Adjustable Thermoplastic Oral Appliance Versus Positive Airway Pressure for Obstructive Sleep Apnea

被引:13
作者
Banhiran, Wish [1 ,2 ]
Assanasen, Paraya [1 ]
Nopmaneejumrudlers, Cherdchai [3 ]
Nujchanart, Nongyoaw [4 ]
Srechareon, Wimontip [4 ]
Chongkolwatana, Cheerasook [1 ]
Metheetrairut, Choakchai [1 ]
机构
[1] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Otorhinolaryngol, Bangkok 10700, Thailand
[2] Mahidol Univ, Siriraj Hosp, Fac Med, Siriraj Sleep Ctr, Bangkok, Thailand
[3] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Med, Bangkok, Thailand
[4] Mahidol Univ, Siriraj Hosp, Fac Med, Dept Nursing, Bangkok, Thailand
关键词
Obstructive sleep apnea; quality of life; thermoplastic; mandibular advancement splint; Somnoguard; oral appliances; boil and bite; Asian; Thai; MANDIBULAR ADVANCEMENT DEVICES; QUALITY-OF-LIFE; RANDOMIZED CROSSOVER; THAI PATIENTS; OUTCOMES; METAANALYSIS; EFFICACY; HEALTH; TRIAL; GUIDELINE;
D O I
10.1002/lary.26753
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Objectives/Hypothesis: To compare outcomes of continuous positive airway pressure (CPAP) and the adjustable thermoplastic mandibular advancement splint (AT-MAS) for obstructive sleep apnea treatment. Study Design: Randomized crossover, noninferiority, tertiary center setting. Methods: Fifty patients with a mean age of 49.5 +/- 10.6 years were enrolled. Inclusion criteria were age >= 18 years, apnea-hypopnea index (AHI) >= 5 events/hour, and oxygen saturation >= 70%. Exclusion criteria were temporomandibular joint disorders, severe periodontitis, inadequate teeth, and unstable medical diseases. Treatment intolerance was considered a failure. Two-week periods without treatment were followed by questionnaires and randomization into two groups: CPAP/AT-MAS (25) and AT-MAS/CPAP (25). After 6 weeks of intervention, questionnaires and home WatchPAT monitoring were performed. Following each 2-week washout period, patients crossed over to the other treatment followed by similar procedures. Primary outcomes involved the scores from the Functional Outcomes of Sleep Questionnaire (FOSQ). Secondary outcomes were AHI, side effects, and treatment adherence. Results: Seven patients withdrew from this study: five (AT-MAS intolerance) and two (lost follow-up). There was no significant difference among FOSQ scores, particularly on global scores, between both treatments (0.57, 95% confidential interval of difference: -0.15 to 1.29). Mean AHI decreased from pretreatment 39.2 +/- 2.53 to 2.56 +/- 0.49 and 12.92 +/- 2.05 events/hour while using CPAP and the AT-MAS, respectively (P < .05). Most common side effects of CPAP were dry throat and inconvenience to carry, whereas those of the AT-MAS were jaw pain and excessive salivation. Conclusions: Both devices improved short-term quality of life similarly; however, the AT-MAS was not as efficacious as CPAP on resolving sleep-test parameters. The AT-MAS might be considered only a temporary treatment alternative.
引用
收藏
页码:516 / 522
页数:7
相关论文
共 30 条
[1]   Oral Appliance Therapy versus Nasal Continuous Positive Airway Pressure in Obstructive Sleep Apnea: A Randomized, Placebo-Controlled Trial [J].
Aarab, Ghizlane ;
Lobbezoo, Frank ;
Hamburger, Hans L. ;
Naeije, Machiel .
RESPIRATION, 2011, 81 (05) :411-419
[2]   The association of sleep-disordered breathing and sleep symptoms with quality of life in the sleep heart health study [J].
Baldwin, CM ;
Griffith, KA ;
Nieto, FJ ;
O'Connor, GT ;
Walsleben, JA ;
Redline, S .
SLEEP, 2001, 24 (01) :96-105
[3]   Adjustable Thermoplastic Mandibular Advancement Device for Obstructive Sleep Apnea: Outcomes and Practicability [J].
Banhiran, Wish ;
Kittiphumwong, Phantipar ;
Assanasen, Paraya ;
Chongkolwatana, Cheerasook ;
Metheetrairut, Choakchai .
LARYNGOSCOPE, 2014, 124 (10) :2427-2432
[4]  
Banhiran Wish, 2013, Journal of the Medical Association of Thailand, V96, P209
[5]   Functional outcomes of sleep in Thai patients with obstructive sleep-disordered breathing [J].
Banhiran, Wish ;
Assanasen, Paraya ;
Metheetrairut, Choakchai ;
Nopmaneejumruslers, Cherdchai ;
Chotinaiwattarakul, Wattanachai ;
Kerdnoppakhun, Jeerapa .
SLEEP AND BREATHING, 2012, 16 (03) :663-675
[6]   Epworth sleepiness scale in obstructive sleep disordered breathing: the reliability and validity of the Thai version [J].
Banhiran, Wish ;
Assanasen, Paraya ;
Nopmaneejumruslers, Cherdchai ;
Metheetrairut, Choakchai .
SLEEP AND BREATHING, 2011, 15 (03) :571-577
[7]   Efficacy of positive airway pressure and oral appliance in mild to moderate obstructive sleep apnea [J].
Barnes, M ;
McEvoy, RD ;
Banks, S ;
Tarquinio, N ;
Murray, CG ;
Vowles, N ;
Pierce, RJ .
AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2004, 170 (06) :656-664
[8]   Determinants of Objective Compliance During Oral Appliance Therapy in Patients With Sleep-Disordered Breathing A Prospective Clinical Trial [J].
Dieltjens, Marijke ;
Verbruggen, Annelies E. ;
Braem, Marc J. ;
Wouters, Kristien ;
Verbraecken, Johan A. ;
De Backer, Wilfried A. ;
Hamans, Evert ;
Van de Heyning, Paul H. ;
Vanderveken, Olivier M. .
JAMA OTOLARYNGOLOGY-HEAD & NECK SURGERY, 2015, 141 (10) :894-900
[9]   Oral Appliance Versus Continuous Positive Airway Pressure in Obstructive Sleep Apnea Syndrome: A 2-Year Follow-up [J].
Doff, Michiel H. J. ;
Hoekema, Aarnoud ;
Wijkstra, Peter J. ;
van der Hoeven, Johannes H. ;
Slater, James J. R. Huddleston ;
de Bont, Lambert G. M. ;
Stegenga, Boudewijn .
SLEEP, 2013, 36 (09) :1289-1296
[10]   Obstructive sleep apnea and cardiovascular risk: Meta-analysis of prospective cohort studies [J].
Dong, Jia-Yi ;
Zhang, Yong-Hong ;
Qin, Li-Qiang .
ATHEROSCLEROSIS, 2013, 229 (02) :489-495