Avoiding Patient-Prosthesis Mismatch Is TAVI a New Solution?

被引:1
作者
Stewart, William J. [1 ]
Rodriguez, L. Leonardo [1 ]
机构
[1] Cleveland Clin Fdn, Dept Cardiovasc Med, Sect Cardiovasc Imaging, Cleveland, OH 44195 USA
关键词
aortic stenosis; Doppler aortic valve area; prosthesis-patient mismatch; transcatheter aortic valve implantation; AORTIC-VALVE-REPLACEMENT; LONG-TERM SURVIVAL; DOPPLER ULTRASOUND; IMPACT; AREA; ECHOCARDIOGRAPHY; TRANSCATHETER; GRADIENT; STENOSIS; RECOVERY;
D O I
10.1016/j.jcmg.2011.08.004
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:1063 / 1066
页数:4
相关论文
共 21 条
  • [1] EFFECT OF CATHETER POSITIONING ON THE VARIABILITY OF MEASURED GRADIENT IN AORTIC-STENOSIS
    ASSEY, ME
    ZILE, MR
    USHER, BW
    KARAVAN, MP
    CARABELLO, BA
    [J]. CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1993, 30 (04): : 287 - 292
  • [2] EFFECT OF PROSTHETIC AORTIC-VALVE DESIGN ON THE DOPPLER-CATHETER GRADIENT CORRELATION - AN INVITRO STUDY OF NORMAL ST-JUDE, MEDTRONIC-HALL, STARR-EDWARDS AND HANCOCK VALVES
    BAUMGARTNER, H
    KHAN, S
    DEROBERTIS, M
    CZER, L
    MAURER, G
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1992, 19 (02) : 324 - 332
  • [3] DISCREPANCIES BETWEEN DOPPLER AND CATHETER GRADIENTS IN AORTIC PROSTHETIC VALVES INVITRO - A MANIFESTATION OF LOCALIZED GRADIENTS AND PRESSURE RECOVERY
    BAUMGARTNER, H
    KHAN, S
    DEROBERTIS, M
    CZER, L
    MAURER, G
    [J]. CIRCULATION, 1990, 82 (04) : 1467 - 1475
  • [4] Prosthesis size and long-term survival after aortic valve replacement
    Blackstone, EH
    Cosgrove, DM
    Jamieson, WRE
    Birkmeyer, NJ
    Lemmer, JH
    Miller, DC
    Butchart, EG
    Rizzoli, G
    Yacoub, M
    Chai, AK
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2003, 126 (03) : 783 - 796
  • [5] Validation and Characterization of Transcatheter Aortic Valve Effective Orifice Area Measured by Doppler Echocardiography
    Clavel, Marie-Annick
    Rodes-Cabau, Josep
    Dumont, Eric
    Bagur, Rodrigo
    Bergeron, Sebastien
    De Larochelliere, Robert
    Doyle, Daniel
    Larose, Eric
    Dumesnil, Jean G.
    Pibarot, Philippe
    [J]. JACC-CARDIOVASCULAR IMAGING, 2011, 4 (10) : 1053 - 1062
  • [6] Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis
    Clavel, Marie-Annick
    Webb, John G.
    Pibarot, Philippe
    Altwegg, Lukas
    Dumont, Eric
    Thompson, Chris
    De Larochelliere, Robert
    Doyle, Daniel
    Masson, Jean-Bernard
    Bergeron, Sebastien
    Bertrand, Olivier F.
    Rodes-Cabau, Josep
    [J]. JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2009, 53 (20) : 1883 - 1891
  • [7] Prosthesis-patient mismatch after transcatheter aortic valve implantation with the Medtronic-Corevalve bioprosthesis
    Jilaihawi, Hasan
    Chin, Derek
    Spyt, Tomasz
    Jeilan, Mohamed
    Vasa-Nicotera, Mariuca
    Bence, Johan
    Logtens, Elaine
    Kovac, Jan
    [J]. EUROPEAN HEART JOURNAL, 2010, 31 (07) : 857 - 864
  • [8] Impact of prosthesis - Patient size on functional recovery after aortic valve replacement
    Koch, CG
    Khandwala, F
    Estafanous, FG
    Loop, FD
    Blackstone, EH
    [J]. CIRCULATION, 2005, 111 (24) : 3221 - 3229
  • [9] Prosthesis-patient mismatch affects long-term survival after mechanical valve replacement
    Kohsaka, Shun
    Mohan, Shaulnie
    Virani, Salim
    Lee, Vei-Vei
    Contreras, Ariadna
    Reul, George J.
    Coulter, Stephanie A.
    [J]. JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2008, 135 (05) : 1076 - 1080
  • [10] Assessment of small-diameter aortic mechanical prostheses - Physiological relevance of the Doppler gradient, utility of flow augmentation, and limitations of orifice area estimation
    Marcus, RH
    Heinrich, RS
    Bednarz, J
    Lupovitch, S
    Abruzzo, J
    Borok, R
    Vandenberg, B
    Kerber, RE
    Piccione, W
    Yoganathan, AP
    Lang, RM
    [J]. CIRCULATION, 1998, 98 (09) : 866 - 872