Performance study of a heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system

被引:61
|
作者
Zhang, Ning [1 ]
Yin, Shao-You [2 ]
Zhang, Li-Zhi [1 ,3 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Educ Minist, Key Lab Enhanced Heat Transfer & Energy Conservat, Guangzhou 510640, Guangdong, Peoples R China
[2] Shunde Polytech, Heat Pump Engn & Technol Dev Ctr Guangdong Univ, Foshan 528333, Peoples R China
[3] South China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
关键词
Heat pump; Hollow fiber membrane; Liquid desiccant; Two-stage; System performance; COOLING SYSTEM; MASS-TRANSFER; HVAC SYSTEMS; ENERGY; REGENERATION; OPTIMIZATION; TEMPERATURE; EXCHANGERS; SIMULATION; CHILLERS;
D O I
10.1016/j.apenergy.2016.07.037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel compression heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system is presented. The liquid desiccant droplets are prevented from crossing over into the process air by the semi-permeable membranes. The isoenthalpic processes are changed to quasi isothermal processes by the two-stage dehumidification processes. The system is set up and a model is proposed for simulation. Heat and mass capacities in the system, including the membrane modules, the condenser, the evaporator and the heat exchangers are modeled in detail. The model is also validated experimentally. Compared with a single-stage dehumidification system, the two-stage system has a lower solution concentration exiting from the dehumidifier and a lower condensing temperature. Thus, a better thermodynamic system performance is realized and the COP can be increased by about 20% under the typical hot and humid conditions in Southern China. The allocations of heat and mass transfer areas in the system are also investigated. It is found that the optimal regeneration to dehumidification area ratio is 1.33. The optimal first to second stage dehumidification area ratio is 1.4; and the optimal first to second stage regeneration area ratio is 1.286. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:727 / 737
页数:11
相关论文
共 50 条
  • [41] Performance characterization of a novel membrane-based liquid desiccant air conditioning system
    Gurubalan, A.
    Maiya, M. P.
    Tiwari, Shaligram
    INTERNATIONAL JOURNAL OF REFRIGERATION, 2020, 120 : 445 - 459
  • [42] Modeling and performance analysis of a hybrid-connected two-stage liquid dehumidification fresh air system based on CaCl2/LiCl double solution
    Peng, Donggen
    Cao, Zhuo
    APPLIED THERMAL ENGINEERING, 2021, 199
  • [43] Performance characteristics assessment of hollow fiber membrane-based liquid desiccant dehumidifier for drying application
    Tejes, P. K. S.
    Priyadarshi, Gaurav
    Naik, B. Kiran
    APPLIED THERMAL ENGINEERING, 2023, 218
  • [44] An experimental study on dehumidification and regeneration performance of a new nonporous membrane-based heat and mass exchanger using an ionic liquid desiccant
    Wang, Lingshi
    Liu, Xiaobing
    Qu, Ming
    Liu, Xiaoli
    Bahar, Bamdad
    ENERGY AND BUILDINGS, 2022, 254
  • [45] Impact of Heat Pump-Driven Liquid Desiccant Dehumidification on the Energy Performance of an Evaporative Cooling-Assisted Air Conditioning System
    Shin, Jang-Hoon
    Park, Joon-Young
    Jo, Min-Suk
    Jeong, Jae-Weon
    ENERGIES, 2018, 11 (02)
  • [46] Investigation of conjugate heat and mass transfer in a sleeve-type hollow fiber membrane for liquid desiccant dehumidification
    Zhou, Junming
    Zhao, Jinming
    Wang, Shichen
    Hu, Yuxing
    Niu, Xiaofeng
    Zhang, Kai
    Wang, Faming
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 59
  • [47] Study on LiBr-Liquid Desiccant System Driven by Heat Pump
    Wang, Zanshe
    Wang, Fang
    Peng, Junjun
    Liu, Fengrong
    Luo, Xilian
    Gu, Zhaolin
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 2068 - 2074
  • [48] Experimental and theoretical study on a heat pump driven open-air humidification dehumidification desalination system
    Lawal, Dahiru U.
    Jawad, Saad A.
    Antar, Mohamed A.
    ENERGY, 2020, 207
  • [49] Analysis of heat pump operated two-stage humidification-dehumidification desalination system with subcooler and heat regenerator
    Wang, Bingdong
    Shen, Jiubing
    Zhu, Wenting
    Wang, Wenhuan
    DESALINATION, 2024, 581
  • [50] Experimental Investigation of Solar-Driven Hollow Fiber Membrane Liquid Dehumidification System
    Liang, Cai-Hang
    Hu, Jia-Li
    Li, Nan-Feng
    He, Zhi-Peng
    Mo, Chou
    Zeng, Si
    MEMBRANES, 2023, 13 (04)