Development of a flexible instrumented lumbar spine finite element model and comparison with in-vitro experiments

被引:6
作者
Leszczynski, Aleksander [1 ]
Meyer, Frank [1 ]
Charles, Yann-Philippe [2 ]
Deck, Caroline [1 ]
Willinger, Remy [1 ]
机构
[1] Univ Strasbourg, MMB Mech, ICube, Strasbourg, France
[2] Hop Univ Strasbourg, Serv Chirurg Rachis, Strasbourg, France
关键词
Finite element analysis; rod fracture; pseudarthrosis; instrumented FEM; lumbar spine; PEDICLE SUBTRACTION OSTEOTOMY; HUMAN NUCLEUS PULPOSUS; BIOMECHANICAL PROPERTIES; INTERVERTEBRAL DISCS; MECHANICAL-BEHAVIOR; CALIBRATION METHOD; DEFORMITY SURGERY; MOTION SEGMENT; RISK-FACTORS; MULTICENTER;
D O I
10.1080/10255842.2021.1948021
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Surgical corrections of degenerative lumbar scoliosis and sagittal malalignment are associated with significant complications, such as rod fractures and pseudarthrosis, particularly in the lumbosacral junction. Finite element studies can provide relevant insights to improve performance of spinal implants. The aim of the present study was to present the development of non-instrumented and instrumented Finite Element Models (FEMs) of the lumbopelvic spine and to compare numerical results with experimental data available in the literature. The lumbo-pelvic spine FEM was based on a CT-scan from an asymptomatic volunteer representing the 50th percentile male. In a first step a calibration of mechanical properties was performed in order to obtain a quantitative agreement between numerical results and experimental data for defect stages of spinal segments. Then, FEM results were compared in terms of range of motion and strains in rods to in-vitro experimental data from the literature for flexible non-instrumented and instrumented lumbar spines. Numerical results from the calibration process were consistent with experimental data, especially in flexion. A positive agreement was obtained between FEM and experimental results for the lumbar and sacroiliac segments. Instrumented FEMs predicted the same trends as experimental in-vitro studies. The instrumentation configuration consisting of double rods and an interbody cage at L5-S1 maximally reduced range of motion and strains in main rods and thus had the lowest risk of pseudarthrosis and rod fracture. The developed FEMs were found to be consistent with published experimental results; therefore they can be used for further post-operative complication investigations.
引用
收藏
页码:221 / 237
页数:17
相关论文
共 62 条
  • [1] Altman D. G., 1999, Practical Statistics for Medical Research
  • [2] Supplementary delta-rod configurations provide superior stiffness and reduced rod stress compared to traditional multiple-rod configurations after pedicle subtraction osteotomy: a finite element study
    Berjano, Pedro
    Xu, Ming
    Damilano, Marco
    Scholl, Thomas
    Lamartina, Claudio
    Jekir, Michael
    Galbusera, Fabio
    [J]. EUROPEAN SPINE JOURNAL, 2019, 28 (09) : 2198 - 2207
  • [3] Does Treatment (Nonoperative and Operative) Improve the Two-Year Quality of Life in Patients With Adult Symptomatic Lumbar Scoliosis A Prospective Multicenter Evidence-Based Medicine Study
    Bridwell, Keith H.
    Glassman, Steven
    Horton, William
    Shaffrey, Christopher
    Schwab, Frank
    Zebala, Lukas P.
    Lenke, Lawrence G.
    Hilton, Joan F.
    Shainline, Michael
    Baldus, Christine
    Wootten, David
    [J]. SPINE, 2009, 34 (20) : 2171 - 2178
  • [4] Automated finite element meshing of the lumbar spine: Verification and validation with 18 specimen-specific models
    Campbell, J. Q.
    Coombs, D. J.
    Rao, M.
    Rullkoetter, P. J.
    Petrella, A. J.
    [J]. JOURNAL OF BIOMECHANICS, 2016, 49 (13) : 2669 - 2676
  • [5] Influence of an auxiliary facet system on intervertebral discs and adjacent facet joints
    Charles, Yann Philippe
    Lima, Lucas Venancio Pires Carvalho
    Persohn, Sylvain
    Rouch, Philippe
    Steib, Jean-Paul
    Skalli, Wafa
    [J]. SPINE JOURNAL, 2013, 13 (10) : 1293 - 1300
  • [6] Instability and instrumentation failures after a PSO: a finite element analysis
    Charosky, Sebastien
    Moreno, Pierre
    Maxy, Philippe
    [J]. EUROPEAN SPINE JOURNAL, 2014, 23 (11) : 2340 - 2349
  • [7] BIOMECHANICAL PROPERTIES OF SPINAL LIGAMENTS AND A HISTOLOGICAL STUDY OF THE SUPRASPINAL LIGAMENT IN TRACTION
    CHAZAL, J
    TANGUY, A
    BOURGES, M
    GAUREL, G
    ESCANDE, G
    GUILLOT, M
    VANNEUVILLE, G
    [J]. JOURNAL OF BIOMECHANICS, 1985, 18 (03) : 167 - 176
  • [8] Biomechanical comparison between lumbar disc arthroplasty and fusion
    Chen, Shih-Hao
    Zhong, Zheng-Cheng
    Chen, Chen-Sheng
    Chen, Wen-Jer
    Hung, Chinghua
    [J]. MEDICAL ENGINEERING & PHYSICS, 2009, 31 (02) : 244 - 253
  • [9] Material properties in unconfined compression of human nucleus pulposus, injectable hyaluronic acid-based hydrogels and tissue engineering scaffolds
    Cloyd, Jordan M.
    Malhotra, Neil R.
    Weng, Lihui
    Chen, Weiliam
    Mauck, Robert L.
    Elliott, Dawn M.
    [J]. EUROPEAN SPINE JOURNAL, 2007, 16 (11) : 1892 - 1898
  • [10] Construct Rigidity after Fatigue Loading in Pedicle Subtraction Osteotomy with or without Adjacent Interbody Structural Cages
    Deviren, Vedat
    Tang, Jessica A.
    Scheer, Justin K.
    Buckley, Jenni M.
    Pekmezci, Murat
    McClellan, R. Trigg
    Ames, Christopher P.
    [J]. GLOBAL SPINE JOURNAL, 2012, 2 (04) : 213 - 220