Exposure to indoor air contaminants in school buildings with and without reported indoor air quality problems

被引:32
作者
Vornanen-Winqvist, Camilla [1 ]
Jarvi, Kati [1 ]
Andersson, Maria A. [1 ]
Duchaine, Caroline [2 ,3 ]
Letourneau, Valerie [3 ]
Kedves, Orsolya [4 ]
Kredics, Laszlo [4 ]
Mikkola, Raimo [1 ]
Kurnitski, Jarek [1 ,5 ]
Salonen, Heidi [1 ]
机构
[1] Aalto Univ, Dept Civil Engn, POB 12100, FI-00076 Aalto, Finland
[2] Univ Laval, Dept Biochim Microbiol & Bioinformat, 2325 Rue Univ, Quebec City, PQ G1V 0A6, Canada
[3] Inst Univ Cardiol & Pneumol Quebec, Ctr Rech, 2725 Chemin, Ste Foy, PQ G1V 4G5, Canada
[4] Univ Szeged, Fac Sci & Informat, Dept Microbiol, Kozep Fasor 52, H-6726 Szeged, Hungary
[5] Tallinn Univ Technol, Dept Civil Engn & Architecture, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
基金
芬兰科学院;
关键词
Indoor air quality; School; Trichoderma; Microbes; Online questionnaire; ENDOTOXIN EXPOSURE; RELATIVE-HUMIDITY; MOISTURE-DAMAGE; SYMPTOMS; HEALTH; OFFICE; DUST; ENVIRONMENTS; FUNGAL; IMPACT;
D O I
10.1016/j.envint.2020.105781
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Reported indoor air quality (IAQ) complaints are common even in relatively new or renovated school buildings in Finland. However, detecting the causes for complaints with commonly used indoor air measurements is difficult. This study presents data on perceived and measured IAQ in six comprehensive school buildings in Finland. The aim of this study was to discover the possible differences of perceived and measured IAQ between schools with reported IAQ complaints and schools without reported IAQ complaints. The initial categorisation of schools with ('problematic schools') and without ('comparison schools') complaints was ensured via a validated indoor climate survey and a recently developed online questionnaire, which were completed by 186 teachers and 1268 students from the six schools. IAQ measurements of physical parameters, gaseous pollutants, particulate matter and bioaerosols were conducted in four problematic school buildings (26 classrooms) and two com- parison school buildings (12 classrooms). Using air sampling as well as exhaust air filters and classroom settled dust to detect the presence of elevated concentrations of airborne cultivable microbes and pathogenic, toxigenic and mycoparasitic Trichoderma strains were the most indicative methods in distinguishing problematic schools from comparison schools. Other IAQ-related measurements did not detect clear differences between problematic and comparison schools, as the concentration levels were very low. The results indicate that the complaints reported by occupants could have been related to excess moisture or mould problems that had not been found or repaired. Ventilation pressure condition investigations and simultaneous exhaust and supply air filter dust culture should be addressed precisely in future studies.
引用
收藏
页数:14
相关论文
共 50 条
  • [41] Elderly exposure to indoor air pollutants
    Almeida-Silva, M.
    Wolterbeek, H. T.
    Almeida, S. M.
    ATMOSPHERIC ENVIRONMENT, 2014, 85 : 54 - 63
  • [42] Indoor Air Problems and Hoarseness in Children
    Kallvik, Emma
    Putus, Tuula
    Simberg, Susanna
    JOURNAL OF VOICE, 2016, 30 (01) : 109 - 113
  • [43] Investigation of Indoor Air Quality in Primary School Classrooms
    Hou, Yuefei
    Liu, Junjie
    Li, Jiayu
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 830 - 837
  • [44] Indoor Air Quality in Healthcare and Care Facilities: Chemical Pollutants and Microbiological Contaminants
    Baudet, Alexandre
    Baures, Estelle
    Guegan, Helene
    Blanchard, Olivier
    Guillaso, Monique
    Le Cann, Pierre
    Gangneux, Jean-Pierre
    Florentin, Arnaud
    ATMOSPHERE, 2021, 12 (10)
  • [45] A study on indoor air quality of urban residential buildings in China
    Yoshino, H
    Zhao, J
    Yoshino, Y
    Kumagai, K
    Ni, YY
    Li, ZH
    Liu, J
    Shigeno, T
    Miyasaka, H
    Yanagizawa, Y
    BUILT ENVIRONMENT AND PUBLIC HEALTH, PROCEEDINGS, 2004, : 208 - 215
  • [46] Organic compounds in indoor air - their relevance for perceived indoor air quality?
    Wolkoff, P
    Nielsen, GD
    ATMOSPHERIC ENVIRONMENT, 2001, 35 (26) : 4407 - 4417
  • [47] Students' school-level symptoms mediate the relationship between a school's observed moisture problems and students' subjective perceptions of indoor air quality
    Finell, Eerika
    Tolvanen, Asko
    Ikonen, Riikka
    Pekkanen, Juha
    Stahl, Timo
    INDOOR AIR, 2021, 31 (01) : 40 - 50
  • [48] Formation of Quality Indoor Air in Wooden Buildings with Domestic Wood
    Yamashita, Rie
    Sakuragawa, Satoshi
    Saito, Yukie
    Watanabe, Hiromu
    Yasumura, Motoi
    MOKUZAI GAKKAISHI, 2017, 63 (02): : 86 - 97
  • [49] A study on indoor air quality of urban residential buildings in China
    Zhao, J
    Yoshino, H
    Yoshino, Y
    Kumagai, K
    Ni, Y
    Li, Z
    Liu, J
    Shigeno, T
    Miyasaka, H
    Yanagisawa, Y
    INDOOR AIR 2005: PROCEEDINGS OF THE 10TH INTERNATIONAL CONFERENCE ON INDOOR AIR QUALITY AND CLIMATE, VOLS 1-5, 2005, : 543 - 547
  • [50] Indoor air quality certification scheme for Hong Kong buildings
    Burnett, J