Monitoring damage in composite plates from crack initiation to macro-crack propagation combining linear and nonlinear ultrasonic techniques

被引:69
作者
Alnuaimi, Hamad [1 ]
Amjad, Umar [1 ]
Russo, Pietro [2 ]
Lopresto, Valentina [3 ]
Kundu, Tribikram [1 ]
机构
[1] Univ Arizona, Dept Civil & Architectural Engn & Mech, Tucson, AZ 85721 USA
[2] CNR, Inst Polymers Composites & Biomat, Pozzuoli, Italy
[3] Univ Naples Federico II, Dept Chem Mat & Prod Engn, Naples, Italy
来源
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL | 2021年 / 20卷 / 01期
关键词
Composite; elastic wave; damage monitoring; nonlinear ultrasonic; structural health monitoring; NONDESTRUCTIVE EVALUATION; WAVE MODULATION; SPECTROSCOPY; GENERATION;
D O I
10.1177/1475921720922922
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
In this article, a holistic technique for sensing damage initiation, as well as damage progression in composite plates, is presented combining linear and nonlinear ultrasonic techniques. For this investigation, multiple sets of composite plate specimens made of two different composite materials were fabricated to check if the proposed technique works for different types of specimens. The specimens were damaged by impact loading and then inspected by propagating Lamb waves through them. Different failure mechanisms, such as fiber breaks, matrix cracking, debonding, and delamination, cause composite damage. Two groups of composite specimens that were fabricated and damaged were glass fiber-reinforced polymer composite and basalt fiber-reinforced polymer composite. A chirp signal excited by PZT (lead zirconate titanate) transducer was propagated through undamaged and damaged specimens to investigate the effects of varying degrees of damage on the recorded signals. Both linear and nonlinear ultrasonic parameters were extracted from the recorded signals and analyzed. The change in the linear ultrasonic parameters such as the wave speed and attenuation with damage progression were recorded. A new nonlinear ultrasonic parameter, the sideband peak count or sideband peak count-index, is also introduced and calculated from the recorded signals. It is observed that the nonlinear ultrasonic parameter can monitor the early stage of damage progression better than the linear ultrasonic parameters, while some linear ultrasonic parameters are more effective than the nonlinear ultrasonic parameter for monitoring the advanced stage of damage. Therefore, a combination of linear ultrasonic and nonlinear ultrasonic analyses is ideal for the holistic monitoring of the composite panels from the crack nucleation stage to the structural failure stage.
引用
收藏
页码:139 / 150
页数:12
相关论文
共 29 条
[1]   Detection and quantification of diameter reduction due to corrosion in reinforcing steel bars [J].
Amjad, Umar ;
Yadav, Susheel Kumar ;
Kundu, Tribikram .
STRUCTURAL HEALTH MONITORING-AN INTERNATIONAL JOURNAL, 2015, 14 (05) :532-543
[2]   Baseline-free estimation of residual fatigue life using a third order acoustic nonlinear parameter [J].
Amura, Mikael ;
Meo, Michele ;
Amerini, F. .
JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2011, 130 (04) :1829-1837
[3]   On the acoustic nonlinearity of solid-solid contact with pressure-dependent interface stiffness [J].
Biwa, S ;
Nakajima, S ;
Ohno, N .
JOURNAL OF APPLIED MECHANICS-TRANSACTIONS OF THE ASME, 2004, 71 (04) :508-515
[4]   ACOUSTIC HARMONIC-GENERATION AT UNBONDED INTERFACES AND FATIGUE CRACKS [J].
BUCK, O ;
MORRIS, WL ;
RICHARDSON, JM .
APPLIED PHYSICS LETTERS, 1978, 33 (05) :371-373
[5]  
Cantrell JH, 2001, INT J FATIGUE, V23, pS487, DOI 10.1016/S0142-1123(01)00162-1
[6]   Characterization of progressive microcracking in Portland cement mortar using nonlinear ultrasonics [J].
Chen, X. J. ;
Kim, J. -Y. ;
Kurtis, K. E. ;
Qu, J. ;
Shen, C. W. ;
Jacobs, L. J. .
NDT & E INTERNATIONAL, 2008, 41 (02) :112-118
[7]   Vibro-acoustic modulation nondestructive evaluation technique [J].
Donskoy, DM ;
Sutin, AM .
JOURNAL OF INTELLIGENT MATERIAL SYSTEMS AND STRUCTURES, 1998, 9 (09) :765-771
[8]   Nondestructive Monitoring of Ageing of Alkali Resistant Glass Fiber Reinforced Cement (GRC) [J].
Eiras, J. N. ;
Kundu, T. ;
Bonilla, M. ;
Paya, J. .
JOURNAL OF NONDESTRUCTIVE EVALUATION, 2013, 32 (03) :300-314
[9]   Efficient use of Lamb modes for detecting defects in large plates [J].
Ghosh, T ;
Kundu, T ;
Karpur, P .
ULTRASONICS, 1998, 36 (07) :791-801
[10]   Peri-ultrasound for modeling linear and nonlinear ultrasonic response [J].
Hafezi, Mohammad Hadi ;
Alebrahim, Reza ;
Kundu, Tribikram .
ULTRASONICS, 2017, 80 :47-57