Optimal geometric arrangement of staggered plates in forced convection

被引:39
作者
Fowler, AJ
Ledezma, GA
Bejan, A
机构
[1] DUKE UNIV,DEPT MECH ENGN & MAT SCI,DURHAM,NC 27708
[2] UNIV MASSACHUSETTS,DEPT MECH ENGN,N DARTMOUTH,MA 02747
关键词
D O I
10.1016/S0017-9310(96)00251-7
中图分类号
O414.1 [热力学];
学科分类号
摘要
This paper reports the results of an experimental and numerical study of the optimal geometric arrangement of staggered parallel plates in a fixed volume with forced convection heat transfer. The objective of the geometric optimization effort is to maximize the total heat transfer rate between the given volume and the given external flow, when the maximum temperature at a point inside the volume cannot exceed a certain level. The geometric arrangement was varied systematically, by changing the spacing between plates, the number of plates installed in one row, the plate swept length, and the degree to which the plates are staggered. In the first part of the study, it is demonstrated experimentally that there exists an optimal spacing between two adjacent row of plates. Experimental results are reported for air in the range 1000 less than or equal to Re-L less than or equal to 6000, where L is the swept length of the fixed volume. In the second part of the study, extensive numerical results support and extend these findings to 100 less than or equal to Re-L less than or equal to 10 000. In addition, it is shown that there is an optimal way to stagger the plates. In the concluding part of the paper, the optimal spacing and maximum heat transfer rate results are correlated based on the theoretical method of intersecting the two asymptotes (small spacing, large spacing) of the geometric arrangement. (C) 1997 Elsevier Science Ltd.
引用
收藏
页码:1795 / 1805
页数:11
相关论文
共 27 条
[1]   THE EFFECT OF PLATE SPACING ON FREE-CONVECTION BETWEEN HEATED PARALLEL PLATES [J].
ANAND, NK ;
KIM, SH ;
FLETCHER, LS .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1992, 114 (02) :515-518
[2]   THERMALLY OPTIMUM SPACING OF VERTICAL, NATURAL-CONVECTION COOLED, PARALLEL PLATES [J].
BARCOHEN, A ;
ROHSENOW, WM .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1984, 106 (01) :116-123
[3]   THE OPTIMAL SPACING FOR CYLINDERS IN CROSS-FLOW FORCED-CONVECTION [J].
BEJAN, A .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 1995, 117 (03) :767-770
[4]   THE OPTIMAL SPACING OF A STACK OF PLATES COOLED BY TURBULENT FORCED-CONVECTION [J].
BEJAN, A ;
MOREGA, AM .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1994, 37 (06) :1045-1048
[5]   THE OPTIMAL SPACING OF PARALLEL PLATES COOLED BY FORCED-CONVECTION [J].
BEJAN, A ;
SCIUBBA, E .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1992, 35 (12) :3259-3264
[6]   THE OPTIMAL SPACING BETWEEN HORIZONTAL CYLINDERS IN A FIXED VOLUME COOLED BY NATURAL-CONVECTION [J].
BEJAN, A ;
FOWLER, AJ ;
STANESCU, G .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 1995, 38 (11) :2047-2055
[7]  
Bejan A., 1984, CONVECTION HEAT TRAN, P157
[8]  
BEJAN A, 1993, HEAT TRANSFER, P331
[9]  
Dally J., 1993, INSTRUMENTATION ENG, P425
[10]  
*FLUID DYN INT EV, 1993, FIDAP THEOR MAN