Glassy carbon electrode modified by conductive polyaniline coating for determination of trace lead and cadmium ions in acetate buffer solution

被引:92
|
作者
Wang, Zhaomeng [1 ]
Liu, Erjia [1 ]
Zhao, Xing [1 ]
机构
[1] Nanyang Technol Univ, Sch Mech & Aerosp Engn, Singapore 639798, Singapore
关键词
Polyaniline modified glassy carbon electrode; Surface morphology; Square wave voltammetry; Trace lead and cadmium; ANODIC-STRIPPING VOLTAMMETRY; HEAVY-METAL IONS; FILM ELECTRODE; COMPOSITE FILM; ELECTROPOLYMERIZATION; SURFACTANTS; PB; CD;
D O I
10.1016/j.tsf.2011.01.176
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
Polyaniline (PANI) coatings were electrodeposited on the surfaces of glassy carbon electrodes (GCEs) to form new electrodes, i.e. PANI/GCEs. It was found that with increased deposition time, the PANI coatings became more compact while the charge transfer resistance of the coatings became higher. The PANI/GCEs were used to detect Cd(2+) and Pb(2+) ions contained in 0.1 M acetate buffer solutions using square wave anodic stripping voltammetry (SWASV). It was found that the PANI/GCE had a highest anodic stripping peak current in a solution of pH 5.3. The study of the cleaning performance of the PANI/GCEs indicated that there were less remaining metals on the surfaces of the PANI/GCEs compared to the bare GCEs after cleaning at a potential of 0.4 V, which was probably due to that the PANI coatings could effectively prevent the deposition of the metals into the surface defects of the GCEs. The PANI coatings could also reduce the passivation effect of the GCEs, thus improving the repeatability of the electrodes. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:5285 / 5289
页数:5
相关论文
共 50 条
  • [21] Electrochemical determination of lead using bismuth modified glassy carbon electrode
    Tufa, Lemma Teshome
    Siraj, Khalid
    Soreta, Tesfaye Refera
    RUSSIAN JOURNAL OF ELECTROCHEMISTRY, 2013, 49 (01) : 59 - 66
  • [22] Voltammetric Determination of Lead and Copper in Wine by Modified Glassy Carbon Electrode
    Antunovic, Vesna
    Tripkovic, Tatjana
    Tomasevic, Biljana
    Baosic, Rada
    Jelic, Dijana
    Lolic, Aleksandar
    ANALYTICAL SCIENCES, 2021, 37 (02) : 353 - 358
  • [23] Electrochemical determination of adenine using a glassy carbon electrode modified with graphene oxide and polyaniline
    Sharma, Vimal
    Hynek, David
    Trnkova, Libuse
    Hemzal, Dusan
    Marik, Marian
    Kizek, Rene
    Hubalek, Jaromir
    MICROCHIMICA ACTA, 2016, 183 (04) : 1299 - 1306
  • [24] A voltammetric sensor based on the glassy carbon electrode modified with multi-walled carbon nanotube/poly(pyrocatechol violet)/bismuth film for determination of cadmium and lead as environmental pollutants
    Chamjangali, M. Arab
    Kouhestani, H.
    Masdarolomoor, F.
    Daneshinejad, H.
    SENSORS AND ACTUATORS B-CHEMICAL, 2015, 216 : 384 - 393
  • [25] Poly(crystal violet)/graphene-modified electrode for the simultaneous determination of trace lead and cadmium ions in water samples
    Chen, Meifeng
    Chao, Mingyong
    Ma, Xinying
    JOURNAL OF APPLIED ELECTROCHEMISTRY, 2014, 44 (02) : 337 - 344
  • [26] Determination of trace xanthine by anodic stripping voltammetry with carbon nanotube modified glassy carbon electrode
    Zhao, G
    Zang, SQ
    Liu, KZ
    Lin, S
    Liang, J
    Guo, XY
    Zhang, ZJ
    ANALYTICAL LETTERS, 2002, 35 (14) : 2233 - 2244
  • [27] Voltammetric determination of lead and cadmium in vegetables by graphene paste electrode modified with activated carbon from coconut husk
    Palisoc, Shirley T.
    Estioko, Leonard Cedrick D.
    Natividad, Michelle T.
    MATERIALS RESEARCH EXPRESS, 2018, 5 (08):
  • [28] DETERMINATION OF TRACE OF IODIDE AT A POLY-L-METHIONINE MODIFIED GLASSY CARBON ELECTRODE
    Liu, Xu
    Gao, Hui
    Wang, Yanming
    Ma, Wei
    REVUE ROUMAINE DE CHIMIE, 2019, 64 (04) : 311 - 316
  • [29] A study of nanostructured gold modified glassy carbon electrode for the determination of trace Cr(VI)
    Liu, Benzhi
    Lu, Liyuan
    Wang, Min
    Zi, Yanqin
    JOURNAL OF CHEMICAL SCIENCES, 2008, 120 (05) : 493 - 498
  • [30] A study of nanostructured gold modified glassy carbon electrode for the determination of trace Cr(VI)
    Benzhi Liu
    Liyuan Lu
    Min Wang
    Yanqin Zi
    Journal of Chemical Sciences, 2008, 120 : 493 - 498