Characterization of ashes from a 100 kWth pilot-scale circulating fluidized bed with oxy-fuel combustion

被引:79
作者
Wu, Yinghai [1 ]
Wang, Chunbo [2 ]
Tan, Yewen [1 ]
Jia, Lufei [1 ]
Anthony, Edward J. [1 ]
机构
[1] Nat Resources Canada, CanmetENERGY, Ottawa, ON K1A 1M1, Canada
[2] N China Elect Power Univ, Sch Energy & Power Engn, Baoding, Peoples R China
关键词
Circulating fluidized bed combustion; Oxy-fuel combustion; CFBC ash; Bed ash; Fly ash; Direct sulfation; PULVERIZED COAL COMBUSTION; O-2/CO2; COMBUSTION; PARTICLE FORMATION; DIRECT SULFATION; CFB COMBUSTION; SO2; EMISSIONS; LIMESTONE; REACTIVATION; NOX; CO2;
D O I
10.1016/j.apenergy.2011.03.007
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
Oxy-fuel combustion experiments have been carried out on an oxygen-fired 100 kW(th) mini-circulating fluidized bed combustion (CFBC) facility. Coal and petroleum coke were used as fuel together with different limestones (and fixed Ca:S molar ratios) premixed with the fuel, for in situ SO2 capture. The bed ash (BA) and fly ash (FA) samples produced from this unit were collected and characterized to obtain physical and chemical properties of the ash samples. The characterization methods used included X-ray fluorescence (XRF), X-ray diffraction (XRD), char carbon and free lime analysis, thermogravimetric analysis (TGA), and surface analysis. The main purpose of this work is to characterize the CFBC ashes from oxy-fuel firing to obtain a better understanding of the combustion process, and to identify any significant differences from the ash generated by a conventional air-fired CFBC. The primary difference in the sulfur capture mechanism between atmospheric air-fired and oxy-fuel FBC, at typical FBC temperatures (similar to 850 degrees C), is that, in the air-fired case the limestone sorbents calcine, whereas the partial pressure of CO2 in oxy-fuel FBC is high enough to prevent calcination, and hence the sulfation process should mimic that seen in pressurized FBC (PFBC). Here, the char carbon content in the fly ash was much higher than that in the bed ash, and was also high by comparison with ash obtained from conventional commercial air-firing CFBC units. In addition, measurements of the free lime content in the bed and fly ash showed that the unreacted Ca sorbent was present primarily as CaCO3, indicating that sulfur capture in the oxy-fuel combustor occurred via direct sulfation. Limestone utilization for oxy-fuel combustion in this unit was generally lower than that in industrial-scale air-firing CFBCs, with better limestone performance found during combustion of petcoke running at relatively higher temperatures. The Brunauer-Emmett-Teller (BET) surface area and also the pore volume in the fly ash were much higher than in the bed ash and smaller size pores predominated in the fly ash samples. Crown Copyright (C) 2011 Published by Elsevier Ltd. All rights reserved.
引用
收藏
页码:2940 / 2948
页数:9
相关论文
共 38 条
[1]  
*ALSTOM POW INC, 2004, GREENH GAS EM CONTR
[2]  
[Anonymous], 35 INT TECHN C CLEAN
[3]  
[Anonymous], 35 INT TECHN C CLEAN
[4]   Advanced ash management technologies for CFBC ash [J].
Anthony, EJ ;
Berry, EE ;
Blondin, J ;
Bulewicz, EM ;
Burwell, S .
WASTE MANAGEMENT, 2003, 23 (06) :503-516
[5]   An examination of the exothermic nature of fluidized bed combustion (FBC) residues [J].
Anthony, EJ ;
Jia, L ;
Caris, M ;
Preto, F ;
Burwell, S .
WASTE MANAGEMENT, 1999, 19 (04) :293-305
[6]  
ANTHONY EJ, 1995, PRESSURIZED FLUIDIZE, P106
[7]   Oxy-fuel combustion technology for coal-fired power generation [J].
Buhre, BJP ;
Elliott, LK ;
Sheng, CD ;
Gupta, RP ;
Wall, TF .
PROGRESS IN ENERGY AND COMBUSTION SCIENCE, 2005, 31 (04) :283-307
[8]   NOx and SO2 emissions from O2/CO2 recycle coal combustion [J].
Croiset, E ;
Thambimuthu, KV .
FUEL, 2001, 80 (14) :2117-2121
[9]   Oxy-fuel circulating fluidized bed combustion in a small pilot-scale test rig [J].
Czakiert, T. ;
Sztekler, K. ;
Karski, S. ;
Markiewicz, D. ;
Nowak, W. .
FUEL PROCESSING TECHNOLOGY, 2010, 91 (11) :1617-1623
[10]  
Eriksson T., 2009, POW GEN EUR COL GERM