Non-invasive hemoglobin measurement using embedded platform

被引:16
|
作者
Pinto, Caje [1 ]
Parab, Jivan [1 ]
Naik, Gourish [1 ]
机构
[1] Goa Univ, Dept Elect, Taleigao 403206, Goa, India
关键词
Anemia; Embedded; Hemoglobin; Photoplethysmography; Signal conditioning;
D O I
10.1016/j.sbsr.2020.100370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper is based on the design and development of an in-house algorithm system to Estimate Total Hemoglobin in human blood using the Arduino based Embedded system. In our present society, monitoring Hemoglobin of subjects is very important in hospitals to keep track of low/high hemoglobin count during operations, delivery, dialysis, blood donations, perform stress test, monitoring patients in intensive care units, etc. is often done using invasive methods. In our approach, we have designed a finger probe using five LEDs on a multi-chip having wavelengths 670 nm/770 nm/810 nm/850 nm and 950 nm, and a single silicon photo detector with an inbuilt trans-impedance amplifier to acquire the signals through the finger using the Photoplethysmography (PPG) principle. The non-invasive method can be replaced in hospitals and homes to monitor the total hemoglobin level which is in real-time, painless, and infection-free from needles. We have tested our system on 8 subjects for three and five wavelengths and the values were compared to the hemoglobin measured using invasive methods in the pathology laboratory. The result demonstrates that the five wavelengths PPG method significantly improves the measurement accuracy of total hemoglobin, reducing the mean absolute error between the reference and the estimated hemoglobin values from 1.3778 g/dL for three wavelengths PPG to 0.3499 g/dL for five wavelengths PPG. The five wavelengths PPG system designed showed good linearity to estimate hemoglobin with the Regression Coefficient (R-2 = 0.964) compared to three wavelengths PPG system with the Regression Coefficient (R-2 = 0.688).
引用
收藏
页数:6
相关论文
共 50 条
  • [41] Photoplethysmography for non-invasive in vivo measurement of bone hemodynamics
    Mateus, Jaime
    Hargens, Alan R.
    PHYSIOLOGICAL MEASUREMENT, 2012, 33 (06) : 1027 - 1042
  • [42] Can Non-Invasive Spectrophotometric Hemoglobin Replace Laboratory Hemoglobin Concentrations for Preoperative Anemia Screening? A Diagnostic Test Accuracy Study
    Alwabari, Maryam
    Alhamad, Fatimah
    Alsahaf, Fatimah
    Al Amer, Fatima
    Alniniya, Fatma
    Alherz, Imran
    Omer, Nawal
    Bushehab, Abdulaziz
    Yassen, Khaled
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (17)
  • [43] Correlation of Blood Hemoglobin Values with Non-Invasive Co-Oximetry Measurement of SpHb in Dogs Undergoing Elective Ovariohysterectomy
    Espinosa-Morales, Maria Fernanda
    Miranda-Cortes, Agatha Elisa
    Mota-Rojas, Daniel
    Casas-Alvarado, Alejandro
    Jimenez-Yedra, Alejandro
    Perez-Sanchez, Alicia Pamela
    Hernandez-Avalos, Ismael
    ANIMALS, 2024, 14 (06):
  • [44] Evaluation of Non-Invasive Hemoglobin Monitoring in Perioperative Patients: A Retrospective Study of the Rad-67™ (Masimo)
    Helmer, Philipp
    Steinisch, Andreas
    Hottenrott, Sebastian
    Schlesinger, Tobias
    Sammeth, Michael
    Meybohm, Patrick
    Kranke, Peter
    DIAGNOSTICS, 2025, 15 (02)
  • [45] NIR-based Sensing System for Non-invasive Detection of Hemoglobin for Point-of-care Applications
    Kumar, Yogesh
    Dogra, Ayush
    Shaw, Vikash
    Kaushik, Ajeet
    Kumar, Sanjeev
    CURRENT MEDICAL IMAGING, 2022, 18 (05) : 532 - 545
  • [46] Noninvasive or invasive hemoglobin measurement?
    Lacroix, Jacques
    Tucci, Marisa
    CRITICAL CARE MEDICINE, 2012, 40 (09) : 2715 - 2716
  • [47] Non-invasive monitoring using photoplethysmography technology
    Tomita, Keisuke
    Nakada, Taka-aki
    Oshima, Taku
    Oami, Takehiko
    Aizimu, Tuerxun
    Oda, Shigeto
    JOURNAL OF CLINICAL MONITORING AND COMPUTING, 2019, 33 (04) : 637 - 645
  • [48] Non-invasive monitoring using photoplethysmography technology
    Keisuke Tomita
    Taka-aki Nakada
    Taku Oshima
    Takehiko Oami
    Tuerxun Aizimu
    Shigeto Oda
    Journal of Clinical Monitoring and Computing, 2019, 33 : 637 - 645
  • [49] Sensor fusion for the accurate non-invasive measurement of blood pressure
    Nagy P.
    Jobbágy Á.
    Measurement: Sensors, 2022, 24
  • [50] Non-invasive measurement of blood and tissue parameters based on VIS-NIR spectroscopy
    Kraitl, Jens
    Timm, Ulrich
    Ewald, Hartmut
    OPTICAL DIAGNOSTICS AND SENSING XIII: TOWARD POINT-OF-CARE DIAGNOSTICS, 2013, 8591