Calculating equivalent dose received from a patient undergoing nuclear medicine procedure by merge phantoms tool and GAMOS/Geant4 6.0.0 software

被引:4
作者
Nguyen Thi Phuong Thao [1 ,2 ]
Nguyen Thien Trung [3 ]
Nguyen Dong Son [4 ]
机构
[1] Vietnam Atom Energy Inst, 59 Ly Thuong Kiet, Hanoi, Vietnam
[2] Nguyen Huu Huan High Sch, 1 Doan Ket, Ho Chi Minh City, Vietnam
[3] TechBase, 67 Le Loi,Distr 1, Ho Chi Minh City, Vietnam
[4] VNUHCM Univ Sci, 227 Nguyen Van Cu,Dist 5, Ho Chi Minh City, Vietnam
来源
PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS | 2019年 / 68卷
关键词
DICOM; Phantom merging; GAMOS; GEANT4; Equivalent dose; Nuclear medicine;
D O I
10.1016/j.ejmp.2019.11.004
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: This report introduces a tool for merging two voxel phantoms to calculate the deposited dose that a person receives from a patient undergoing Nuclear medicine procedures. Materials and methods: The phantoms must be converted to the text format used by GEANT4 to treat DICOM images via the GAMOS utilities. The Merge Phantoms Tool can merge two phantoms in two different cases: standing either side by side or opposite. The merged phantom is also in text format and is subsequently input back into GAMOS to calculate the equivalent dose that a person receives from a patient. The equivalent doses to the eyes of people in contact are calculated in a case where a patient was administered 185 MBq of 18F-FDG during a PET examination. Results: The corresponding doses when the two phantoms are standing opposite are greater than those when they are standing side by side and smaller than those from point and tube source calculated by Sumi Yokoyama at any distance. Conclusions: The Merge phantoms tool and GAMOS software can be used to calculate the deposited dose that a person receives from a patient. An accurate dose calculation can be used for radiation protection, or deciding whether a patient can be released from isolation if the dose is small even in a close contact.
引用
收藏
页码:41 / 46
页数:6
相关论文
共 16 条
[1]  
[Anonymous], 2014, PROG NUCL SCI TECHNO
[2]  
[Anonymous], 2008, IEEE P NUC SCI S
[3]   CPU time optimization and precise adjustment of the Geant4 physics parameters for a VARIAN 2100 C/D gamma radiotherapy linear accelerator simulation using GAMOS [J].
Arce, Pedro ;
Ignacio Lagares, Juan .
PHYSICS IN MEDICINE AND BIOLOGY, 2018, 63 (03)
[4]   GAMOS: A framework to do GEANT4 simulations in different physics fields with an user-friendly interface [J].
Arce, Pedro ;
Ignacio Lagares, Juan ;
Harkness, Laura ;
Perez-Astudillo, Daniel ;
Canadas, Mario ;
Rato, Pedro ;
de Prado, Maria ;
Abreu, Yamiel ;
de Lorenzo, Gianluca ;
Kolstein, Machiel ;
Diaz, Angelina .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 735 :304-313
[5]   Cataract Risk in a Cohort of US Radiologic Technologists Performing Nuclear Medicine Procedures [J].
Bernier, Marie-Odile ;
Journy, Neige ;
Villoing, Daphnee ;
Doody, Michele M. ;
Alexander, Bruce H. ;
Linet, Martha S. ;
Kitahara, Cari M. .
RADIOLOGY, 2018, 286 (02) :592-601
[6]  
de Klerk JMH, 2000, J NUCL MED, V41, P1876
[7]  
European Commission, 1998, RAD PROT 97 RAD PROT
[8]   Medical Image File Formats [J].
Larobina, Michele ;
Murino, Loredana .
JOURNAL OF DIGITAL IMAGING, 2014, 27 (02) :200-206
[9]   Estimation of the release time from isolation for patients with differentiated thyroid cancer treated with high-dose I-131 [J].
Lee J.H. ;
Park S.G. .
Nuclear Medicine and Molecular Imaging, 2010, 44 (4) :241-245
[10]   Radiation dose produced by patients during radiopharmaceutical incorporation in nuclear medicine diagnostic procedures [J].
Moran, V. ;
Prieto, E. ;
Garcia-Garcia, B. ;
Barbes, B. ;
Ribelles, M. J. ;
Richter, J. A. ;
Marti-Climent, J. M. .
REVISTA ESPANOLA DE MEDICINA NUCLEAR E IMAGEN MOLECULAR, 2016, 35 (03) :175-185