The native aortic valve reduces paravalvular leak in TAVR patients

被引:3
|
作者
Prisco, Anthony R. [1 ,2 ]
Zhingre-Sanchez, Jorge [2 ,3 ]
Mattison, Lars [2 ,3 ]
Yannopoulos, Demetris [1 ]
Raveendran, Ganesh [1 ]
Iaizzo, Paul A. [2 ]
Gurevich, Sergey [1 ]
机构
[1] Univ Minnesota, Dept Med, Div Cardiol, Minneapolis, MN 55455 USA
[2] Univ Minnesota, Dept Surg, Visible Heart Labs, Minneapolis, MN USA
[3] Univ MN, Dept Biomed Engn, Minneapolis, MN USA
关键词
transcatheter valve replacement; 3D printing; paravalvular leak; computational fluid dynamics; TRANSCATHETER; REPLACEMENT; IMPLANTATION; STENOSIS; REGURGITATION; SIMULATION;
D O I
10.3389/fphys.2022.910016
中图分类号
Q4 [生理学];
学科分类号
071003 ;
摘要
Background: Paravalvular leak (PVL) is a frequent TAVR complication. Prospective identification of patients who are likely to develop PVL after TAVR would likely lead to improved outcomes. Prior studies have used geometric characteristics to predict the likelihood of PVL development, but prediction and quantification has not been done. One of the reasons is that it is difficult to predict the mechanical deformation of the native diseased aortic valve prior to implantation of the prosthetic valve, as existing calcifications likely contribute to the seal between the prosthetic valve and the aortic annulus. However, the relatively amount the native valve plays in preventing PVL is unknown. Methods: A retrospective chart review was conducted identifying patients with mild or greater PVL. One patient who had substantial PVL was identified and a 3D printed (pre-TAVR) aortic root was created. Balloon-expandable TAVR stent frames were implanted within the 3D printed root and a new model was created. Using this geometry, computational fluid dynamics (CFD) simulations were done to quantify PVL. The PVL flow path was iteratively decreased to simulate the space occupied by a crushed native aortic valve and PVL was quantified. Results: PVL was found to decrease as the space occupying the PVL area increased, demonstrating that the native aortic valve contributes to reducing regurgitation. CFD simulations demonstrated that within the patient analyzed, the native valve occupies between 3-40% of the PVL pathway. Conclusion: A priori techniques that predict the development of post TAVR PVL should account for the native diseased valve as our simulations demonstrate that it plays a role in reducing PVL.
引用
收藏
页数:9
相关论文
共 50 条
  • [1] TAVR-in-TAVR with a balloon-expandable valve for paravalvular leak
    Nagasaka, Takashi
    Patel, Vivek
    Koren, Ofir
    Shechter, Alon
    Chakravarty, Tarun
    Cheng, Wen
    Ishii, Hideki
    Jilaihawi, Hasan
    Nakamura, Mamoo
    Makkar, Raj R.
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2024, 11
  • [2] Comparison of paravalvular aortic leak characteristics in the Medtronic CoreValve versus Edwards Sapien Valve: Paravalvular aortic leak characteristics
    Gilbert, Olivia N.
    Choi, Charles H.
    Franzil, Jodie L.
    Caughey, Melissa
    Qureshi, Waqas
    Stacey, R. Brandon
    Pu, Min
    Applegate, Robert J.
    Gandhi, Sanjay K.
    Zhao, David X. M.
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2018, 92 (05) : 972 - 980
  • [3] Impact of Valve Size on Paravalvular Leak and Valve Hemodynamics in Patients With Borderline Size Aortic Valve Annulus
    Talmor-Barkan, Yeela
    Kornowski, Ran
    Bar, Noam
    Ben-Shoshan, Jeremy
    Vaknin-Assa, Hanna
    Hamdan, Ashraf
    Kruchin, Boris
    Barbash, Israel M.
    Danenberg, Haim
    Perlman, Gidon Y.
    Konigstein, Maayan
    Finkelstein, Ariel
    Steinvil, Arie
    Merdler, Ilan
    Segev, Amit
    Barsheshet, Alon
    Codner, Pablo
    FRONTIERS IN CARDIOVASCULAR MEDICINE, 2022, 9
  • [4] Paravalvular leak closure of a native aortic valve for cardiogenic shock post valvular surgery
    Lochy, Stijn
    Galloo, Xavier
    Droogmans, Steven
    Eeckhout, Eric
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2024, 104 (04) : 858 - 861
  • [5] Numerical Parametric Study of Paravalvular Leak Following a Transcatheter Aortic Valve Deployment Into a Patient-Specific Aortic Root
    Mao, Wenbin
    Wang, Qian
    Kodali, Susheel
    Sun, Wei
    JOURNAL OF BIOMECHANICAL ENGINEERING-TRANSACTIONS OF THE ASME, 2018, 140 (10):
  • [6] Paravalvular leak after transcatheter aortic valve replacement
    Genereux, P.
    Kodali, S.
    Hahn, R.
    Nazif, T.
    Williams, M. R.
    Leon, M. B.
    MINERVA CARDIOANGIOLOGICA, 2013, 61 (05): : 529 - 537
  • [7] Risk factors for paravalvular leak after transcatheter aortic valve replacement
    Pollari, Francesco
    Dell'Aquila, Angelo Maria
    Soehn, Claudius
    Marianowicz, Jill
    Wiehofsky, Pia
    Schwab, Johannes
    Pauschinger, Matthias
    Hitzl, Wolfgang
    Fischlein, Theodor
    Pfeiffer, Steffen
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2019, 157 (04) : 1406 - +
  • [8] Evaluating paravalvular leak after TAVR
    Gopalakrishnan, Deepika
    Gopal, Ambarish
    Grayburn, Paul A.
    HEART, 2014, 100 (24) : 1903 - 1904
  • [9] Bioprosthetic Aortic Paravalvular Leak: Is Valve-in-Valve Another Solution?
    Tandar, Anwar
    Bull, David A.
    Welt, Frederick G. P.
    JOURNAL OF INVASIVE CARDIOLOGY, 2017, 29 (01) : E1 - E7
  • [10] Percutaneous Paravalvular Leak Closure for Balloon-Expandable Transcatheter Aortic Valve Replacement: A Comparison With Surgical Aortic Valve Replacement Paravalvular Leak Closure
    Okuyama, Kazuaki
    Jilaihawi, Hasan
    Kashif, Mohammad
    Soni, Vikas
    Matsumoto, Takashi
    Yeow, Wen Loong
    Nakamura, Mamoo
    Cheng, Wen
    Kar, Saibal
    Makkar, Raj R.
    JOURNAL OF INVASIVE CARDIOLOGY, 2015, 27 (06) : 284 - 290