Performance study of a heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system

被引:61
|
作者
Zhang, Ning [1 ]
Yin, Shao-You [2 ]
Zhang, Li-Zhi [1 ,3 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Educ Minist, Key Lab Enhanced Heat Transfer & Energy Conservat, Guangzhou 510640, Guangdong, Peoples R China
[2] Shunde Polytech, Heat Pump Engn & Technol Dev Ctr Guangdong Univ, Foshan 528333, Peoples R China
[3] South China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
关键词
Heat pump; Hollow fiber membrane; Liquid desiccant; Two-stage; System performance; COOLING SYSTEM; MASS-TRANSFER; HVAC SYSTEMS; ENERGY; REGENERATION; OPTIMIZATION; TEMPERATURE; EXCHANGERS; SIMULATION; CHILLERS;
D O I
10.1016/j.apenergy.2016.07.037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel compression heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system is presented. The liquid desiccant droplets are prevented from crossing over into the process air by the semi-permeable membranes. The isoenthalpic processes are changed to quasi isothermal processes by the two-stage dehumidification processes. The system is set up and a model is proposed for simulation. Heat and mass capacities in the system, including the membrane modules, the condenser, the evaporator and the heat exchangers are modeled in detail. The model is also validated experimentally. Compared with a single-stage dehumidification system, the two-stage system has a lower solution concentration exiting from the dehumidifier and a lower condensing temperature. Thus, a better thermodynamic system performance is realized and the COP can be increased by about 20% under the typical hot and humid conditions in Southern China. The allocations of heat and mass transfer areas in the system are also investigated. It is found that the optimal regeneration to dehumidification area ratio is 1.33. The optimal first to second stage dehumidification area ratio is 1.4; and the optimal first to second stage regeneration area ratio is 1.286. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:727 / 737
页数:11
相关论文
共 50 条
  • [1] Investigation on capacity matching in a heat pump and hollow fiber membrane-based two-stage liquid desiccant hybrid air dehumidification system
    Zhang, Ning
    Yin, Shao-You
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2017, 84 : 128 - 138
  • [2] A heat pump driven and hollow fiber membrane-based liquid desiccant air dehumidification system: A transient performance study
    Zhang, Ning
    Zhang, Li-Zhi
    Xu, Jian-Chang
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2016, 67 : 143 - 156
  • [3] A heat pump driven and hollow fiber membrane-based liquid desiccant air dehumidification system: Modeling and experimental validation
    Zhang, Li-Zhi
    Zhang, Ning
    ENERGY, 2014, 65 : 441 - 451
  • [4] Model-based optimization for a heat pump driven and hollow fiber membrane hybrid two-stage liquid desiccant air dehumidification system
    Zhang, Ning
    Yin, Shao-You
    Li, Min
    APPLIED ENERGY, 2018, 228 : 12 - 20
  • [5] Performance Investigation of a Hollow Fiber Membrane-Based Desiccant Liquid Air Dehumidification System
    Englart, Sebastian
    Rajski, Krzysztof
    ENERGIES, 2021, 14 (11)
  • [6] Performance optimization of heat pump driven liquid desiccant dehumidification systems
    Zhang, Tao
    Liu, Xiaohua
    Jiang, Yi
    ENERGY AND BUILDINGS, 2012, 52 : 132 - 144
  • [7] Performance investigation of a counter-flow heat pump driven liquid desiccant dehumidification system
    Xie, Ying
    Zhang, Tao
    Liu, Xiaohua
    ENERGY, 2016, 115 : 446 - 457
  • [8] Performance evaluation of a heat pump-driven liquid desiccant dehumidification system integrated with fresh air supply
    Li, Wenzhang
    Yin, Yonggao
    Wang, Yikai
    ENERGY AND BUILDINGS, 2022, 275
  • [9] Triple-bore hollow fiber membrane contactor for liquid desiccant based air dehumidification
    Bettahalli, N. M. Srivatsa
    Lefers, Ryan
    Fedoroff, Nina
    Leiknes, TorOve
    Nunes, Suzana P.
    JOURNAL OF MEMBRANE SCIENCE, 2016, 514 : 135 - 142
  • [10] Performance optimization of a heat pump driven liquid desiccant dehumidification system using exergy analysis
    Zhang, Qinling
    Liu, Xiaohua
    Zhang, Tao
    Xie, Ying
    ENERGY, 2020, 204