Zero collisional frequency shift operation of a caesium fountain clock

被引:0
|
作者
Szymaniec, K. [1 ]
Chalupczak, W. [1 ]
Ovchinnikov, Y. [1 ]
Marra, G. [1 ]
机构
[1] Natl Phys Lab, Teddington TW11 0LW, Middx, England
关键词
D O I
10.1109/CPEM.2008.4574656
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We report preliminary results from a Cs fountain primary frequency standard operated in a regime where the collisional frequency shift is zero. This shift is of opposite sign for the two clock states. The shift is cancelled by equalizing the contributions from the two clock states by adjusting the clock state composition during the microwave interrogation. Design details of, and modifications to, the fountain NPL-CsF2 are described. Attention has been paid to assuring long-term stability of the fountain parameters, especially the atom cloud size and the amplitude of the interrogating microwave field.
引用
收藏
页码:68 / 68
页数:1
相关论文
共 50 条
  • [31] Investigation of cold atom collision frequency shift measured by rapid adiabatic passage in cesium fountain clock
    Guan Yong
    Liu Dan-Dan
    Wang Xin-Liang
    Zhang Hui
    Shi Jun-Ru
    Bai Yang
    Ruan Jun
    Zhang Shou-Gang
    ACTA PHYSICA SINICA, 2020, 69 (14)
  • [32] MEASUREMENT OF Cs-BUFFER GAS COLLISIONAL FREQUENCY SHIFT USING CPT PULSED CLOCK
    Kozlova, O.
    Boudot, R.
    Guerandel, S.
    de Clercq, E.
    2010 CONFERENCE ON PRECISION ELECTROMAGNETIC MEASUREMENTS CPEM, 2010, : 466 - +
  • [33] Collisional frequency shift with a primary frequency standard
    Kajita, M
    ZEITSCHRIFT FUR PHYSIK D-ATOMS MOLECULES AND CLUSTERS, 1997, 41 (01): : 3 - 8
  • [34] Long-term comparison of caesium fountain primary frequency standards
    Parker, Thomas E.
    METROLOGIA, 2010, 47 (01) : 1 - 10
  • [35] The generation of new TA(NIM), which is steered by a NIM4 caesium fountain clock
    Gao Yuan
    Gao Xiaoxun
    Zhang Aimin
    Wang Weibo
    Ning Dayu
    Wang Chen
    Li Dawei
    Liu Xiaojin
    Liu Nianfeng
    Wang Ping
    Li Mingshou
    Lin Pingwei
    Chen Weiliang
    Lin Yige
    Li Tianchu
    METROLOGIA, 2008, 45 (06) : S34 - S37
  • [36] Collisional frequency shifts in 133Cs fountain clocks
    Leo, PJ
    Julienne, PS
    Mies, FH
    Williams, CJ
    PHYSICAL REVIEW LETTERS, 2001, 86 (17) : 3743 - 3746
  • [37] Design and realization of the microwave cavity in the PTB caesium atomic fountain clock CSF1
    Schröder, R
    Hübner, U
    Griebsch, D
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2002, 49 (03) : 383 - 392
  • [38] Experimental Evaluation of the Blackbody Radiation Shift in the Cesium Atomic Fountain Clock
    Yang, Fan
    Wang, Xinliang
    Ruan, Jun
    Shi, Junru
    Fan, Sichen
    Bai, Yang
    Guan, Yong
    Hao, Qiang
    Zhang, Hui
    Liu, Dandan
    Zhang, Shougang
    APPLIED SCIENCES-BASEL, 2022, 12 (01):
  • [39] Time and Frequency Reference Frame to Evaluate Uncertainties of Caesium Fountain Primary Standards
    Boyko, A.
    Domnin, Yu
    Koshelyaevsky, N.
    Sokolova, O.
    PROCEEDINGS OF THE 46TH ANNUAL PRECISE TIME AND TIME INTERVAL SYSTEMS AND APPLICATIONS MEETING, 2014, : 93 - 97
  • [40] Improvements and new evaluation of NIM4 caesium fountain clock at NIM in 2005-2006
    Li Tian-Chu
    Li Ming-Shou
    Lin Ping-Wei
    Wang Ping
    Chen Wei-Liang
    Liu Nian-Feng
    Lin Yi-Ge
    CHINESE PHYSICS LETTERS, 2007, 24 (05) : 1177 - 1179