Development of a Gas-Cylinder-Free Plasma Desorption/Ionization System for On-Site Detection of Chemical Warfare Agents

被引:28
作者
Iwai, Takahiro [1 ]
Kakegawa, Ken [2 ]
Aida, Mari [2 ]
Nagashima, Hisayuki [1 ]
Nagoya, Tomoki [1 ]
Kanamori-Kataoka, Mieko [1 ]
Miyahara, Hidekazu [2 ]
Seto, Yasuo [1 ]
Okino, Akitoshi [2 ]
机构
[1] Natl Res Inst Police Sci, Kashiwa, Chiba 2770882, Japan
[2] Tokyo Inst Technol, Dept Energy Sci, Midori Ku, Yokohama, Kanagawa 227, Japan
关键词
MASS-SPECTROMETRIC ANALYSIS; ION MOBILITY SPECTROMETRY; DETECTION PERFORMANCE; OPEN-AIR; IONIZATION; CHROMATOGRAPHY; INSTRUMENT; PRODUCTS; SENSOR; PROBE;
D O I
10.1021/acs.analchem.5b00874
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A gas-cylinder-free plasma desorption/ionization system was developed to realize a mobile on-site analytical device for detection of chemical warfare agents (CWAs). In this system, the plasma source was directly connected to the inlet of a mass spectrometer. The plasma can be generated with ambient air, which is drawn into the discharge region by negative pressure in the mass spectrometer. High-power density pulsed plasma of 100 kW could be generated by using a microhollow cathode and a laboratory-built high-intensity pulsed power supply (pulse width: 10-20 mu s; repetition frequency: 50 Hz). CWAs were desorbed and protonated in the enclosed space adjacent to the plasma source. Protonated sample molecules were introduced to the mass spectrometer by airflow through the discharge region. To evaluate the analytical performance of this device, helium and air plasma were directly irradiated to CWAs in the gas-cylinder-free plasma desorption/ionization system and the protonated molecules were analyzed by using an ion-trap mass spectrometer. A blister agent (nitrogen mustard 3) and nerve gases [cyclohexylsarin (GF), tabun (GA), and O-ethyl S-2-N,N-diisopropylaminoethyl methylphosphonothiolate (VX)] in solution in n-hexane were applied to the Teflon rod and used as test samples, after solvent evaporation. As a result, protonated molecules of CWAs were successfully observed as the characteristic ion peaks at m/z 204, 181, 163, and 268, respectively. In air plasma, the limits of detection were estimated to be 22, 20, 4.8, and 1.0 pmol, respectively, which were lower than those obtained with helium plasma. To achieve quantitative analysis, calibration curves were made by using CWA stimulant dipinacolyl methylphosphonate as an internal standard; straight correlation lines (R-2 = 0.9998) of the peak intensity ratios (target per internal standard) were obtained. Remarkably, GA and GF gave protonated dimer ions, and the ratios of the protonated dimer ions to the protonated monomers increased with the amount of GA and GF applied.
引用
收藏
页码:5707 / 5715
页数:9
相关论文
共 57 条
[1]   Ion mobility spectrometry: Arriving on site and moving beyond a low profile [J].
Baumbach, JI ;
Eiceman, GA .
APPLIED SPECTROSCOPY, 1999, 53 (09) :338A-355A
[2]   Demonstration of spread-on peel-off consumer products for sampling surfaces contaminated with pesticides and chemical warfare agent signatures [J].
Behringer, Deborah L. ;
Smith, Deborah L. ;
Katona, Vanessa R. ;
Lewis, Alan T., Jr. ;
Hernon-Kenny, Laura A. ;
Crenshaw, Michael D. .
FORENSIC SCIENCE INTERNATIONAL, 2014, 241 :7-14
[3]   Elucidation of Reaction Mechanisms Responsible for Afterglow and Reagent-Ion Formation in the Low-Temperature Plasma Probe Ambient Ionization Source [J].
Chan, George C. -Y. ;
Shelley, Jacob T. ;
Wiley, Joshua S. ;
Engelhard, Carsten ;
Jackson, Ayanna U. ;
Cooks, R. Graham ;
Hieftje, Gary M. .
ANALYTICAL CHEMISTRY, 2011, 83 (10) :3675-3686
[4]   Versatile new ion source for the analysis of materials in open air under ambient conditions [J].
Cody, RB ;
Laramée, JA ;
Durst, HD .
ANALYTICAL CHEMISTRY, 2005, 77 (08) :2297-2302
[5]   Hand-Portable Gas Chromatograph-Toroidal Ion Trap Mass Spectrometer (GC-TMS) for Detection of Hazardous Compounds [J].
Contreras, Jesse A. ;
Murray, Jacolin A. ;
Tolley, Samuel E. ;
Oliphant, Joseph L. ;
Tolley, H. Dennis ;
Lammert, Stephen A. ;
Lee, Edgar D. ;
Later, Douglas W. ;
Lee, Milton L. .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2008, 19 (10) :1425-1434
[6]   Ion mobility spectrometry rediscovered [J].
Cottingham, K .
ANALYTICAL CHEMISTRY, 2003, 75 (19) :435A-439A
[7]   Liquid chromatography electrospray tandem mass spectrometric and desorption electrospray ionization tandem mass spectrometric analysis of chemical warfare agents in office media typically collected during a forensic investigation [J].
D'Agostino, PA ;
Hancock, JR ;
Chenier, CL ;
Lepage, CRJ .
JOURNAL OF CHROMATOGRAPHY A, 2006, 1110 (1-2) :86-94
[8]   Desorption electrospray ionisation mass spectrometric analysis of chemical warfare agents from solid-phase microextraction fibers [J].
D'Agostino, Paul A. ;
Chenier, Claude L. ;
Hancock, James R. ;
Lepage, Carmela R. Jackson .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2007, 21 (04) :543-549
[9]   DESI-MS/MS of Chemical Warfare Agents and Related Compounds [J].
D'Agostino, Paul A. .
DETECTION OF BIOLOGICAL AGENTS FOR THE PREVENTION OF BIOTERRORISM, 2010, :163-179
[10]   Desorption electrospray ionization mass spectrometric analysis of organophosphorus chemical warfare agents using ion mobility and tandem mass spectrometry [J].
D'Agostino, Paul A. ;
Chenier, Claude L. .
RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2010, 24 (11) :1617-1624