressure Ionization Chamber Filled with BF3
    Zielczynski, Mieczyslaw
    Rusinowski, Zdzislaw
    Tulik, Piotr
    POLISH JOURNAL OF MEDICAL PHYSICS AND ENGINEERING, 2007, 13 (03): : 157 - 162
  • [30] CROSS SECTIONS FOR SCATTERING OF ELECTRONS ON BF3
    Radmilovic-Radjenovic, M.
    Varambhia, H. N.
    Vranic, M.
    Tennyson, J.
    Petrovic, Z. Lj.
    24TH SUMMER SCHOOL AND INTERNATIONAL SYMPOSIUM ON THE PHYSICS OF IONIZED GASES, CONTRIBUTED PAPERS, 2008, (84): : 57 - +