Solid contact ion sensor with conducting polymer layer copolymerized with the ion-selective membrane for determination of calcium in blood serum

被引:28
作者
Abramova, Natalia [1 ,2 ]
Moral-Vico, Javier [3 ]
Soley, Jordi [1 ]
Ocana, Cristina [1 ]
Bratov, Andrey [1 ]
机构
[1] CSIC, BioMEMS Grp, Inst Microelect Barcelona, Ctr Nacl Microelect, Campus UAB, Barcelona 08193, Spain
[2] ITMO Univ, Lab Artificial Sensors Syst, Kronverskiy Pr 49, St Petersburg 197101, Russia
[3] Univ Autonoma Barcelona, Dept Chem Biol & Environm Engn, Escola Engn, E-08193 Barcelona, Spain
基金
欧盟第七框架计划;
关键词
Solid-contact ion selective electrode; Conducting polymer; Calcium ions; Blood serum; FIELD-EFFECT TRANSISTORS; ATTENUATED TOTAL-REFLECTION; WATER-UPTAKE; POLY(VINYL CHLORIDE); ELECTRODES; POLYANILINE; FILMS;
D O I
10.1016/j.aca.2016.09.017
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A new solid contact ion selective electrode with intermediate conducting polymer (CP) layer formed by electropolymerization on a gold electrode of a bifunctional monomer, n-phenyl-ethylenediamine-methacrylamide (NPEDMA), which contains a methacrylamide group attached to aniline, is presented. The conducting polymer was studied by means of optical spectroscopy, cyclic voltammetry and potentiometric measurements. Ca2+ -ion-selective membrane based on acrylated urethane polymer was shown to co-polymerize with the CP forming highly adhesive boundary that prevents formation of water layers between the CP and membrane, thus enhancing the stability and life-time of the sensor. The designed ion-selective electrode was successfully used for determination of total calcium ion concentration in blood serum samples. (C) 2016 Elsevier B.V. All rights reserved.
引用
收藏
页码:50 / 57
页数:8
相关论文
共 36 条
[1]   New flow-through analytical system based on ion-selective field effect transistors with optimised calcium selective photocurable membrane for bovine serum analysis [J].
Abramova, N. ;
Bratov, A. ;
Ipatov, A. ;
Levichev, S. ;
Aris, A. ;
Rodriguez, E. M. .
TALANTA, 2013, 113 :31-35
[2]   The influence of CO2 on ISFETs with polymer membranes and characterization of a carbonate ion sensor [J].
Abramova, Natalia ;
Levichev, Sergey ;
Bratov, Andrey .
TALANTA, 2010, 81 (4-5) :1750-1754
[3]   Photocurable Polymers for Ion Selective Field Effect Transistors. 20 Years of Applications [J].
Abramova, Natalia ;
Bratov, Andrei .
SENSORS, 2009, 9 (09) :7097-7110
[4]   NEUTRAL CARRIER BASED ION-SELECTIVE ELECTRODE FOR THE DETERMINATION OF TOTAL CALCIUM IN BLOOD-SERUM [J].
ANKER, P ;
WIELAND, E ;
AMMANN, D ;
DOHNER, RE ;
ASPER, R ;
SIMON, W .
ANALYTICAL CHEMISTRY, 1981, 53 (13) :1970-1974
[5]  
[Anonymous], 1985, The Aldrich Library of FT-IR Spectra
[6]   Conducting polymer-based solid-state ion-selective electrodes [J].
Bobacka, J .
ELECTROANALYSIS, 2006, 18 (01) :7-18
[7]   Potentiometric ion sensors based on conducting polymers [J].
Bobacka, J ;
Ivaska, A ;
Lewenstam, A .
ELECTROANALYSIS, 2003, 15 (5-6) :366-374
[8]   Potentiometric ion sensors [J].
Bobacka, Johan ;
Ivaska, Ari ;
Lewenstam, Andrzej .
CHEMICAL REVIEWS, 2008, 108 (02) :329-351
[9]   Ion-selective field effect transistor (ISFET)-based calcium ion sensor with photocured polyurethane membrane suitable for ionised calcium determination in milk [J].
Bratov, A ;
Abramova, N ;
Domínguez, C ;
Baldi, A .
ANALYTICA CHIMICA ACTA, 2000, 408 (1-2) :57-64
[10]   Recent trends in potentiometric sensor arrays-A review [J].
Bratov, A. ;
Abramova, N. ;
Ipatov, A. .
ANALYTICA CHIMICA ACTA, 2010, 678 (02) :149-159