Analysis of oligonucleotides by hydrophilic interaction liquid chromatography coupled to negative ion electrospray ionization mass spectrometry

被引:62
作者
Gong, Lingzhi [1 ]
McCullagh, James S. O. [1 ]
机构
[1] Univ Oxford, Dept Chem, Chem Res Lab, Oxford OX1 3TA, England
关键词
LC/MS; Oligonucleotides; HILIC chromatography; MS friendly buffer; SYNTHETIC OLIGONUCLEOTIDES; CATION-EXCHANGE; ANION-EXCHANGE; NUCLEIC-ACIDS; PERFORMANCE; SEPARATION; DNA; PURIFICATION; PEPTIDES; HPLC;
D O I
10.1016/j.chroma.2011.06.044
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Hydrophilic interaction liquid chromatography (HILIC) is here successfully coupled to negative-ion electrospray ionization time-of-flight mass spectrometry (ESI-TOFMS) for the analysis of synthetic and chemically modified oligonucleotides. Separation was performed on a 2.1 mm x 100mm PEEK ZIC (R) HILIC column packed with hydrophilic stationary phase with a permanent zwitterionic functional group and a particle size of 3.5 mu m with an average pore diameter of 200 angstrom. A method was developed to separate homogeneous and heterogeneous oligonucleotides as well as methylated oligonucleotides using a quaternary pumping system containing ammonium acetate and water with an acetonitrile gradient. Analyses of oligonucleotides were performed by LC/MS with a detection limit of 2.5 picomole (20 mer) with signal to noise ratio (S/N) of 4.12. The influence of the eluent composition, type of buffer and its concentration, and organic modifier were also evaluated. The HILIC LC/MS method presented in this paper used common, 'MS friendly', mobile phases achieving sensitive and selective oligonucleotide analysis. (C) 2011 Elsevier B.V. All rights reserved.
引用
收藏
页码:5480 / 5486
页数:7
相关论文
共 51 条
[1]   Progress and prospects: oligonucleotide-directed gene modification in mouse embryonic stem cells: a route to therapeutic application [J].
Aarts, M. ;
Riele, H. Te .
GENE THERAPY, 2011, 18 (03) :213-219
[2]   HYDROPHILIC-INTERACTION CHROMATOGRAPHY FOR THE SEPARATION OF PEPTIDES, NUCLEIC-ACIDS AND OTHER POLAR COMPOUNDS [J].
ALPERT, AJ .
JOURNAL OF CHROMATOGRAPHY, 1990, 499 :177-196
[3]   Analysis of DNA adducts using high-performance separation techniques coupled to electrospray ionization mass spectrometry [J].
Andrews, CL ;
Vouros, P ;
Harsch, A .
JOURNAL OF CHROMATOGRAPHY A, 1999, 856 (1-2) :515-526
[4]   Detection of T-T Mismatches Using Mass Spectrometry: Specific Interactions of Hg(II) with Oligonucleotides Rich in Thymine (T) [J].
Anichina, Janna ;
Dobrusin, Zoya ;
Bohme, Diethard K. .
JOURNAL OF PHYSICAL CHEMISTRY B, 2010, 114 (46) :15106-15112
[5]  
[Anonymous], 2012, Molecular Cloning: A Laboratory Manual
[6]   Analysis of oligonucleotides by HPLC-electrospray ionization mass spectrometry [J].
Apffel, A ;
Chakel, JA ;
Fischer, S ;
Lichtenwalter, K ;
Hancock, WS .
ANALYTICAL CHEMISTRY, 1997, 69 (07) :1320-1325
[7]   Multiplex Mass Spectrometric Genotyping of Single Nucleotide Polymorphisms Employing Pyrrolidinyl Peptide Nucleic Acid in Combination with Ion-Exchange Capture [J].
Boontha, Boonjira ;
Nakkuntod, Jeerawat ;
Hirankarn, Nattiya ;
Chaumpluk, Piyasak ;
Vilaivan, Tirayut .
ANALYTICAL CHEMISTRY, 2008, 80 (21) :8178-8186
[8]   LIQUID-CHROMATOGRAPHY MASS-SPECTROMETRY OF ANTISENSE OLIGONUCLEOTIDES [J].
BOTHNER, B ;
CHATMAN, K ;
SARKISIAN, M ;
SIUZDAK, G .
BIOORGANIC & MEDICINAL CHEMISTRY LETTERS, 1995, 5 (23) :2863-2868
[9]  
Box HC, 2002, RADIAT RES, V158, P538, DOI 10.1667/0033-7587(2002)158[0538:DACOFL]2.0.CO
[10]  
2