Ultrahigh sensitivity in liquid-crystal-based immunodetection by surface modification of the alignment layer

被引:1
作者
Lee, Mon-Juan [1 ]
Su, Hui-Wen [1 ]
Sun, Shih-Hung [1 ]
Lee, Wei [1 ]
机构
[1] Chang Jung Christian Univ, Dept Biosci Technol, Tainan 71101, Taiwan
来源
LIQUID CRYSTALS XVIII | 2014年 / 9182卷
关键词
Liquid crystals; alignment layers; surface modification; biosensors; immunodetection; cancer biomarker; LABEL-FREE; BIOSENSORS;
D O I
10.1117/12.2057362
中图分类号
O7 [晶体学];
学科分类号
0702 ; 070205 ; 0703 ; 080501 ;
摘要
Liquid crystals (LCs) can be employed in biological sensing and applied to label-free immunodetection owing to their unique birefringent, anchoring, alignment and collective properties. Like all different kinds of immunoassays, both sensitivity and specificity are universally the most important key points of concern. In this study, we developed various approaches toward ultrahigh sensitivity in LC-based immunoassays for potential clinical applications. The LC-based immunodetection technique was demonstrated with the cancer biomarker CA125, which is a mucin-like glycoprotein commonly present in the serum of patients with ovarian and other types of cancer. By using LCs with larger birefringence, such as HDN, the sensitivity of immunodetection was drastically enhanced compared to 5CB, which has a relatively lower birefringence and is commonly used in LC biosensing studies. In addition, UV modification of the monolayer of dimethyloctadecyl[3-(trimethoxysilyl) propyl] ammonium chloride (DMOAP), which functions as the alignment layer for LCs, is suggested to increase functional groups suitable for covalent binding of biomolecules, stabilizing the immobilized anti-CA125 antibody and the immunocomplex thus formed, and contributing to the lowered detection limit. Finally, we show that it is possible to directly identify the formation of CA125 immunocomplex with HDN in a mixture of antigen and antibody without the need to eliminate unbound or unreacted biomolecules through washing, thereby creating a simplified procedure for faster LC-based immunoassay. It is evident from our results that label-free immunodetection based on birefringent LCs represents a novel biosensing technique with potentials to detect a wide range of biomolecules, providing an alternative to conventional label-based immunoassays.
引用
收藏
页数:7
相关论文
共 14 条
  • [1] REACTIVITY OF A MONOCLONAL-ANTIBODY WITH HUMAN OVARIAN-CARCINOMA
    BAST, RC
    FEENEY, M
    LAZARUS, H
    NADLER, LM
    COLVIN, RB
    KNAPP, RC
    [J]. JOURNAL OF CLINICAL INVESTIGATION, 1981, 68 (05) : 1331 - 1337
  • [2] Liquid crystal-based immunoassays for detecting hepatitis B antibody
    Chen, Chih-Hsin
    Yang, Kun-Lin
    [J]. ANALYTICAL BIOCHEMISTRY, 2012, 421 (01) : 321 - 323
  • [3] Detection and Quantification of DNA Adsorbed on Solid Surfaces by Using Liquid Crystals
    Chen, Chih-Hsin
    Yang, Kun-Lin
    [J]. LANGMUIR, 2010, 26 (03) : 1427 - 1430
  • [4] Orientations of nentatic liquid crystals on surfaces presenting controlled densities of peptides: Amplification of protein-peptide binding events
    Clare, BH
    Abbott, NL
    [J]. LANGMUIR, 2005, 21 (14) : 6451 - 6461
  • [5] Bio-recognition and detection using liquid crystals
    Hussain, A.
    Pina, A. S.
    Roque, A. C. A.
    [J]. BIOSENSORS & BIOELECTRONICS, 2009, 25 (01) : 1 - 8
  • [6] Kim SR, 2001, ADV MATER, V13, P1445, DOI 10.1002/1521-4095(200110)13:19<1445::AID-ADMA1445>3.0.CO
  • [7] 2-9
  • [8] DNA hybridization-induced reorientation of liquid crystal anchoring at the nematic liquid crystal/aqueous interface
    Price, Andrew D.
    Schwartz, Daniel K.
    [J]. JOURNAL OF THE AMERICAN CHEMICAL SOCIETY, 2008, 130 (26) : 8188 - 8194
  • [9] Su H. W., 2014, J BIOMED OP IN PRESS
  • [10] Signal-Enhanced Liquid-Crystal DNA Biosensors Based on Enzymatic Metal Deposition
    Tan, Hui
    Yang, Shengyuan
    Shen, Guoli
    Yu, Ruqin
    Wu, Zhaoyang
    [J]. ANGEWANDTE CHEMIE-INTERNATIONAL EDITION, 2010, 49 (46) : 8608 - 8611