Continuous cuffless and non-invasive measurement of arterial blood pressure-concepts and future perspectives

被引:23
作者
Pilz, Niklas [1 ,2 ,3 ,4 ]
Patzak, Andreas [1 ,2 ,3 ,4 ]
Bothe, Tomas L. [1 ,2 ,3 ,4 ]
机构
[1] Univ Med Berlin, Charitepl 1, D-10117 Berlin, Germany
[2] Free Univ Berlin, Charitepl 1, D-10117 Berlin, Germany
[3] Humboldt Univ, Charitepl 1, D-10117 Berlin, Germany
[4] Inst Translat Physiol, Charitepl 1, D-10117 Berlin, Germany
关键词
Blood pressure measurement; pulse wave velocity; deep learning; hypertension; pulse transit time; PULSE-WAVE VELOCITY; REGRESSION; TIME;
D O I
10.1080/08037051.2022.2128716
中图分类号
R6 [外科学];
学科分类号
1002 ; 100210 ;
摘要
Hypertension diagnosis is one of the most common and important procedures in everyday clinical practice. Its applicability depends on correct and comparable measurements. Cuff-based measurement paradigms have dominated ambulatory blood pressure (BP) measurements for multiple decades. Cuffless and non-invasive methods may offer various advantages, such as a continuous and undisturbing measurement character. This review presents a conceptual overview of recent advances in the field of cuffless measurement paradigms and possible future developments which would enable cuffless beat-to-beat BP estimation paradigms to become clinically viable. It was refrained from a direct comparison between most studies and focussed on a conceptual merger of the ideas and conclusions presented in landmark scientific literature. There are two main approaches to cuffless beat-to-beat BP estimation represented in the scientific literature: First, models based on the physiological understanding of the cardiovascular system, mostly reliant on the pulse wave velocity combined with additional parameters. Second, models based on Deep Learning techniques, which have already shown great performance in various other medical fields. This review wants to present the advantages and limitations of each approach. Following this, the conceptional idea of unifying the benefits of physiological understanding and Deep Learning techniques for beat-to-beat BP estimation is presented. This could lead to a generalised and uniform solution for cuffless beat-to-beat BP estimations. This would not only make them an attractive clinical complement or even alternative to conventional cuff-based measurement paradigms but would substantially change how we think about BP as a fundamental marker of cardiovascular medicine. PLAIN LANGUAGE SUMMARY This concept review wants to highlight the current state of non-invasive cuffless continuous blood pressure estimation. Cuffless blood pressure measurement devices usually rely on pulse wave velocity. Pulse wave velocity is mostly calculated via measuring pulse arrival time. Using pulse transit time instead of pulse arrival time showed improved results. Additional biomarkers like heart rate, photoplethysmogram intensity ratio or heart rate power spectrum ratio can be used to improve measurement precision. For cuffless and cuff-based devices intended for 24-hour BP measurements, a more refined validation protocol is required. The ESH assesses the measurement accuracy of cuffless devices as unclear and does not recommend hypertension diagnosis based on cuffless devices. Machine Learning and Deep Learning applications are a powerful tool to generate complex algorithms, which can be used to estimate blood pressure. Selecting biomarkers like pulse wave velocity, heart rate, etc. as input features for Deep Learning systems would be a very promising approach to measure blood pressure more precise.
引用
收藏
页码:254 / 269
页数:16
相关论文
共 69 条
  • [1] Mode of blood pressure monitoring and morbidity after noncardiac surgery A prospective multicentre observational cohort study
    Abbott, Tom E. F.
    Howell, Simon
    Pearse, Rupert M.
    Ackland, Gareth L.
    [J]. EUROPEAN JOURNAL OF ANAESTHESIOLOGY, 2021, 38 (05) : 468 - 476
  • [2] The Effect of Measuring Ambulatory Blood Pressure on Nighttime Sleep and Daytime Activity-Implications for Dipping
    Agarwal, Rajiv
    Light, Robert P.
    [J]. CLINICAL JOURNAL OF THE AMERICAN SOCIETY OF NEPHROLOGY, 2010, 5 (02): : 281 - 285
  • [3] POWER SPECTRUM ANALYSIS OF HEART-RATE FLUCTUATION - A QUANTITATIVE PROBE OF BEAT-TO-BEAT CARDIOVASCULAR CONTROL
    AKSELROD, S
    GORDON, D
    UBEL, FA
    SHANNON, DC
    BARGER, AC
    COHEN, RJ
    [J]. SCIENCE, 1981, 213 (4504) : 220 - 222
  • [4] Medical Image Analysis using Convolutional Neural Networks: A Review
    Anwar, Syed Muhammad
    Majid, Muhammad
    Qayyum, Adnan
    Awais, Muhammad
    Alnowami, Majdi
    Khan, Muhammad Khurram
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2018, 42 (11)
  • [5] Tree-Based Analysis A Practical Approach to Create Clinical Decision-Making Tools
    Banerjee, Mousumi
    Reynolds, Evan
    Andersson, Hedvig B.
    Nallamothu, Brahmajee K.
    [J]. CIRCULATION-CARDIOVASCULAR QUALITY AND OUTCOMES, 2019, 12 (05):
  • [6] Effects of Newer Antidiabetic Drugs on Endothelial Function and Arterial Stiffness: A Systematic Review and Meta-Analysis
    Batzias, Konstantinos
    Antonopoulos, Alexios S.
    Oikonomou, Evangelos
    Siasos, Gerasimos
    Bletsa, Evanthia
    Stampouloglou, Panagiota K.
    Mistakidi, Chara-Vasiliki
    Noutsou, Marina
    Katsiki, Niki
    Karopoulos, Periklis
    Charalambous, Georgios
    Thanopoulou, Anastasia
    Tentolouris, Nicholas
    Tousoulis, Dimitris
    [J]. JOURNAL OF DIABETES RESEARCH, 2018, 2018
  • [7] Pulse Arrival Time Segmentation Into Cardiac and Vascular Intervals - Implications for Pulse Wave Velocity and Blood Pressure Estimation
    Beutel, Fabian
    Van Hoof, Chris
    Rottenberg, Xavier
    Reesink, Koen
    Hermeling, Evelien
    [J]. IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2021, 68 (09) : 2810 - 2820
  • [8] Validation of the Somnotouch-NIBP noninvasive continuous blood pressure monitor according to the European Society of Hypertension International Protocol revision 2010
    Bilo, Grzegorz
    Zorzi, Cristina
    Munera, Juan E. Ochoa
    Torlasco, Camilla
    Giuli, Valentina
    Parati, Gianfranco
    [J]. BLOOD PRESSURE MONITORING, 2015, 20 (05) : 291 - 294
  • [9] Conventional pulse transit times as markers of blood pressure changes in humans
    Block, Robert C.
    Yavarimanesh, Mohammad
    Natarajan, Keerthana
    Carek, Andrew
    Mousavi, Azin
    Chandrasekhar, Anand
    Kim, Chang-Sei
    Zhu, Junxi
    Schifitto, Giovanni
    Mestha, Lalit K.
    Inan, Omer T.
    Hahn, Jin-Oh
    Mukkamala, Ramakrishna
    [J]. SCIENTIFIC REPORTS, 2020, 10 (01)
  • [10] The B-Score is a novel metric for measuring the true performance of blood pressure estimation models
    Bothe, Tomas L.
    Patzak, Andreas
    Pilz, Niklas
    [J]. SCIENTIFIC REPORTS, 2022, 12 (01)