Transvenous extraction profile of Riata leads: Procedural outcomes and technical complexity of mechanical removal

被引:25
作者
Bongiorni, Maria Grazia [1 ]
Di Cori, Andrea [1 ]
Segreti, Luca [1 ]
Zucchelli, Giulio [1 ]
Viani, Stefano [1 ]
Paperini, Luca [1 ]
De Lucia, Raffaele [1 ]
Levorato, Dianora [1 ]
Boem, Adriano [1 ]
Soldati, Ezio [1 ]
机构
[1] Univ Hosp Pisa, Cardiothorac & Vasc Dept, Cardiol Div 2, I-56124 Pisa, Italy
关键词
Riata; Sprint Fidelis; Lead extraction; Jugular vein; Mechanical dilation; CARDIOVERTER-DEFIBRILLATOR LEAD; SINGLE-CENTER EXPERIENCE; SPRINT FIDELIS; ICD LEADS; FAILURE; PREVALENCE; PREDICTORS; DILATATION; FAMILY;
D O I
10.1016/j.hrthm.2014.12.013
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND Riata (RT) and Sprint Fidelis (SF) leads were recalled by the United States Food and Drug Administration because of an increased rate of failure mainly due to conductor fracture or insulation abrasion. According to lead design and type of failure, extraction complexity may be different, potentially affecting procedural outcomes and indications. OBJECTIVE The purpose of this study was to assess the extraction profile of RT leads with and without cable externalization in comparison to SF leads. METHODS From January 1997 to April 2014, all consecutive RT and SF leads extracted transvenously were analyzed. Among 661 consecutive patients with 705 ventricular implantable cardioverter-defibrillator (ICD) leads extracted, 194 patients with 134 RT leads (RT group) and 61 SF leads (SF group) were identified. Removal indications often were infective (64%), and extracted leads had a prevalence of dual-coil design (89%). Baseline patients and lead characteristics were comparable between groups. RESULTS Success rate was high in both groups (97.8% RT vs 100% SF) without major complications. Mechanical dilation was comparable between groups, but RT leads often required larger sheaths (11.7 +/- 1.4 vs 11.3 +/- 1.4), a more frequent crossover to the internal transjugular approach (14% vs 3%), and a longer procedural time (23 +/- 33 minutes vs 12 +/- 16 minutes). Implantation time (odds ratio 4.84, 95% confidence interval 1.05-22.2, P = .042) and RT leads (odds ratio 1.04, 95% confidence interval 1.02-1.06, P < .001) were independent predictors of the internal transjugular approach. CONCLUSION Extraction of RT leads is feasible and effective. However, extraction of RT leads is more complex than that of SF leads. Lack of coil backfilling and cable externalization in RT group may account for these differences.
引用
收藏
页码:580 / 587
页数:8
相关论文
共 35 条
  • [1] ANDERSON JM, 1993, CARDIOVASC PATHOL, V2, pS33
  • [2] [Anonymous], 2011, VOL PHYS ADV LETT RI, P28
  • [3] Management of malfunctioning and recalled pacemaker and defibrillator leads: results of the European Heart Rhythm Association survey
    Bongiorni, Maria Grazia
    Dagres, Nikolaos
    Estner, Heidi
    Pison, Laurent
    Todd, Derick
    Blomstrom-Lundqvist, Carina
    [J]. EUROPACE, 2014, 16 (11): : 1674 - 1678
  • [4] Transvenous removal of pacing and implantable cardiac defibrillating leads using single sheath mechanical dilatation and multiple venous approaches: high success rate and safety in more than 2000 leads
    Bongiorni, Maria Grazia
    Soldati, Ezio
    Zucchelli, Giulio
    Di Cori, Andrea
    Segreti, Luca
    De Lucia, Raffaele
    Solarino, Gianluca
    Balbarini, Alberto
    Marzilli, Mario
    Mariani, Mario
    [J]. EUROPEAN HEART JOURNAL, 2008, 29 (23) : 2886 - 2893
  • [5] Bongiorni MG, 2011, TRANSVENOUS LEAD EXTRACTION: FROM SIMPLE TRACTION TO INTERNAL TRANSJUGLAR APPROACH, P1, DOI 10.1007/978-88-470-1466-4
  • [6] Transvenous extraction of implantable cardioverter-defibrillator leads under advisory-A comparison of Riata, Sprint Fidelis, and non-recalled implantable cardioverter-defibrillator leads
    Brunner, Michael P.
    Cronin, Edmond M.
    Jacob, Jessen
    Duarte, Valeria E.
    Tarakji, Khaldoun G.
    Martin, David O.
    Callahan, Thomas
    Borek, P. Peter
    Cantillon, Daniel J.
    Niebauer, Mark J.
    Saliba, Walid I.
    Kanj, Mohamed
    Wazni, Oussama
    Baranowski, Bryan
    Wilkoff, Bruce L.
    [J]. HEART RHYTHM, 2013, 10 (10) : 1444 - 1450
  • [7] Chester KM, 2010, IMPORTANT PRODUCT IN
  • [8] Pathways for training and accreditation for transvenous lead extraction: a European Heart Rhythm Association position paper
    Deharo, J. C.
    Bongiorni, M. G.
    Rozkovec, A.
    Bracke, F.
    Defaye, P.
    Fernandez-Lozano, I.
    Golzio, P. G.
    Hansky, B.
    Kennergren, C.
    Manolis, A. S.
    Mitkowski, P.
    Platou, E. S.
    Love, C.
    Wilkoff, B.
    [J]. EUROPACE, 2012, 14 (01): : 124 - 134
  • [9] Large, Single-Center Experience in Transvenous Coronary Sinus Lead Extraction: Procedural Outcomes and Predictors for Mechanical Dilatation
    Di Cori, Andrea
    Bongiorni, Maria Grazia
    Zucchelli, Giulio
    Segreti, Luca
    Viani, Stefano
    De Lucia, Raffaele
    Paperini, Luca
    Soldati, Ezio
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2012, 35 (02): : 215 - 222
  • [10] Transvenous Extraction Performance of Expanded Polytetrafluoroethylene Covered ICD Leads in Comparison to Traditional ICD Leads in Humans
    Di Cori, Andrea
    Bongiorni, Maria Grazia
    Zucchelli, Giulio
    Segreti, Luca
    Viani, Stefano
    Paperini, Luca
    Soldati, Ezio
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2010, 33 (11): : 1376 - 1381