Comparative study of the accuracy of CBCT implant site measurements using different software programs

被引:12
作者
Al-Ekrish, Asma'a A. [1 ]
机构
[1] King Saud Univ, Dept Oral Med & Diagnost Sci, Coll Dent, Div Oral & Maxillofacial Radiol, POB 60169, Riyadh 11545, Saudi Arabia
关键词
Diagnostic Imaging; Dimensional measurement accuracy; Cone beam computed tomography; Dental implants; Software Validation; CBCT; BEAM COMPUTED-TOMOGRAPHY; CONE-BEAM; LINEAR MEASUREMENTS; RELIABILITY; IMAGES; SCANS; CT;
D O I
10.1016/j.sdentj.2020.07.003
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: To measure and compare the accuracy of the linear dimensions of implant sites recorded from cone beam computed tomography (CBCT) images using Blue Sky Plan, coDiagnostiX, and RadiAnt. Materials and Methods: Five human dry skulls were imaged with a CBCT device then sectioned to obtain sample transverse cross-sections of the edentulous ridges, and the height and width of the ridge were measured with a digital caliper to provide the gold standard measurements. The CBCT datasets were exported in DICOM format and imported into the three test software programs which were used to obtain reformatted sectional images corresponding to the sample transverse cross-sections, and the height and width of the edentulous ridge was recorded using the linear measurement tool. Reliability of the measurements were measured using the intraclass correlation coefficient. One-sample t-test (test value: zero) was used to test the statistical significance of the mean of the absolute errors for each software program. Analysis of Variance with Repeated Measures was used to test the statistical significance of the difference between the means of the absolute errors obtained by the different software programs. Statistical significance was set at a p-value of 0.05. Results: The reliability of the gold standard and image measurements were excellent. All three software programs demonstrated a statistically significant mean absolute measurement error of between 0.43 and 0.56 mm (p-value < 0.01), but no significant difference in error values was found between any of the tested programs (p-value = 0.18). Conclusions: There was no statistically significant difference in accuracy of linear CBCT measurements of implant sites recorded using Blue Sky Plan, coDiagnostiX, and RadiAnt. (C) 2021 The Authors. Production and hosting by Elsevier B.V. on behalf of King Saud University.
引用
收藏
页码:355 / 361
页数:7
相关论文
共 26 条
[1]   A comparative study of the accuracy and reliability of multidetector computed tomography and cone beam computed tomography in the assessment of dental implant site dimensions [J].
Al-Ekrish, A. A. ;
Ekram, M. .
DENTOMAXILLOFACIAL RADIOLOGY, 2011, 40 (02) :67-75
[2]   Radiology of Implant Dentistry [J].
Al-Ekrish, Asma'a Abdurrahman .
RADIOLOGIC CLINICS OF NORTH AMERICA, 2018, 56 (01) :141-+
[3]   Effect of exposure time on the accuracy and reliability of cone beam computed tomography in the assessment of dental implant site dimensions in dry skulls [J].
Al-Ekrish, Asmaa A. .
SAUDI DENTAL JOURNAL, 2012, 24 (3-4) :127-134
[4]   The intrinsic error of a stereolithographic surgical template in implant guided surgery [J].
Cassetta, M. ;
Di Mambro, A. ;
Giansanti, M. ;
Stefanelli, L. V. ;
Cavallini, C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2013, 42 (02) :264-275
[5]  
Dell Ralph B, 2002, ILAR J, V43, P207
[6]   Accuracy of linear measurements on CBCT images related to presurgical implant treatment planning: A systematic review [J].
Fokas, George ;
Vaughn, Vida M. ;
Scarfe, William C. ;
Bornstein, Michael M. .
CLINICAL ORAL IMPLANTS RESEARCH, 2018, 29 :393-415
[7]   Evaluation of the accuracy of linear measurements on multi slice and cone beam computed tomography scans to detect the mandibular canal during bilateral sagittal split osteotomy of the mandible [J].
Freire-Maia, B. ;
Machado, V. deC. ;
Valerio, C. S. ;
Custodio, A. L. N. ;
Manzi, F. R. ;
Junqueira, J. L. C. .
INTERNATIONAL JOURNAL OF ORAL AND MAXILLOFACIAL SURGERY, 2017, 46 (03) :296-302
[8]   The accuracy of linear measurements of maxillary and mandibular edentulous sites in cone-beam computed tomography images with different fields of view and voxel sizes under simulated clinical conditions [J].
Ganguly, Rumpa ;
Ramesh, Aruna ;
Pagni, Sarah .
IMAGING SCIENCE IN DENTISTRY, 2016, 46 (02) :93-101
[9]   Accuracy of Linear Measurements in Cone Beam Computed Tomography With Different Voxel Sizes [J].
Gomes Torres, Marianna Guanaes ;
Flores Campos, Paulo Sergio ;
Neto Segundo, Nilson Pena ;
Navarro, Marcus ;
Crusoe-Rebello, Ieda .
IMPLANT DENTISTRY, 2012, 21 (02) :150-155
[10]   Linear Measurement Accuracy of Dental CT Images Obtained by 64-Slice Multidetector Row CT: The Effects of Mandibular Positioning and Pitch Factor at CT Scanning [J].
Kamiyama, Yosuke ;
Nakamura, Shin ;
Abe, Tatsuhiko ;
Munakata, Motohiro ;
Nomura, Yoshikazu ;
Watanabe, Hiroshi ;
Akiyama, Masako ;
Kurabayashi, Toru .
IMPLANT DENTISTRY, 2012, 21 (06) :496-501