Robust Optimization of Dose-Volume Metrics for Prostate HDR-Brachytherapy Incorporating Target and OAR Volume Delineation Uncertainties

被引:13
作者
Balvert, Marleen [1 ,2 ,3 ]
den Hertog, Dick [1 ]
Hoffmann, Aswin L. [4 ,5 ,6 ]
机构
[1] Tilburg Univ, Ctr Econ Res CentER, Dept Econometr & Operat Res, NL-5000 LE Tilburg, Netherlands
[2] Ctr Wiskunde Informat, NL-1098 XG Amsterdam, Netherlands
[3] Univ Utrecht, Theoret Biol & Bioinformat, NL-3508 TC Utrecht, Netherlands
[4] Helmholtz Zentrum Dresden Rossendorf, Inst Radiooncol, Dresden, Germany
[5] Tech Univ Dresden, Univ Hosp Carl Gustav Carus, Dept Radiotherapy & Radiooncol, Dresden, Germany
[6] Maastricht Univ, Med Ctr, Dept Radiat Oncol MAASTRO, GROW Sch Oncol & Dev Biol, Maastricht, Netherlands
关键词
brachytherapy; delineation uncertainties; mixed-integer linear optimization; robust optimization; tratment planning; PLAN QUALITY; RADIOTHERAPY; CT; RECOMMENDATIONS; GUIDELINES; INCLUSION; DOSIMETRY; MARGINS; IMPACT; CANCER;
D O I
10.1287/ijoc.2018.0815
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
In radiation therapy planning, uncertainties in the definition of the target volume yield a risk of underdosing the tumor. The traditional corrective action in the context of external beam radiotherapy (EBRT) expands the clinical target volume (CTV) with an isotropic margin to obtain the planning target volume (PTV). However, the EBRT-based PTV concept is not directly applicable to brachytherapy (BT) since it can lead to undesirable dose escalation. Here, we present a treatment plan optimization model that uses worst-case robust optimization to account for delineation uncertainties in interstitial high-dose-rate BT of the prostate. A scenario-based method was developed that handles uncertainties in index sets. Heuristics were included to reduce the calculation times to acceptable proportions. The approach was extended to account for delineation uncertainties of an organ at risk (OAR) as well. The method was applied on data from prostate cancer patients and evaluated in terms of commonly used dosimetric performance criteria for the CTV and relevant OARs. The robust optimization approach was compared against the classical PTV margin concept and against a scenario-based CTV margin approach. The results show that the scenario-based margin and the robust optimization method are capable of reducing the risk of underdosage to the tumor. As expected, the scenario-based CTV margin approach leads to dose escalation within the target, whereas this can be prevented with the robust model. For cases where rectum sparing was a binding restriction, including uncertainties in rectum delineation in the planning model led to a reduced risk of a rectum overdose, and in some cases, to reduced target coverage.
引用
收藏
页码:100 / 114
页数:15
相关论文
共 38 条
[1]  
[Anonymous], [No title captured]
[2]   Dwell time modulation restrictions do not necessarily improve treatment plan quality for prostate HDR brachytherapy [J].
Balvert, Marleen ;
Gorissen, Bram L. ;
den Hertog, Dick ;
Hoffmann, Aswin L. .
PHYSICS IN MEDICINE AND BIOLOGY, 2015, 60 (02) :537-548
[3]  
BenTal A, 2009, PRINC SER APPL MATH, P1
[4]   Computing robust basestock levels [J].
Bienstock, Daniel ;
Ozbay, Nuri .
DISCRETE OPTIMIZATION, 2008, 5 (02) :389-414
[5]   Probabilistic objective functions for margin-less IMRT planning [J].
Bohoslavsky, Roman ;
Witte, Marnix G. ;
Janssen, Tomas M. ;
van Herk, Marcel .
PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (11) :3563-3580
[6]   Robust Management of Motion Uncertainty in Intensity-Modulated Radiation Therapy [J].
Bortfeld, Thomas ;
Chan, Timothy C. Y. ;
Trofimov, Alexei ;
Tsitsiklis, John N. .
OPERATIONS RESEARCH, 2008, 56 (06) :1461-1473
[7]   A robust approach to IMRT optimization [J].
Chan, TCY ;
Bortfeld, T ;
Tsitsiklis, JN .
PHYSICS IN MEDICINE AND BIOLOGY, 2006, 51 (10) :2567-2583
[8]   Including robustness in multi-criteria optimization for intensity-modulated proton therapy [J].
Chen, Wei ;
Unkelbach, Jan ;
Trofimov, Alexei ;
Madden, Thomas ;
Kooy, Hanne ;
Bortfeld, Thomas ;
Craft, David .
PHYSICS IN MEDICINE AND BIOLOGY, 2012, 57 (03) :591-608
[9]   Robust optimization for intensity modulated radiation therapy treatment planning under uncertainty [J].
Chu, M ;
Zinchenko, Y ;
Henderson, SG ;
Sharpe, MB .
PHYSICS IN MEDICINE AND BIOLOGY, 2005, 50 (23) :5463-5477
[10]   Dose optimization in high-dose-rate brachytherapy: A literature review of quantitative models from 1990 to 2010 [J].
De Boecka, L. ;
Belien, J. ;
Egyedc, W. .
OPERATIONS RESEARCH FOR HEALTH CARE, 2014, 3 (02) :80-90