Determination of Morphine in Human Urine by the Novel Competitive Fluorescence Immunoassay

被引:10
作者
Cao, Jie [1 ,2 ,3 ,4 ]
Chen, Xiao-Ying [5 ]
Zhao, Wu-Rong [4 ]
机构
[1] Fujian Agr & Forestry Univ, Coll Life Sci, Fuzhou 350002, Fujian, Peoples R China
[2] Fujian Police Coll, Sci Res & Expt Ctr, Fuzhou 350007, Fujian, Peoples R China
[3] Fujian Entry Exit Inspect & Quarantine Bur PRC, AQSIQ Key Lab Drug Detect, Fujian Int Travel Healthcare Ctr, Fuzhou 350001, Fujian, Peoples R China
[4] Fujian HuaMin Forens Ctr, Quanzhou 362000, Peoples R China
[5] Fuzhou Univ, Coll Environm & Resource, Fuzhou 350116, Fujian, Peoples R China
关键词
LIQUID-CHROMATOGRAPHIC DETERMINATION; GLASSY-CARBON ELECTRODE; HUMAN PLASMA; 6-GLUCURONIDE METABOLITES; GAS-CHROMATOGRAPHY; CODEINE; 6-ACETYLMORPHINE; HEROIN; BLOOD; GLUCURONIDES;
D O I
10.1155/2019/7826090
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A competitive fluorescence immunoassay for the identification and quantification of morphine has been developed on the basis of hapten-coated plate format. Hapten was prepared through covalent conjugating a morphine derivative with albumin bovine. In the immunoassay, the hapten was inoculated on a 96-well plate and then bound with monoclonal antibodies labeled with a signal indicating dye, fluorescein isothiocyanate (FITC). Unbound FITC-antibodies were rinsed off from the plate. The fluorescein intensity decreases in the presence of morphine molecules due to the competitively binding to antibodies against hapten. The intensity is inversely correlated with the concentration of morphine. In quantitative analysis for urine samples, we obtained a linearity range of 0.2g/mL approximate to 2.5g/mL, along with a detection limit of c.a. 1ng/mL. The fluorescence immunoassay shows low cross-reactivity (below 10%) to 6-acetylmorphine, 3-acetylmorphine, and heroine. The developed method produced comparable results to the standard GC-MS/MS method. In conclusion, a rapid and efficient screening tool for morphine in clinical human urine has been established.
引用
收藏
页数:11
相关论文
共 37 条
[1]   Determination of heroin metabolites in human urine using capillary zone electrophoresis with β-cyclodextrin and UV detection [J].
Alnajjar, A ;
McCord, B .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2003, 33 (03) :463-473
[2]  
[Anonymous], 1986, Cancer Pain Relief
[3]   LC determination of morphine and morphine glucuronides in human plasma by coulometric and UV detection [J].
Ary, K ;
Róna, K .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2001, 26 (02) :179-187
[4]   Morphine metabolites [J].
Christrup, LL .
ACTA ANAESTHESIOLOGICA SCANDINAVICA, 1997, 41 (01) :116-122
[5]   Simultaneous determination of in total 17 opium alkaloids and opioids in blood and urine by fast liquid chromatography-diode-array detection-fluorescence detection, after solid-phase extraction [J].
Dams, R ;
Benijts, T ;
Lambert, WE ;
De Leenheer, AP .
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2002, 773 (01) :53-61
[6]   Method for quantification of morphine and its 3-and 6-glucuronides, codeine, codeine glucuronide and 6-monoacetylmorphine in human blood by liquid chromatography-electrospray mass spectrometry for routine analysis in forensic toxicology [J].
Dienes-Nagy, A ;
Rivier, L ;
Giroud, C ;
Augsburger, M ;
Mangin, P .
JOURNAL OF CHROMATOGRAPHY A, 1999, 854 (1-2) :109-118
[7]   Development of miniaturized competitive immunoassays on a protein chip as a screening tool for drugs [J].
Du, HW ;
Wu, MT ;
Yang, WP ;
Yuan, G ;
Sun, YM ;
Lu, Y ;
Zhao, S ;
Du, QY ;
Wang, F ;
Yan, S ;
Pan, M ;
Lu, Y ;
Wang, S ;
Cheng, J .
CLINICAL CHEMISTRY, 2005, 51 (02) :368-375
[8]   Determination of heroin, 6-acetylmorphine, and morphine in biological fluids using their propionyl derivatives with ion trap GC-MS [J].
Guillot, JG ;
Lefebvre, M ;
Weber, JP .
JOURNAL OF ANALYTICAL TOXICOLOGY, 1997, 21 (02) :127-133
[9]   Exploiting sequential injection analysis technique to automate on-line sample treatment and quantitative determination of morphine in human urine [J].
Idris, Abubakr M. ;
Alnajjar, Ahmed O. .
TALANTA, 2008, 77 (02) :522-526
[10]   VOLTAMMETRIC BEHAVIOR OF MORPHINE AT A GLASSY-CARBON ELECTRODE AND ITS DETERMINATION IN HUMAN SERUM BY LIQUID-CHROMATOGRAPHY WITH ELECTROCHEMICAL DETECTION UNDER BASIC CONDITIONS [J].
JORDAN, PH ;
HART, JP .
ANALYST, 1991, 116 (10) :991-996