A Bifunctional Fully Integrated Wearable Tracker for Epidermal Sweat and Wound Exudate Multiple Biomarkers Monitoring

被引:51
作者
Pei, Xinyi [1 ]
Sun, Mimi [1 ]
Wang, Jingjuan [1 ]
Bai, Jing [1 ]
Bo, Xiangjie [1 ]
Zhou, Ming [1 ]
机构
[1] Northeast Normal Univ, Key Lab Polyoxometalate & Reticular Mat Chem, Minist Educ,Anal & Testing Ctr,Dept Chem, Key Lab Nanobiosensing & Nanobioanal Univ Jilin P, Changchun 130024, Jilin, Peoples R China
基金
中国国家自然科学基金;
关键词
epidermal; fully integrated; sweat; wearable sensors; wound exudate; ORDERED MESOPOROUS CARBON; URIC-ACID;
D O I
10.1002/smll.202205061
中图分类号
O6 [化学];
学科分类号
0703 ;
摘要
Fully integrated wearable electronics that combine the extraordinary feature of incessant and on-body operation with the distinctive external equipment-free trait are the ultimate goal of modern wearables. Epidermal sweat and wound exudate, as two noninvasively accessible biofluids on/surrounding the skin, reflect underlying health conditions. However, the design of universal wearable sensors with the bifunctional capability to monitor both epidermal secretions is still a challenge. Here, a single bifunctional fully integrated wearable tracker for wirelessly, simultaneously, and dynamically in situ measuring multiple epidermal sweat or wound exudate biomarkers is propos. Considering the electrolytes (e.g., Na+, K+, and H+) and metabolites (e.g., uric acid (UA)) levels in sweat or wound exudate may correlate with health or wound conditions, the dynamic and skin-on tracking of the biomarkers of Na+, K+, pH, and UA levels in sweat under subjects' exercise and in wound exudate during subjects' wound healing are performed through the seamless integration of microfluidic, sensing, and electronic modules. Its applicability is evaluated for noninvasive hyperuricemia management in hyperuricemia/healthy subjects through a purine-rich intake test and for wound management in subjects' infected wounds through a control medical treatment.
引用
收藏
页数:11
相关论文
共 53 条
[1]   Statistics notes - Standard deviations and standard errors [J].
Altman, DG ;
Bland, JM .
BRITISH MEDICAL JOURNAL, 2005, 331 (7521) :903-903
[2]  
Baker Lindsay B, 2019, Temperature (Austin), V6, P211, DOI 10.1080/23328940.2019.1632145
[3]   Sweat-activated biocompatible batteries for epidermal electronic and microfluidic systems [J].
Bandodkar, A. J. ;
Lee, S. P. ;
Huang, I ;
Li, W. ;
Wang, S. ;
Su, C-J ;
Jeang, W. J. ;
Hang, T. ;
Mehta, S. ;
Nyberg, N. ;
Gutruf, P. ;
Choi, J. ;
Koo, J. ;
Reeder, J. T. ;
Tseng, R. ;
Ghaffari, R. ;
Rogers, J. A. .
NATURE ELECTRONICS, 2020, 3 (09) :554-+
[4]   Wearable sweat sensors [J].
Bariya, Mallika ;
Nyein, Hnin Yin Yin ;
Javey, Ali .
NATURE ELECTRONICS, 2018, 1 (03) :160-171
[5]   The management of hyperuricemia: back to the pathophysiology of uric acid [J].
Borghi, Claudio .
CURRENT MEDICAL RESEARCH AND OPINION, 2017, 33 :1-4
[6]   Achievements and Challenges for Real-Time Sensing of Analytes in Sweat within Wearable Platforms [J].
Brothers, Michael C. ;
DeBrosse, Madeleine ;
Grigsby, Claude C. ;
Naik, Rajesh R. ;
Hussain, Saber M. ;
Heikenfeld, Jason ;
Kim, Steve S. .
ACCOUNTS OF CHEMICAL RESEARCH, 2019, 52 (02) :297-306
[7]   Na+ secretion rate increases proportionally more than the Na+ reabsorption rate with increases in sweat rate [J].
Buono, Michael J. ;
Claros, Ryan ;
DeBoer, Teshina ;
Wong, Janine .
JOURNAL OF APPLIED PHYSIOLOGY, 2008, 105 (04) :1044-1048
[8]   A fully integrated reprogrammable memristor-CMOS system for efficient multiply-accumulate operations [J].
Cai, Fuxi ;
Correll, Justin M. ;
Lee, Seung Hwan ;
Lim, Yong ;
Bothra, Vishishtha ;
Zhang, Zhengya ;
Flynn, Michael P. ;
Lu, Wei D. .
NATURE ELECTRONICS, 2019, 2 (07) :290-299
[9]   Fully integrated parity-time-symmetric electronics [J].
Cao, Weidong ;
Wang, Changqing ;
Chen, Weijian ;
Hu, Song ;
Wang, Hua ;
Yang, Lan ;
Zhang, Xuan .
NATURE NANOTECHNOLOGY, 2022, 17 (03) :262-+
[10]   Electrogenic Bacteria Promise New Opportunities for Powering, Sensing, and Synthesizing [J].
Choi, Seokheun .
SMALL, 2022, 18 (18)