Point-of-care ultrasonography-assisted nasogastric tube placement in the emergency department: a randomized controlled trial

被引:3
|
作者
Yaseen, Mohd [1 ]
Kumar, Akshay [1 ]
Bhoi, Sanjeev [1 ]
Sinha, Tej Prakash [1 ]
Jamshed, Nayer [1 ]
Aggarwal, Praveen [1 ]
Murmu, Lakhi Ram [1 ]
Ekka, Meera [1 ]
机构
[1] All India Inst Med Sci, Dept Emergency Med, New Delhi 110029, India
关键词
emergency department; nasogastric tube insertion; POCUS; ultrasonography; ULTRASOUND; INSERTION;
D O I
10.1097/MEJ.0000000000000962
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background The complications of a blind procedure for gastric tube placement are well documented. POCUS has been widely used to confirm the position of blindly inserted gastric tubes, and it does not prevent complications caused by the blind method. We performed a randomized controlled trial to compare gastric tube insertion with real-time oesophagus visualization using POCUS to the standard technique. Objective The primary goal of this study was to compare the accuracy of real-time POCUS-guided nasogastric tube (NGT) insertion and confirmation to that of the standard technique. Methods It was a prospective, parallel-group, open-label randomized controlled trial with a superiority design. All patients requiring NGT were screened for inclusion and exclusion criteria, and 120 patients were randomly assigned to one of two groups: POCUS (n = 60) or control (n = 60). Following the procedures, confirmatory chest radiographs were obtained in both groups. Results As per protocol, 118 patients were analyzed. In POCUS group, the oesophagus was visualized on POCUS in 56 of 58 patients (96.5%). In 55 of 58 cases (94.8%), an NGT was inserted in real time. Despite visualizing the oesophagus, we fail to insert the tube in one (1.8%). The oesophagus could not be seen on the scan in two cases (3.4%). Chest radiographs confirmed the tube in the stomach in 55 (98.2%). The chest radiograph revealed the tip of the NGT in the stomach in 52 of 60 (86.6%) patients. In seven cases (11.7%), we were unable to insert NGT. On a chest radiograph, one (1.6%) tip of the tube was seen in the right lung and was safely removed. The ultrasound-guided gastric tube insertion had a sensitivity of 96.5% (95% CI, 88-99.6%) and a positive predictive value (PPV) of 98.2% (95% CI, 98.1-98.3%). The conventional technique had 88% (95% CI, 77-95%) sensitivity and a PPV of 98% (95% CI, 97.9-98.2%). Conclusion POCUS enables real-time insertion of a gastric tube with high sensitivity, in a short time with high first-attempt success rate and limited passage-related complications. POCUS should be utilized for NGT insertion whenever expertise is available on the bedside.
引用
收藏
页码:431 / 436
页数:6
相关论文
共 50 条
  • [31] Point-of-care ultrasound for confirmation of gastrostomy tube replacement in the pediatric emergency department
    Alerhand, Stephen
    Tay, Ee Tein
    INTERNAL AND EMERGENCY MEDICINE, 2020, 15 (06) : 1075 - 1079
  • [32] Point of care ultrasonography in the pediatric emergency department
    Le Coz, Julien
    Orlandini, Silvia
    Titomanlio, Luigi
    Rinaldi, Victoria Elisa
    ITALIAN JOURNAL OF PEDIATRICS, 2018, 44
  • [33] Point-of-care ultrasound for confirmation of gastrostomy tube replacement in the pediatric emergency department
    Stephen Alerhand
    Ee Tein Tay
    Internal and Emergency Medicine, 2020, 15 : 1075 - 1079
  • [34] Point of care ultrasonography in the pediatric emergency department
    Julien Le Coz
    Silvia Orlandini
    Luigi Titomanlio
    Victoria Elisa Rinaldi
    Italian Journal of Pediatrics, 44
  • [35] Transfer from point-of-care Ultrasonography training to diagnostic performance on patients-a randomized controlled trial
    Todsen, Tobias
    Jensen, Morten Lind
    Tolsgaard, Martin Gronnebaek
    Olsen, Beth Harstedt
    Henriksen, Birthe Merete
    Hillingso, Jens Georg
    Konge, Lars
    Ringsted, Charlotte
    AMERICAN JOURNAL OF SURGERY, 2016, 211 (01): : 40 - 45
  • [36] A randomized trial to assess the efficacy of point-of-care testing in decreasing length of stay in a pediatric emergency department
    Hsiao, Allen L.
    Santucci, Karen A.
    Dziura, James
    Baker, M. Douglas
    PEDIATRIC EMERGENCY CARE, 2007, 23 (07) : 457 - 462
  • [37] Hemodynamic Instability in Emergency Department: Giant Rectus Sheath Hematoma and Point-of-Care Ultrasonography
    Ay, Yagmur
    Canakci, Mustafa Emin
    Temel, Tuncer
    Ozakin, Engin
    Acar, Nurdan
    CUREUS JOURNAL OF MEDICAL SCIENCE, 2021, 13 (03)
  • [38] EMBOLIC CENTRAL RETINAL ARTERY OCCLUSION DETECTED WITH POINT-OF-CARE ULTRASONOGRAPHY IN THE EMERGENCY DEPARTMENT
    Riccardi, Alessandro
    Siniscalchi, Cristina
    Lerza, Roberto
    JOURNAL OF EMERGENCY MEDICINE, 2016, 50 (04): : E183 - E185
  • [39] Traumatic Femoral Artery Thrombosis Diagnosed by Point-of-Care Ultrasonography in the Pediatric Emergency Department
    Jones, Sarah D.
    Fischer, Jason
    Kwan, Charisse
    Tessaro, Mark
    PEDIATRIC EMERGENCY CARE, 2016, 32 (12) : 885 - 887
  • [40] Point-of-care testing improves care timeliness in the emergency department. A multicenter randomized clinical trial (study POCTUR)
    Leon-Justel, Antonio
    Bustos, Carmen Navarro
    Noval-Padillo, Jose Angel
    Perez, Salomon Martin
    Gomez, Maria Dolores Aviles
    Valencia, Nelia Jimenez
    Castilla, Jose M. Garrido
    Munoz, Miguel Diaz
    Vizcaino, Maria A. Rivera
    Heredia, Laura Alvarez
    Moreno, Emilia Gracia
    Fontan, Maria Esther Roldan
    Mariscal, Caludio Bueno
    Montavez, Juan Miguel Guerrero
    Sanchez-Mora, Catalina
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2024,