Exposure to indoor air contaminants in school buildings with and without reported indoor air quality problems

被引:32
作者
Vornanen-Winqvist, Camilla [1 ]
Jarvi, Kati [1 ]
Andersson, Maria A. [1 ]
Duchaine, Caroline [2 ,3 ]
Letourneau, Valerie [3 ]
Kedves, Orsolya [4 ]
Kredics, Laszlo [4 ]
Mikkola, Raimo [1 ]
Kurnitski, Jarek [1 ,5 ]
Salonen, Heidi [1 ]
机构
[1] Aalto Univ, Dept Civil Engn, POB 12100, FI-00076 Aalto, Finland
[2] Univ Laval, Dept Biochim Microbiol & Bioinformat, 2325 Rue Univ, Quebec City, PQ G1V 0A6, Canada
[3] Inst Univ Cardiol & Pneumol Quebec, Ctr Rech, 2725 Chemin, Ste Foy, PQ G1V 4G5, Canada
[4] Univ Szeged, Fac Sci & Informat, Dept Microbiol, Kozep Fasor 52, H-6726 Szeged, Hungary
[5] Tallinn Univ Technol, Dept Civil Engn & Architecture, Ehitajate Tee 5, EE-19086 Tallinn, Estonia
基金
芬兰科学院;
关键词
Indoor air quality; School; Trichoderma; Microbes; Online questionnaire; ENDOTOXIN EXPOSURE; RELATIVE-HUMIDITY; MOISTURE-DAMAGE; SYMPTOMS; HEALTH; OFFICE; DUST; ENVIRONMENTS; FUNGAL; IMPACT;
D O I
10.1016/j.envint.2020.105781
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Reported indoor air quality (IAQ) complaints are common even in relatively new or renovated school buildings in Finland. However, detecting the causes for complaints with commonly used indoor air measurements is difficult. This study presents data on perceived and measured IAQ in six comprehensive school buildings in Finland. The aim of this study was to discover the possible differences of perceived and measured IAQ between schools with reported IAQ complaints and schools without reported IAQ complaints. The initial categorisation of schools with ('problematic schools') and without ('comparison schools') complaints was ensured via a validated indoor climate survey and a recently developed online questionnaire, which were completed by 186 teachers and 1268 students from the six schools. IAQ measurements of physical parameters, gaseous pollutants, particulate matter and bioaerosols were conducted in four problematic school buildings (26 classrooms) and two com- parison school buildings (12 classrooms). Using air sampling as well as exhaust air filters and classroom settled dust to detect the presence of elevated concentrations of airborne cultivable microbes and pathogenic, toxigenic and mycoparasitic Trichoderma strains were the most indicative methods in distinguishing problematic schools from comparison schools. Other IAQ-related measurements did not detect clear differences between problematic and comparison schools, as the concentration levels were very low. The results indicate that the complaints reported by occupants could have been related to excess moisture or mould problems that had not been found or repaired. Ventilation pressure condition investigations and simultaneous exhaust and supply air filter dust culture should be addressed precisely in future studies.
引用
收藏
页数:14
相关论文
共 50 条
  • [21] FUNGI AS CONTAMINANTS IN INDOOR AIR
    MILLER, JD
    ATMOSPHERIC ENVIRONMENT PART A-GENERAL TOPICS, 1992, 26 (12): : 2163 - 2172
  • [22] Methodology for the in situ characterisation of soil vapor contaminants and their impact on the indoor air quality of buildings
    Collignan, Bernard
    Diallo, Thierno M. O.
    Traverse, Sylvie
    Chastanet, Juliette
    Abadie, Marc
    Powaga, Emilie
    Hulot, Corinne
    Romani, Zaid
    Allard, Francis
    Grasset, Marie
    BUILDING AND ENVIRONMENT, 2020, 177
  • [23] Indoor Air Quality and Strategic Decision Making
    Kuenn, Steffen
    Palacios, Juan
    Pestel, Nico
    MANAGEMENT SCIENCE, 2023, 69 (09) : 5354 - 5377
  • [24] Ten questions concerning green buildings and indoor air quality
    Anne Steinemann
    Pawel Wargocki
    Behzad Rismanchi
    侯恩哲
    建筑节能, 2017, 45 (02) : 60 - 60
  • [25] The Improvement of Indoor Air Quality in Residential Buildings in Dubai, UAE
    Jung, Chuloh
    Awad, Jihad
    BUILDINGS, 2021, 11 (06)
  • [26] Indoor Air Quality: A Bibliometric Study
    Pierpaoli, Mattia
    Ruello, Maria Letizia
    SUSTAINABILITY, 2018, 10 (11)
  • [27] Indoor air quality and its health effects in offices and school buildings in the Yangtze River Delta
    Sun, Chanjuan
    Chen, Jingyu
    Hong, Shijie
    Zhang, Yinping
    Kan, Haidong
    Zhao, Zhuohui
    Deng, Furong
    Zeng, Xiangang
    Sun, Yuexia
    Qian, Hua
    Liu, Wei
    Mo, Jinhan
    Liu, Ningrui
    Guo, Jianguo
    Zheng, Xiaohong
    Su, Chunxiao
    Zou, Zhijun
    Li, Hao
    Huang, Chen
    AIR QUALITY ATMOSPHERE AND HEALTH, 2023, 16 (08) : 1571 - 1586
  • [28] Investigation on Indoor Air Quality in Tianjin Residential Buildings
    Sun, Yuexia
    Cheng, Rongsai
    Hou, Jing
    Song, Yangrui
    Luo, Shugang
    10TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING, ISHVAC2017, 2017, 205 : 3811 - 3815
  • [29] OUTDOOR AIR CONTAMINANTS AND INDOOR AIR-QUALITY UNDER TRANSIENT CONDITIONS
    EKBERG, LE
    INDOOR AIR-INTERNATIONAL JOURNAL OF INDOOR AIR QUALITY AND CLIMATE, 1994, 4 (03): : 189 - 196
  • [30] Investigation of indoor and outdoor air quality of the classrooms at a school in Serbia
    Jovanovic, Marina
    Vucicevic, Biljana
    Turanjanin, Valentina
    Zivkovic, Marija
    Spasojevic, Vuk
    ENERGY, 2014, 77 : 42 - 48