Upgrade of gamma electron vertex imaging system for high-performance range verification in pencil beam scanning proton therapy

被引:7
作者
Kim, Sung Hun [1 ]
Jeong, Jong Hwi [1 ]
Ku, Youngmo [2 ]
Jung, Jaerin [2 ]
Cho, Sungkoo [3 ]
Jo, Kwanghyun [3 ]
Kim, Chan Hyeong [2 ]
机构
[1] Natl Canc Ctr, Ctr Proton Therapy, Goyang Si 10408, Gyeonggi Do, South Korea
[2] Hanyang Univ, Dept Nucl Engn, 222 Wangsimni Ro, Seoul 04763, South Korea
[3] Samsung Med Ctr, Radiat Oncol, Seoul 06351, South Korea
关键词
Prompt gamma imaging; Gamma electron vertex imaging; In-vivo range verification; Pencil beam scanning proton therapy; Proton therapy;
D O I
10.1016/j.net.2021.09.001
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
In proton therapy, a highly conformal proton dose can be delivered to the tumor by means of the steep distal dose penumbra at the end of the beam range. The proton beam range, however, is highly sensitive to range uncertainty, which makes accurately locating the proton range in the patient difficult. In-vivo range verification is a method to manage range uncertainty, one of the promising techniques being prompt gamma imaging (PGI). In earlier studies, we proposed gamma electron vertex imaging (GEVI), and constructed a proof-of-principle system. The system successfully demonstrated the GEVI imaging principle for therapeutic proton pencil beams without scanning, but showed some limitations under clinical conditions, particularly for pencil beam scanning proton therapy. In the present study, we upgraded the GEVI system in several aspects and tested the performance improvements such as for range-shift verification in the context of line scanning proton treatment. Specifically, the system showed better performance in obtaining accurate prompt gamma (PG) distributions in the clinical environment. Furthermore, high shift-detection sensitivity and accuracy were shown under various range-shift conditions using line scanning proton beams. (c) 2021 Korean Nuclear Society, Published by Elsevier Korea LLC. This is an open access article under the CC BY-NC-ND license (http://creativecommons.org/licenses/by-nc-nd/4.0/).
引用
收藏
页码:1016 / 1023
页数:8
相关论文
共 15 条
  • [1] Gamma electron vertex imaging for in-vivo beam-range measurement in proton therapy: Experimental results
    Kim, Chan Hyeong
    Lee, Han Rim
    Kim, Sung Hun
    Park, Jong Hoon
    Cho, Sungkoo
    Jung, Won Gyun
    [J]. APPLIED PHYSICS LETTERS, 2018, 113 (11)
  • [2] Gamma electron vertex imaging and application to beam range verification in proton therapy
    Kim, Chan Hyeong
    Park, Jin Hyung
    Seo, Hee
    Lee, Han Rim
    [J]. MEDICAL PHYSICS, 2012, 39 (02) : 1001 - 1005
  • [3] In vivo proton range verification: a review
    Knopf, Antje-Christin
    Lomax, Antony
    [J]. PHYSICS IN MEDICINE AND BIOLOGY, 2013, 58 (15) : 131 - 160
  • [4] Prompt-gamma monitoring in hadrontherapy: A review
    Krimmer, J.
    Dauvergne, D.
    Letang, J. M.
    Testa, E.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2018, 878 : 58 - 73
  • [5] Collimated prompt gamma TOF measurements with multi-slit multi-detector configurations
    Krimmer, J.
    Chevallier, M.
    Constanzo, J.
    Dauvergne, D.
    De Rydt, M.
    Dedes, G.
    Freud, N.
    Henriquet, P.
    La Tessa, C.
    Letang, J. M.
    Pleskac, R.
    Pinto, M.
    Ray, C.
    Reithinger, V.
    Richard, M. H.
    Rinaldi, I.
    Roellinghoff, F.
    Schuy, C.
    Testa, E.
    Testa, M.
    [J]. JOURNAL OF INSTRUMENTATION, 2015, 10
  • [6] Prototype system for proton beam range measurement based on gamma electron vertex imaging
    Lee, Han Rim
    Kim, Sung Hun
    Park, Jong Hoon
    Jung, Won Gyun
    Lim, Hansang
    Kim, Chan Hyeong
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2017, 857 : 82 - 97
  • [7] Development of array-type prompt gamma measurement system for in vivo range verification in proton therapy
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    Lee, Se Byeong
    [J]. MEDICAL PHYSICS, 2012, 39 (04) : 2100 - 2107
  • [8] TWO-DIMENSIONAL PROMPT GAMMA MEASUREMENT SIMULATION FOR IN VIVO DOSE VERIFICATION IN PROTON THERAPY: A MONTE CARLO STUDY
    Min, Chul Hee
    Lee, Han Rim
    Kim, Chan Hyeong
    [J]. NUCLEAR TECHNOLOGY, 2011, 175 (01) : 11 - 15
  • [9] Prompt gamma measurements for locating the dose falloff region in the proton therapy
    Min, Chul-Hee
    Kim, Chan Hyeong
    Youn, Min-Young
    Kim, Jong-Won
    [J]. APPLIED PHYSICS LETTERS, 2006, 89 (18)