Performance study of a heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system

被引:61
作者
Zhang, Ning [1 ]
Yin, Shao-You [2 ]
Zhang, Li-Zhi [1 ,3 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Educ Minist, Key Lab Enhanced Heat Transfer & Energy Conservat, Guangzhou 510640, Guangdong, Peoples R China
[2] Shunde Polytech, Heat Pump Engn & Technol Dev Ctr Guangdong Univ, Foshan 528333, Peoples R China
[3] South China Univ Technol, State Key Lab Subtrop Bldg Sci, Guangzhou 510640, Guangdong, Peoples R China
关键词
Heat pump; Hollow fiber membrane; Liquid desiccant; Two-stage; System performance; COOLING SYSTEM; MASS-TRANSFER; HVAC SYSTEMS; ENERGY; REGENERATION; OPTIMIZATION; TEMPERATURE; EXCHANGERS; SIMULATION; CHILLERS;
D O I
10.1016/j.apenergy.2016.07.037
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
A novel compression heat pump driven and hollow fiber membrane-based two-stage liquid desiccant air dehumidification system is presented. The liquid desiccant droplets are prevented from crossing over into the process air by the semi-permeable membranes. The isoenthalpic processes are changed to quasi isothermal processes by the two-stage dehumidification processes. The system is set up and a model is proposed for simulation. Heat and mass capacities in the system, including the membrane modules, the condenser, the evaporator and the heat exchangers are modeled in detail. The model is also validated experimentally. Compared with a single-stage dehumidification system, the two-stage system has a lower solution concentration exiting from the dehumidifier and a lower condensing temperature. Thus, a better thermodynamic system performance is realized and the COP can be increased by about 20% under the typical hot and humid conditions in Southern China. The allocations of heat and mass transfer areas in the system are also investigated. It is found that the optimal regeneration to dehumidification area ratio is 1.33. The optimal first to second stage dehumidification area ratio is 1.4; and the optimal first to second stage regeneration area ratio is 1.286. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:727 / 737
页数:11
相关论文
共 37 条
[1]   Annual evaluation of energy, environmental and economic performances of a membrane liquid desiccant air conditioning system with/without ERV [J].
Abdel-Salam, Ahmed H. ;
Simonson, Carey J. .
APPLIED ENERGY, 2014, 116 :134-148
[2]   Expected energy and economic benefits, and environmental impacts for liquid-to-air membrane energy exchangers (LAMEEs) in HVAC systems: A review [J].
Abdel-Salam, Mohamed R. H. ;
Fauchoux, Melanie ;
Ge, Gaoming ;
Besant, Robert W. ;
Simonson, Carey J. .
APPLIED ENERGY, 2014, 127 :202-218
[3]   Steady-state model of centrifugal liquid chillers [J].
Browne, MW ;
Bansal, PK .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1998, 21 (05) :343-358
[4]   Achieving better energy-efficient air conditioning - A review of technologies and strategies [J].
Chua, K. J. ;
Chou, S. K. ;
Yang, W. M. ;
Yan, J. .
APPLIED ENERGY, 2013, 104 :87-104
[5]   Performance investigation on a multi-unit heat pump for simultaneous temperature and humidity control [J].
Fan, Hongming ;
Shao, Shuangquan ;
Tian, Changqing .
APPLIED ENERGY, 2014, 113 :883-890
[6]   Steady-state simulation of screw liquid chillers [J].
Fu, L ;
Ding, GL ;
Su, ZJ ;
Zhao, GQ .
APPLIED THERMAL ENGINEERING, 2002, 22 (15) :1731-1748
[7]   Model-based optimal control of a dedicated outdoor air-chilled ceiling system using liquid desiccant and membrane-based total heat recovery [J].
Ge, Gaoming ;
Xiao, Fu ;
Xu, Xinhua .
APPLIED ENERGY, 2011, 88 (11) :4180-4190
[8]   Adsorption Equilibrium of Water on a Composite Adsorbent Employing Lithium Chloride in Silica Gel [J].
Gong, L. X. ;
Wang, R. Z. ;
Xia, Z. Z. ;
Chen, C. J. .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2010, 55 (08) :2920-2923
[9]  
Guttman I., 1965, Introductory engineering statistics
[10]  
Huan Z, 1999, BUILD SERV ENG RES T, V20, P51