Use of single particle counters for the determination of the number and size distribution of colloids in natural surface waters

被引:39
|
作者
Rossé, P
Loizeau, JL
机构
[1] Univ Geneva, Inst FA Forel, CH-1290 Versoix, Switzerland
[2] Univ Geneva, Ctr Etud Sci Nat & Environm, CH-1290 Versoix, Switzerland
关键词
single particle counter; calibration; colloid concentration; particle size distribution; natural surface water;
D O I
10.1016/S0927-7757(02)00565-4
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
Particle size distribution (PSD) is a fundamental physical property, which should be measured to understand the role of the colloids in the biogeochemical cycle of aquatic contaminants. The single particle counter (SPC) is an instrument designed to precisely determine sub-micron PSD. The advantages of this system are: to give an absolute colloid number concentration, to measure without bias highly polydispersed samples, to avoid artefacts resulting from sample preconcentration, to be transportable, allowing on-site measurements. This study presents the results of the methodological work done on our SPC, a 2-counter (one monitor and spectrometer) based system including a precision pump for sample injection and dilution. This system is able to count and size colloids from 50 nm to 2 mum into 19 size classes. Calibration work was performed with standard latex beads and natural samples from various surface waters. The quantification limit on the colloid number concentration for the smallest (50-100 nm), the medium (400-500 nm) and the largest ( > 2 mum) size classes are 1.0 x 10(4), 1.1 x 10(2) and 18 ml(-1), respectively. Instrument saturation occurs at 8 x 10(8) ml(-1) for the 50-100 size class, and at 2 x 10(3) ml(-1) for medium and highest size classes. The relative repeatability varies between 7 and 29% for the different size classes in a synthetic, polydispersed sample reproducing typical environmental colloid concentration. These values are not significantly different from the with-in replicates variability. The verification of the factory calibration shows that measured concentrations are between 27 and 106% of the nominal concentration of standards. In conclusion, the presented SPC system gives reliable results of colloid number concentration and size distribution in a wide range of natural surface waters and offers new opportunities for on-site studies. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:109 / 120
页数:12
相关论文
共 50 条
  • [41] Application of Single-Particle ICP-MS to Determine the Mass Distribution and Number Concentrations of Environmental Nanoparticles and Colloids
    Mansor, Muammar
    Drabesch, Soeren
    Bayer, Timm
    Van Le, Anh
    Chauhan, Ankita
    Schmidtmann, Johanna
    Peiffer, Stefan
    Kappler, Andreas
    ENVIRONMENTAL SCIENCE & TECHNOLOGY LETTERS, 2021, 8 (07): : 589 - 595
  • [42] Determination of particle size distribution by FMR measurements
    Folly, WSD
    de Biasi, RS
    BRAZILIAN JOURNAL OF PHYSICS, 2001, 31 (03) : 398 - 401
  • [43] PARTICLE-SIZE DISTRIBUTION DETERMINATION BY TURBIDIMETRY
    GLEDHILL, RJ
    JOURNAL OF PHYSICAL CHEMISTRY, 1962, 66 (03): : 458 - &
  • [44] MICROWAVE DETERMINATION OF PARTICLE-SIZE DISTRIBUTION
    BARTNOFF, S
    ATLAS, D
    JOURNAL OF METEOROLOGY, 1951, 8 (02): : 130 - 131
  • [45] AGRICULTURAL DUSTS - DETERMINATION OF PARTICLE SIZE DISTRIBUTION
    GULLSTROM, DK
    BURCHFIELD, HP
    ANALYTICAL CHEMISTRY, 1948, 20 (12) : 1174 - 1177
  • [46] Determination of particle size distribution of titanium dioxide
    Balcárek, J
    Goebel, A
    Smejkal, Z
    Dubánek, L
    CHEMICKE LISTY, 1998, 92 (11): : 912 - 916
  • [47] DETERMINATION, PRESENTATION AND EVALUATION OF PARTICLE SIZE DISTRIBUTION
    KOGEL, J
    HORSCH, W
    PHARMAZIE, 1972, 27 (11): : 722 - &
  • [48] The ultra-centrifuge, a new instrument for the determinition of size and distribution of size of particle in amicroscopic colloids
    Svedberg, T
    Rinde, H
    JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 1924, 46 : 2677 - 2693
  • [49] IMPROVEMENTS IN THE USE OF PARTICLE COUNTERS FOR THE MEASUREMENTS OF NATURAL PARTICLES IN SEA WATER.
    Read, Peter
    Fladby, Tron H.
    Brekke, Tormod
    Society of Petroleum Engineers of AIME, (Paper) SPE, 1985,
  • [50] Effect of the filter feeder Daphnia on the particle size distribution of inorganic colloids in freshwaters
    Filella, Montserrat
    Rellstab, Christian
    Chanudet, Vincent
    Spaak, Piet
    WATER RESEARCH, 2008, 42 (8-9) : 1919 - 1924