Synthesis, thermoluminescence, defect centers and dosimetric characteristics of LiF:Mg,Cu,B phosphor

被引:3
作者
Preto, Prince David [1 ]
Balraj, Vidyavathy [1 ]
Dhabekar, Bhushan S. [2 ]
Watanabe, S. [3 ]
Rao, T. K. Gundu [3 ]
机构
[1] Velammal Engn Coll, Dept Chem, Solid State Chem Res Lab, Chennai 600066, Tamil Nadu, India
[2] Bhabha Atom Res Ctr, Radiol Phys & Advisory Div, Mumbai 400085, Maharashtra, India
[3] Univ Sao Paulo, Inst Phys, BR-05508090 Sao Paulo, SP, Brazil
关键词
Thermoluminescence phosphor; Dose response; Thermoluminescence emission; Solid state reaction; Electron spin resonance; Defect centers; ELECTRON-SPIN-RESONANCE; F-CENTERS; COPPER IMPURITY; ALKALI-HALIDES; LIF-MG; CU; P; LIF; EMISSION; LIFCU; MG; RADIATION; CRYSTALS;
D O I
10.1016/j.apradiso.2016.08.015
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
The present paper reports the thermoluminescence (TL), dosimetric characteristics and electron spin resonance (ESR) of LiF: Mg, Cu,B (MCB) phosphor synthesized by a solid state method. Its glow curve structure is similar to that of LiF: Mg, Cu,P (MCP) phosphor with the main dosimetric peak at 218 degrees C. MCB is 12 times more sensitive than LiF: Mg, Ti and about 1.9 times less sensitive than MCP phosphor. A noteworthy feature is that the, phosphor exhibits a linear dose response up to 100 Gy with a minimum detectable dose of 17 mu Gy. The TL emission spectrum was recorded and the post irradiation fading in MCB at ambient temperatures and humidity was negligible for a period of one month. Room temperature ESR spectrum of irradiated phosphor consists of at least two distinct centers. Center I with an isotropic g factor 2.0061 is attributable to an F-center and is the likely recombination center for the main TL peak at 220 degrees C. Center II characterized by a g-factor 2.0090 and an unusual broad line (linewidth similar to 415 G) is also identified as an F-center. A third defect center, observable during thermal annealing at high temperature, is assigned to another F-center. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:95 / 101
页数:7
相关论文
共 35 条
[1]  
BACCI C, 1993, RADIAT PROT DOSIM, V47, P215
[2]   Comparison of LiF:Mg,Cu,P (MCP-N, GR-200A) and alpha-Al2O3:C TL detectors in short-term measurements of natural radiation [J].
Budzanowski, M ;
Bilski, P ;
BotterJensen, L ;
Delgado, A ;
Olko, P ;
SaezVergara, JC ;
Waligorski, MPR .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :157-160
[3]   Thermoluminescence of LiF:Mg,Cu,P (GR-200A) TLD after annealing between 200 and 400 degrees C [J].
Cai, GG ;
Fesquet, J ;
Dusseau, L ;
Martini, M ;
Meinardi, F ;
Huang, BL ;
Tang, KY ;
Beteille, D ;
Gasiot, J .
RADIATION PROTECTION DOSIMETRY, 1996, 65 (1-4) :163-166
[4]   Role of copper in LiF:Mg,Cu,P thermoluminescent phosphors [J].
Chen, TC ;
Stoebe, TG .
RADIATION PROTECTION DOSIMETRY, 1998, 78 (02) :101-106
[5]   Contribution of Paramagnetic Surface F+ and Ti3+ Centers to Ferromagnetism in Pure and Defective TiO2 Nanoparticles [J].
Choudhury, Biswajit ;
Choudhury, Amarjyoti .
SCIENCE OF ADVANCED MATERIALS, 2014, 6 (10) :2115-2123
[6]   Recent improvements in LiF:Mg,Ti and LiF:Mg,Cu,P based environmental dosimetry [J].
Delgado, A .
RADIATION PROTECTION DOSIMETRY, 1996, 66 (1-4) :129-134
[7]  
Doh S. H., 1989, KOREAN APPL PHYS, V2, P425
[8]   Dose linearity of LiF:Mg,Ti and LiF:Mg,Cu,P in radiotherapy:: Effect of time between dose and evaluation [J].
Duggan, L ;
Kron, T .
RADIATION PROTECTION DOSIMETRY, 1999, 85 (1-4) :397-400
[9]   ESR study of phosphorus-related defects in irradiated LiF:Mg,Cu,P and related phosphors [J].
Gundurao, T. K. ;
Moharil, S. V. .
RADIATION MEASUREMENTS, 2007, 42 (01) :35-42
[10]   Radiation-induced defects in LiAlO2 crystals: Holes trapped by lithium vacancies and their role in thermoluminescence [J].
Holston, M. S. ;
McClory, J. W. ;
Giles, N. C. ;
Halliburton, L. E. .
JOURNAL OF LUMINESCENCE, 2015, 160 :43-49