On the electrical safety of dielectric elastomer actuators in proximity to the human body

被引:44
作者
Pourazadi, S. [1 ]
Shagerdmootaab, A. [2 ]
Chan, H. [1 ]
Moallem, M. [2 ]
Menon, C. [1 ]
机构
[1] Simon Fraser Univ, MENRVA Res Grp, Sch Mechatron Syst & Engn Sci, Burnaby, BC, Canada
[2] Simon Fraser Univ, Sch Mechatron Syst Engn, Burnaby, BC, Canada
基金
加拿大健康研究院; 加拿大自然科学与工程研究理事会;
关键词
biosafety; dielectric elastomer actuators; smart materials; electric shock; high voltage; DEVICES; TRANSDUCERS; SILICONE; DRIVEN; DESIGN; MODEL;
D O I
10.1088/1361-665X/aa89b1
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
Novel devices based on the use of dielectric elastomer actuators (DEA) have been proposed for a large variety of different applications. In many of these applications, DEAs are envisioned to be in direct or close proximity to the human body. Since DEAs usually require high voltage for their actuation, the safety of individuals operating or using these devices should be ensured. In this paper, safety standards based on safe limits for electrical discharge are investigated. Flat and cylindrical DEA configurations, which are generally considered as the building blocks for the design of DEA-based systems, are investigated in detail. Relevant elements and factors that affect the electrical discharge of DEA devices are analyzed and guidelines to design DEA-based devices that are not of harm for humans are provided. The performed analyses are experimentally validated using flat DEA samples. The safety requirements that should be considered when wrapping DEAs around the body (specifically the legs) are also briefly investigated to provide a practical example of interest for the biomedical community.
引用
收藏
页数:14
相关论文
共 45 条
[1]   Fabrication and performance analysis of a DEA cuff designed for dry-suit applications [J].
Ahmadi, S. ;
Mattos, A. Camacho ;
Barbazza, A. ;
Soleimani, M. ;
Boscariol, P. ;
Menon, C. .
SMART MATERIALS AND STRUCTURES, 2013, 22 (03)
[2]  
Anderson I. A., 2009, P SOC PHOTO-OPT INS, V7287
[3]  
Bar-Cohen Y., 2004, ELECTROACTIVE POLYM
[4]  
Bell D.A., 2009, Fundamentals of Electric Circuits: Lab Manual
[5]   Dielectric elastomers as actuators for upper limb prosthetics: Challenges and opportunities [J].
Biddiss, Elaine ;
Chau, Tom .
MEDICAL ENGINEERING & PHYSICS, 2008, 30 (04) :403-418
[6]  
Cadick J, 2006, ELECT SAFETY HBD
[7]  
Carpi F, 2008, DIELECTRIC ELASTOMERS AS ELECTROMECHANICAL TRANSDUCERS: FUNDAMENTALS, MATERIALS, DEVICES, MODELS AND APPLICATIONS OF AN EMERGING ELECTROACTIVE POLYMER TECHNOLOGY, P1
[8]   Electromechanical characterisation of dielectric elastomer planar actuators: comparative evaluation of different electrode materials and different counterloads [J].
Carpi, F ;
Chiarelli, P ;
Mazzoldi, A ;
De Rossi, D .
SENSORS AND ACTUATORS A-PHYSICAL, 2003, 107 (01) :85-95
[9]   Enabling variable-stiffness hand rehabilitation orthoses with dielectric elastomer transducers [J].
Carpi, Federico ;
Frediani, Gabriele ;
Gerboni, Carlo ;
Gemignani, Jessica ;
De Rossi, Danilo .
MEDICAL ENGINEERING & PHYSICS, 2014, 36 (02) :205-211
[10]   Electroactive Elastomeric Actuator for All-Polymer Linear Peristaltic Pumps [J].
Carpi, Federico ;
Menon, Carlo ;
De Rossi, Danilo .
IEEE-ASME TRANSACTIONS ON MECHATRONICS, 2010, 15 (03) :460-470