Non-invasive hemoglobin measurement using embedded platform

被引:16
|
作者
Pinto, Caje [1 ]
Parab, Jivan [1 ]
Naik, Gourish [1 ]
机构
[1] Goa Univ, Dept Elect, Taleigao 403206, Goa, India
关键词
Anemia; Embedded; Hemoglobin; Photoplethysmography; Signal conditioning;
D O I
10.1016/j.sbsr.2020.100370
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
This paper is based on the design and development of an in-house algorithm system to Estimate Total Hemoglobin in human blood using the Arduino based Embedded system. In our present society, monitoring Hemoglobin of subjects is very important in hospitals to keep track of low/high hemoglobin count during operations, delivery, dialysis, blood donations, perform stress test, monitoring patients in intensive care units, etc. is often done using invasive methods. In our approach, we have designed a finger probe using five LEDs on a multi-chip having wavelengths 670 nm/770 nm/810 nm/850 nm and 950 nm, and a single silicon photo detector with an inbuilt trans-impedance amplifier to acquire the signals through the finger using the Photoplethysmography (PPG) principle. The non-invasive method can be replaced in hospitals and homes to monitor the total hemoglobin level which is in real-time, painless, and infection-free from needles. We have tested our system on 8 subjects for three and five wavelengths and the values were compared to the hemoglobin measured using invasive methods in the pathology laboratory. The result demonstrates that the five wavelengths PPG method significantly improves the measurement accuracy of total hemoglobin, reducing the mean absolute error between the reference and the estimated hemoglobin values from 1.3778 g/dL for three wavelengths PPG to 0.3499 g/dL for five wavelengths PPG. The five wavelengths PPG system designed showed good linearity to estimate hemoglobin with the Regression Coefficient (R-2 = 0.964) compared to three wavelengths PPG system with the Regression Coefficient (R-2 = 0.688).
引用
收藏
页数:6
相关论文
共 50 条
  • [31] Non-Invasive Estimation of Hemoglobin Using a Multi-Model Stacking Regressor
    Acharya, Soumyadipta
    Swaminathan, Dhivya
    Das, Sreetama
    Kansara, Krity
    Chakraborty, Sushovan
    Kumar, Dinesh R.
    Francis, Tony
    Aatre, Kiran R.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2020, 24 (06) : 1717 - 1726
  • [32] Non-invasive hemoglobin estimation from conjunctival images using deep learning
    Cuvadar, Beyza
    Yilmaz, Hakan
    MEDICAL ENGINEERING & PHYSICS, 2023, 120
  • [33] Influence of hemoglobin on non-invasive optical bilirubin sensing
    Jiang, Jingying
    Gong, Qiliang
    Zou, Da
    Xu, Kexin
    DYNAMICS AND FLUCTUATIONS IN BIOMEDICAL PHOTONICS IX, 2012, 8222
  • [34] Non-Invasive Blood Pressure Measurement Using A Mobile Phone Camera
    Zhang, Yuxuan
    Zhang, Xiao
    Du, Jinlian
    2022 IEEE CONFERENCE ON COMPUTATIONAL INTELLIGENCE IN BIOINFORMATICS AND COMPUTATIONAL BIOLOGY (IEEE CIBCB 2022), 2022, : 11 - 16
  • [35] Non-invasive in-vivo monitoring of total blood hemoglobin
    Wuori, ER
    Gmitter, MB
    OPTICAL DIAGNOSTICS AND SENSING IN BIOMEDICINE III, 2003, 4965 : 160 - 167
  • [36] Support Vector Regression for Non-invasive Detection of Human Hemoglobin
    Yuan Jing-Ze
    Lu Qi-Peng
    Wang Jing-Li
    Ding Hai-Quan
    Gao Hong-Zhi
    Wu Chun-Yang
    Li Wan-Xia
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2017, 45 (09) : 1291 - 1296
  • [37] A Non-Invasive Hemoglobin Detection Device Based on Multispectral Photoplethysmography
    Zhu, Jianming
    Sun, Ruiyang
    Liu, Huiling
    Wang, Tianjiao
    Cai, Lijuan
    Chen, Zhencheng
    Heng, Baoli
    BIOSENSORS-BASEL, 2024, 14 (01):
  • [38] Continuous non-invasive hemoglobin monitoring in pediatric trauma setting
    Romanelli, Antonio
    De Rosa, Rosanna Carmela
    WORLD JOURNAL OF PEDIATRIC SURGERY, 2023, 6 (04)
  • [39] Non-Invasive Blood Components Measurement Using Optical Sensor System Interface
    Raikham, Pamshangphy
    Kumar, Rohit
    Shah, Rahul Kumar
    Hazarika, Mery
    Sonkar, R. K.
    2018 3RD INTERNATIONAL CONFERENCE ON MICROWAVE AND PHOTONICS (ICMAP), 2018,
  • [40] The Comparison of Hemoglobin Values Measured by Blood and Continuous Non-Invasive Monitoring (SpHb) in Newborn Infants
    Kazanasmaz, Halil
    Demir, Mahmut
    JOURNAL OF TROPICAL PEDIATRICS, 2021, 67 (03)