Hyper-branch sensing polymer batch self-assembled on resonant micro-cantilevers with a coupling-reaction route

被引:16
作者
Guo, Shuanbao [1 ]
Xu, Pengcheng [1 ]
Yu, Haitao [1 ]
Li, Xinxin [1 ]
Cheng, Zhenxing [1 ]
机构
[1] Chinese Acad Sci, Shanghai Inst Microsyst & Informat Technol, State Key Lab Transducer Technol, Shanghai 200050, Peoples R China
关键词
Coupling reaction; Resonant cantilever; Hyper branched polymer; Self assembly; Batch fabrication; Gas sensor; REDUCED GRAPHENE OXIDE; BOND ACIDIC POLYMERS; CHEMICAL SENSORS; MESOPOROUS SILICA; ARRAY SENSORS; MICROCANTILEVER; NANOPARTICLES; VAPOR; GOLD;
D O I
10.1016/j.snb.2014.12.077
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to develop a volume fabrication route for chemical sensors, hydrogen-bond acidic hyper-branched polymer is synthesized and directly self-assembled in-batch onto MEMS resonant micro-cantilevers as sensing layer. The batch self-assembly is via a facile coupling reaction between the -SH group in the self-assembled monolayer (SAM) and one -OH group in the hyper-branched polymer. During the self-assembly process of the hyper-branched polymer, the polyurethane-industry used isophorone diisocyanate (IPDI) is employed as the key coupling reagent, since the two -N=C=O coupling groups in IPDI feature different reactivity. The -N=C=O group with higher reactivity is firstly reacted with the -SH group pre-grown at the cantilever surface. Then, another -N=C=O group with lower reactivity reacts with one -OH group in the hyper-branched polymer. In this way the hydrogen-bond acidic hyper-branch polymer can be batch grafted onto a run of micro-cantilevers for uniform sensing to targeted gas. Through this route, the resonant cantilever gas sensors can be batch produced for uniform detection of trace organophosphates (OPs). Based on the specific interaction between the -OH sensing group and the P=O group in OP, the targeted molecules can be captured by the hyper-branched sensing polymer, and the mass addition induced frequency shift of the resonant cantilever is output as sensing signal. Sensing experiment is implemented for the sensors taken from one fabrication batch, resulting in satisfactory consistency in sensing performance. Taking 5 sensors as example, the deviation of the sensing response to 2 ppm dimethyl methylphosphonate (DMMP) is less than 1%. Besides, the sensor shows good repeatability/selectivity and good linear response to various concentrations (300 ppb to 1.5 ppm) of DMMP. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:943 / 950
页数:8
相关论文
共 41 条
[1]  
Atkins P., 2007, ATKINS PHYS CHEM, P987
[2]   Rapid functionalization of cantilever array sensors by inkjet printing [J].
Bietsch, A ;
Zhang, JY ;
Hegner, M ;
Lang, HP ;
Gerber, C .
NANOTECHNOLOGY, 2004, 15 (08) :873-880
[3]   Inkjet deposition of alkanethiolate monolayers and DNA oligonucleotides on gold: Evaluation of spot uniformity by wet etching [J].
Bietsch, A ;
Hegner, M ;
Lang, HP ;
Gerber, C .
LANGMUIR, 2004, 20 (12) :5119-5122
[4]   2,4,6-Trinitrotoluene (TNT) Chemical Sensing Based on Aligned Single-Walled Carbon Nanotubes and ZnO Nanowires [J].
Chen, Po-Chiang ;
Sukcharoenchoke, Saowalak ;
Ryu, Koungmin ;
de Arco, Lewis Gomez ;
Badmaev, Alexander ;
Wang, Chuan ;
Zhou, Chongwu .
ADVANCED MATERIALS, 2010, 22 (17) :1900-+
[5]   Use of the longitudinal mode of screen-printed piezoelectric cantilevers coated with PEUT for toluene detection: Comparison with silicon cantilevers [J].
Debeda, H. ;
Lakhmi, R. ;
Lucat, C. ;
Dufour, I. .
SENSORS AND ACTUATORS B-CHEMICAL, 2013, 187 :198-203
[6]   Synthesis and evaluation of a new polysiloxane as SAW sensor coatings for DMMP detection [J].
Du, Xiaosong ;
Ying, Zhihua ;
Jiang, Yadong ;
Liu, Zhongxiang ;
Yang, Taojun ;
Xie, Guangzhong .
SENSORS AND ACTUATORS B-CHEMICAL, 2008, 134 (02) :409-413
[7]   Translating biomolecular recognition into nanomechanics [J].
Fritz, J ;
Baller, MK ;
Lang, HP ;
Rothuizen, H ;
Vettiger, P ;
Meyer, E ;
Güntherodt, HJ ;
Gerber, C ;
Gimzewski, JK .
SCIENCE, 2000, 288 (5464) :316-318
[8]   Microcantilevers: Sensing chemical interactions via mechanical motion [J].
Goeders, Karen M. ;
Colton, Jonathan S. ;
Bottomley, Lawrence A. .
CHEMICAL REVIEWS, 2008, 108 (02) :522-542
[9]   Hydrogen-bond acidic polymers for chemical vapor sensing [J].
Grate, Jay W. .
CHEMICAL REVIEWS, 2008, 108 (02) :726-745
[10]   ROLE OF SELECTIVE SORPTION IN CHEMIRESISTOR SENSORS FOR ORGANOPHOSPHORUS DETECTION [J].
GRATE, JW ;
KLUSTY, M ;
BARGER, WR ;
SNOW, AW .
ANALYTICAL CHEMISTRY, 1990, 62 (18) :1927-1934