摘要
Objective: Atrial septal defect (ASD) device closure is routinely done under the guide of transesophageal or intracardiac echocardiography which are expensive techniques and not easily affordable in developing countries. Methods: Using metallic devices, we attempted 32 ASD device closures under transthoracic echocardiography. Findings: Of those, 30 procedures were successful (94 %). In two patients with relatively large ASD we encountered difficulty in positioning the device. These patients were referred for surgical closure. Conclusion: ASD device closure can be carried out successfully in most patients under transthoracic echocardiography in situations where transesophageal or intravenous echocardiographies are not available or affordable.
引用
收藏
页码:473 / 478
页数:6
相关论文
共 21 条
[1]   Erosion of amplatzer septal occluder device after closure of secundum atrial septal defects: Review of registry of complications and recommendations to minimize future risk [J].
Amin, Z ;
Hijazi, ZM ;
Bass, JL ;
Cheatham, JP ;
Hellenbrand, WE ;
Kleinman, CS .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2004, 63 (04) :496-502
[2]  
Behjati M, 2011, IRAN J PEDIATR, V21, P166
[3]   Transcatheter atrial septal defect closure: Modified balloon sizing technique to avoid overstretching the defect and oversizing the Amplatzer septal occluder [J].
Carlson, KM ;
Justino, H ;
O'Brien, RE ;
Dimas, VV ;
Leonard, GT ;
Pignatelli, RH ;
Mullins, CE ;
Smith, EO ;
Grifka, RG .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 66 (03) :390-396
[4]   New technique for device closure of large atrial septal defects [J].
Dalvi, BV ;
Pinto, RJ ;
Gupta, A .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2005, 64 (01) :102-107
[5]  
Dardas PS, 2010, HELL J CARDIOL, V51, P104
[6]   Transcatheter closure of atrial septal defects without fluoroscopy - Feasibility of a new method [J].
Ewert, P ;
Berger, F ;
Daehnert, I ;
van Wees, J ;
Gittermann, M ;
Abdul-Khaliq, H ;
Lange, PE .
CIRCULATION, 2000, 101 (08) :847-849
[7]   Catheter-Based Closure of Atrial Septal Defects in the Oval Fossa With the Amplatzer® Device in Patients in Their First or Second Year of Life [J].
Fischer, G. ;
Smevik, B. ;
Kramer, H. H. ;
Bjornstad, P. G. .
CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2009, 73 (07) :949-955
[8]  
Hijazi Ziyad M, 2003, Heart Lung Circ, V12 Suppl 2, pS63, DOI 10.1046/j.1443-9506.2003.t01-3-.x
[9]   Real-Time Three-Dimensional Transesophageal Echocardiography in Patients with Secundum Atrial Septal Defects: Outcomes following Transcatheter Closure [J].
Johri, Amer M. ;
Witzke, Christian ;
Solis, Jorge ;
Palacios, Igor F. ;
Inglessis, Ignacio ;
Picard, Michael H. ;
Passeri, Jonathan J. .
JOURNAL OF THE AMERICAN SOCIETY OF ECHOCARDIOGRAPHY, 2011, 24 (04) :431-437
[10]   Transthoracic echocardiographic guidance of transcatheter atrial septal defect closure [J].
Kardon, RE ;
Sokoloski, MC ;
Levi, DS ;
Perry, JS ;
Schneider, DJ ;
Allada, V ;
Moore, JW .
AMERICAN JOURNAL OF CARDIOLOGY, 2004, 94 (02) :256-260