Permanent Epicardial Pacing in Pediatric Patients: 12-Year Experience at a Single Center
被引:28
|作者:
Kwak, Jae Gun
Kim, Soo-Jin
Song, Jin Young
Choi, Eun Young
Lee, Sang Yoon
Shim, Woo Sup
Lee, Chang-Ha
Lee, Cheul
Park, Chun Soo
机构:
[1] Sejong Gen Hosp, Dept Thorac & Cardiovasc Surg, Puchon, South Korea
[2] Konkuk Univ, Dept Pediat, Sch Med, Div Pediat Cardiol, Seoul, South Korea
[3] Sejong Gen Hosp, Dept Pediat, Puchon, South Korea
来源:
ANNALS OF THORACIC SURGERY
|
2012年
/
93卷
/
02期
关键词:
CONGENITAL HEART-DISEASE;
PACEMAKER IMPLANTATION;
ENDOCARDIAL LEADS;
LATE RECOVERY;
YOUNG-ADULTS;
FOLLOW-UP;
CHILDREN;
INFANTS;
LONGEVITY;
THERAPY;
D O I:
10.1016/j.athoracsur.2011.09.072
中图分类号:
R5 [内科学];
学科分类号:
1002 ;
100201 ;
摘要:
Background. Permanent cardiac pacing is not often done in children, and when done is usually accomplished through epicardial pacing. We reviewed a 12-year experience with the implantation of epicardial pacemakers by our clinical group. Methods. Fifty-three patients who underwent their first implantation of an epicardial pacemaker before the age of 18 years and between 1997 and 2009 were included in our study. The mean age of the patients at the time of first pacemaker implantation was 5.7 +/- 4.8 years. Indications for pacemaker implantation included postoperative or congenital atrioventricular block and sinus node dysfunction. The patients underwent 105 operations for the replacement of pacemaker pulse generators and 75 operations for the replacement of pacemaker leads. The most commonly used generator mode was the rate-responsive accelerometer-based (DDDR) mode, which was used in 40.9% of the patients. We used more non-steroid-eluting leads (70.1%) than steroid-eluting leads (29.1%). Results. The overall duration of follow-up in the study was 8.0 +/- 4.5 years (range, 2.1 months to approximately 17.0 years). Freedom from the need for generator replacement was 98.0%, 60.7%, and 11.1% at 1, 5, and 8 years, respectively. A tendency toward early generator exhaustion was observed among younger patients (p = 0.058). The generator mode used for pacing did not significantly affect generator longevity. Freedom from the need for lead replacement was 98.3%, 83.8%, and 63.6% at 1, 5, and 10 years, respectively. The mean longevity of the leads used in the study was 10.8 +/- 0.8 years. Neither patient age at the time of lead implantation nor type of lead significantly affected lead longevity. Conclusions. Lead longevity was sufficiently long and did not vary significantly according to type of lead. Generator longevity was not affected by lead type, generator mode, or patient age at the time of pacemaker implantation. (Ann Thorac Surg 2012;93:634-40) (C) 2012 by The Society of Thoracic Surgeons
引用
收藏
页码:634 / 640
页数:7
相关论文